Non-enzymatic glucose detection with screen-printed chemiresistive sensor using green synthesised silver nanoparticle and multi-walled carbon nanotubes-zinc oxide nanofibers

被引:3
|
作者
Zalke, Jitendra B. [1 ]
Narkhede, N. P. [2 ]
Pandhurnekar, C. P. [3 ]
Rotake, Dinesh R. [4 ]
Singh, Shiv Govind [4 ]
机构
[1] Shri Ramdeobaba Coll Engn & Management, Dept Elect Design Technol, Nagpur, India
[2] Shri Ramdeobaba Coll Engn & Management, Dept Elect Engn, Nagpur, India
[3] Shri Ramdeobaba Coll Engn & Management, Dept Chem, Nagpur, India
[4] Indian Inst Technol, Dept Elect Engn, Hyderabad, India
关键词
MWCNT-ZnO nanofibers; screen printed chemiresistive interdigitated electrodes (SPCIE); glucose sensor; green synthesized silver nanoparticles (AgNPs); conductive porous natural binder layer (CPNBL); INDICA LEAF EXTRACT; AQUEOUS EXTRACT; CARDIOVASCULAR-DISEASE; BIOMIMETIC SYNTHESIS; BIOSYNTHESIS; ELECTRODES; BIOSENSOR; ANTIBACTERIAL; PLATFORM; IMPACT;
D O I
10.1088/1361-6528/ad090c
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Non-enzymatic screen-printed chemiresistive interdigitated electrodes (SPCIE) were designed and fabricated using a low-cost screen-printing method for detection of the glucose. The interdigitated electrodes (IDE) pattern was printed using conductive graphene ink on the glossy surface of the photo paper. The proposed glossy photo paper-based SPCIE are functionalized with multi-walled carbon nanotubes-zinc oxide (MWCNTs-ZnO) nanofibers to create the chemiresistive matrix. Further, to bind these nanofibers with the graphene electrode surface, we have used the green synthesized silver nanoparticles (AgNPs) with banana flower stem fluid (BFSF) as a binder solution. AgNPs with BFSF form the conductive porous natural binder layer (CPNBL). It does not allow to increase the resistivity of the deposited material on graphene electrodes and also keeps the nanofibers intact with paper-based SPCIE. The synthesized material of MWCNT-ZnO nanofibers and green synthesized AgNPs with BFSF as a binder were characterized by Ultraviolet-visible spectroscopy (UV-vis), scanning electron microscope (SEM), x-ray diffraction (XRD), and Fourier-transform infrared spectroscopy (FTIR). The amperometric measurements were performed on the proposed SPCIE sensor to detect the glucose sample directly. The innovative paper-based SPCIE glucose sensor exhibits a linear corelation between current measurements and glucose concentration in the range between 45.22 mu m and 20 mm, with a regression coefficient (R 2) of 0.9902 and a lower limit of detection (LoD) of 45.22 mu m (n = 5). The sensitivity of the developed SPCIE sensor was 2178.57 mu AmM-1cm-2, and the sensor's response time determined was approximately equal to 18 s. The proposed sensor was also tested for real blood serum sample, and relative standard deviation (RSD) was found equal to 2.95%.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Non-enzymatic glucose detection using Ni/multi-walled carbon nanotubes composite
    Zhang, Xiaojun
    Wang, Guangfeng
    Huang, Yan
    Yu, Liutao
    Fang, Bin
    MICRO & NANO LETTERS, 2012, 7 (02): : 168 - 170
  • [2] Non-enzymatic glucose sensor and photocurrent performance of zinc oxide quantum dots supported multi-walled carbon nanotubes
    Vinoth, Victor
    Subramaniyam, Gowrishankar
    Anandan, Sambandam
    Valdes, Hector
    Manidurai, Paulraj
    MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2021, 265
  • [3] Non-enzymatic analysis of glucose on printed films based on multi-walled carbon nanotubes
    Nikos G. Tsierkezos
    Uwe Ritter
    Nora Wetzold
    Arved Carl Hübler
    Microchimica Acta, 2012, 179 : 157 - 161
  • [4] Non-enzymatic analysis of glucose on printed films based on multi-walled carbon nanotubes
    Tsierkezos, Nikos G.
    Ritter, Uwe
    Wetzold, Nora
    Huebler, Arved Carl
    MICROCHIMICA ACTA, 2012, 179 (1-2) : 157 - 161
  • [5] Non-Enzymatic Amperometric Glucose Biosensor from Zinc Oxide Nanoparticles Decorated Multi-Walled Carbon Nanotubes
    Baby, Tessy Theres
    Ramaprabhu, S.
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2011, 11 (06) : 4684 - 4691
  • [6] Multi-walled carbon nanotubes modified screen-printed electrodes for cisplatin detection
    Materon, Elsa M.
    Wong, Ademar
    Klein, Stanlei I.
    Liu, Juewen
    Sotomayor, Maria D. P. T.
    ELECTROCHIMICA ACTA, 2015, 158 : 271 - 276
  • [7] Rapid detection of ssDNA and RNA using multi-walled carbon nanotubes modified screen-printed carbon electrode
    Ye, YK
    Ju, HX
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (05): : 735 - 741
  • [8] Electrostatically functionalized multi-walled carbon nanotubes based flexible and non-enzymatic biosensor for glucose detection
    Singh, Bhawana
    Bhatia, Vasuda
    Jain, V.K.
    Sensors and Transducers, 2012, 146 (11): : 69 - 77
  • [9] Rapid voltammetric detection of kojic acid at a multi-walled carbon nanotubes screen-printed electrode
    Buleandra, Mihaela
    Rabinca, Andreea Alexandra
    Tache, Florentin
    Moldovan, Zenovia
    Stamatin, Joan
    Mihailciuc, Constantin
    Ciucu, Anton Alexandru
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 406 - 412
  • [10] Multi-walled Carbon Nanotubes Modified Screen-Printed Electrode Coated Bismuth Oxide Nanoparticle for Rapid Detection of Cd(II) and Pb(II)
    Cui, Hao
    Li, Qingde
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (07): : 6154 - 6167