Non-enzymatic glucose detection with screen-printed chemiresistive sensor using green synthesised silver nanoparticle and multi-walled carbon nanotubes-zinc oxide nanofibers

被引:3
|
作者
Zalke, Jitendra B. [1 ]
Narkhede, N. P. [2 ]
Pandhurnekar, C. P. [3 ]
Rotake, Dinesh R. [4 ]
Singh, Shiv Govind [4 ]
机构
[1] Shri Ramdeobaba Coll Engn & Management, Dept Elect Design Technol, Nagpur, India
[2] Shri Ramdeobaba Coll Engn & Management, Dept Elect Engn, Nagpur, India
[3] Shri Ramdeobaba Coll Engn & Management, Dept Chem, Nagpur, India
[4] Indian Inst Technol, Dept Elect Engn, Hyderabad, India
关键词
MWCNT-ZnO nanofibers; screen printed chemiresistive interdigitated electrodes (SPCIE); glucose sensor; green synthesized silver nanoparticles (AgNPs); conductive porous natural binder layer (CPNBL); INDICA LEAF EXTRACT; AQUEOUS EXTRACT; CARDIOVASCULAR-DISEASE; BIOMIMETIC SYNTHESIS; BIOSYNTHESIS; ELECTRODES; BIOSENSOR; ANTIBACTERIAL; PLATFORM; IMPACT;
D O I
10.1088/1361-6528/ad090c
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Non-enzymatic screen-printed chemiresistive interdigitated electrodes (SPCIE) were designed and fabricated using a low-cost screen-printing method for detection of the glucose. The interdigitated electrodes (IDE) pattern was printed using conductive graphene ink on the glossy surface of the photo paper. The proposed glossy photo paper-based SPCIE are functionalized with multi-walled carbon nanotubes-zinc oxide (MWCNTs-ZnO) nanofibers to create the chemiresistive matrix. Further, to bind these nanofibers with the graphene electrode surface, we have used the green synthesized silver nanoparticles (AgNPs) with banana flower stem fluid (BFSF) as a binder solution. AgNPs with BFSF form the conductive porous natural binder layer (CPNBL). It does not allow to increase the resistivity of the deposited material on graphene electrodes and also keeps the nanofibers intact with paper-based SPCIE. The synthesized material of MWCNT-ZnO nanofibers and green synthesized AgNPs with BFSF as a binder were characterized by Ultraviolet-visible spectroscopy (UV-vis), scanning electron microscope (SEM), x-ray diffraction (XRD), and Fourier-transform infrared spectroscopy (FTIR). The amperometric measurements were performed on the proposed SPCIE sensor to detect the glucose sample directly. The innovative paper-based SPCIE glucose sensor exhibits a linear corelation between current measurements and glucose concentration in the range between 45.22 mu m and 20 mm, with a regression coefficient (R 2) of 0.9902 and a lower limit of detection (LoD) of 45.22 mu m (n = 5). The sensitivity of the developed SPCIE sensor was 2178.57 mu AmM-1cm-2, and the sensor's response time determined was approximately equal to 18 s. The proposed sensor was also tested for real blood serum sample, and relative standard deviation (RSD) was found equal to 2.95%.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Green Fabrication of Nonenzymatic Glucose Sensor Using Multi-Walled Carbon Nanotubes Decorated with Copper (II) Oxide Nanoparticles for Tear Fluid Analysis
    Zahra Asgari Kheirabadi
    Mohsen Rabbani
    Marzieh Samiei Foroushani
    Applied Biochemistry and Biotechnology, 2022, 194 : 3689 - 3705
  • [42] Evaluation of the electrochemical response of Saccharomyces cerevisiae using screen-printed carbon electrodes (SPCE) modified with oxidized multi-walled carbon nanotubes dispersed in water - Nafion®
    Acevedo-Restrepo, Isabel
    Blandon-Naranjo, Lucas
    Victor Vazquez, Mario
    Restrepo-Sanchez, Nora
    CURRENT RESEARCH IN FOOD SCIENCE, 2023, 6
  • [43] Non-Enzymatic Electrochemical Detection of Glucose by Mixed-Valence Cobalt Containing Keggin Polyoxometalate/Multi-Walled Carbon Nanotube Composite
    Ayranci, Rukiye
    Torlak, Yasemin
    Ak, Metin
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (04) : B205 - B211
  • [44] A novel amperometric sensor based on screen-printed electrode modified with multi-walled carbon nanotubes and molecularly imprinted membrane for rapid determination of ractopamine in pig urine
    Zhang, Hongcai
    Liu, Guoyan
    Chai, Chunyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 168 : 103 - 110
  • [45] Novel electrochemical non-enzymatic glucose sensor based on 3D Au@Pt core-shell nanoparticles decorated graphene oxide/multi-walled carbon nanotubes composite
    Wang, Ruru
    Liu, Xuerui
    Zhao, Yiwei
    Qin, Jianhua
    Xu, Hui
    Dong, Lina
    Gao, Shanmin
    Zhong, Linlin
    MICROCHEMICAL JOURNAL, 2022, 174
  • [46] Manufacture of Lead-Specific Screen-Printed Sensor Based on Lead Schiff Base Complex as Carrier and Multi-Walled Carbon Nanotubes for Detection of Pb(II) in Contaminated Water Tests
    Ali, Tamer Awad
    Hassan, Abeer M. E.
    Mohamed, Gehad G.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (12): : 10732 - 10747
  • [47] An amperometric non-enzymatic glucose sensor by electrodepositing copper nanocubes onto vertically well-aligned multi-walled carbon nanotube arrays
    Yang, Jiang
    Zhang, Wei-De
    Gunasekaran, Sundaram
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (01): : 279 - 284
  • [48] An enzymatic histamine biosensor based on a screen-printed carbon electrode modified with a chitosan-gold nanoparticles composite cryogel on Prussian blue-coated multi-walled carbon nanotubes
    Nontipichet, Natha
    Khumngern, Suntisak
    Choosang, Jittima
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    FOOD CHEMISTRY, 2021, 364
  • [49] Smartphone-based electrochemical system with multi-walled carbon nanotubes/thionine/gold nanoparticles modified screen-printed immunosensor for cancer antigen 125 detection
    Fan, Yan
    Shi, Shengyu
    Ma, Junshuang
    Guo, Yaohua
    MICROCHEMICAL JOURNAL, 2022, 174
  • [50] A highly sensitive non-enzymatic glucose sensor based on a simple two-step electrodeposition of cupric oxide (CuO) nanoparticles onto multi-walled carbon nanotube arrays
    Yang, Jiang
    Jiang, Liao-Chuan
    Zhang, Wei-De
    Gunasekaran, Sundaram
    TALANTA, 2010, 82 (01) : 25 - 33