Influence of oversimplifying the head anatomy on cerebral blood flow measurements with diffuse correlation spectroscopy

被引:6
|
作者
Zhao, Hongting [1 ,2 ]
Buckley, Erin M. [1 ,2 ,3 ,4 ]
机构
[1] Georgia Inst Technol, Atlanta, GA 30332 USA
[2] Emory Univ, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30322 USA
[3] Emory Univ, Sch Med, Dept Pediat, Atlanta, GA 30322 USA
[4] Childrens Healthcare Atlanta, Atlanta, GA 30303 USA
基金
美国国家卫生研究院;
关键词
cerebral blood flow; diffuse correlation spectroscopy; multilayer model; INFRARED LIGHT-PROPAGATION; SCATTERING; BRAIN; THICKNESS; FLUID; SCALP; MODEL; MRI;
D O I
10.1117/1.NPh.10.1.015010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Significance: Diffuse correlation spectroscopy (DCS) is an emerging optical modality for noninvasive assessment of an index of regional cerebral blood flow. By the nature of this noninvasive measurement, light must pass through extracerebral layers (i.e., skull, scalp, and cerebral spinal fluid) before detection at the tissue surface. To minimize the contribution of these extracerebral layers to the measured signal, an analytical model has been developed that treats the head as a series of three parallel and infinitely extending slabs (mimicking scalp, skull, and brain). The threelayer model has been shown to provide a significant improvement in cerebral blood flow estimation over the typically used model that treats the head as a bulk homogenous medium. However, the three-layer model is still a gross oversimplification of the head geometry that ignores head curvature, the presence of cerebrospinal fluid (CSF), and heterogeneity in layer thickness. Aim: Determine the influence of oversimplifying the head geometry on cerebral blood flow estimated with the three-layer model. Approach: Data were simulated with Monte Carlo in a four-layer slab medium and a three-layer sphere medium to isolate the influence of CSF and curvature, respectively. Additionally, simulations were performed on magnetic resonance imaging (MRI) head templates spanning a wide-range of ages. Simulated data were fit to both the homogenous and three-layer model for CBF. Finally, to mitigate the errors in potential CBF estimation due to the difficulty in defining layer thickness, we investigated an approach to identify an equivalent, "optimized" thickness via a pressure modulation. Results: Both head curvature and failing to account for CSF lead to significant errors in the estimation of CBF. However, the effect of curvature and CSF on relative changes in CBF is minimal. Further, we found that CBF was underestimated in all MRI-templates, although the magnitude of these underestimations was highly influenced by small variations in the source and detector optode positioning. The optimized thickness obtained from pressure modulation did not improve estimation accuracy of CBF, although it did significantly improve the estimation accuracy of relative changes in CBF. Conclusions: In sum, these findings suggest that the three-layer model holds promise for improving estimation of relative changes in cerebral blood flow; however, estimations of absolute cerebral blood flow with the approach should be viewed with caution given that it is difficult to account for appreciable sources of error, such as curvature and CSF.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Experimental Validation of Microvasculature Blood Flow Modeling by Diffuse Correlation Spectroscopy
    Zhu, Yanwen
    Gui, Zhiguo
    Xue, Bing
    Shang, Yu
    IEEE ACCESS, 2020, 8 : 15945 - 15951
  • [43] Validation of diffuse correlation spectroscopy measurements of rodent cerebral blood flow with simultaneous arterial spin labeling MRI; towards MRI-optical continuous cerebral metabolic monitoring
    Carp, S. A.
    Dai, G. P.
    Boas, D. A.
    Franceschini, M. A.
    Kim, Y. R.
    BIOMEDICAL OPTICS EXPRESS, 2010, 1 (02): : 553 - 565
  • [44] CORRELATION OF CEREBRAL BLOOD-FLOW WITH OUTCOME IN HEAD INJURED PATIENTS
    LANGFITT, TW
    OBRIST, WD
    GENNARELLI, TA
    OCONNOR, MJ
    TERWEEME, CA
    ANNALS OF SURGERY, 1977, 186 (04) : 411 - 414
  • [45] Noncontact diffuse correlation spectroscopy for noninvasive deep tissue blood flow measurement
    Lin, Yu
    He, Lian
    Shang, Yu
    Yu, Guoqiang
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (01)
  • [46] Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle
    Li, Zhe
    Baker, Wesley B.
    Parthasarathy, Ashwin B.
    Ko, Tiffany S.
    Wang, Detian
    Schenkel, Steven
    Durduran, Turgut
    Li, Gang
    Yodh, Arjun G.
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (12)
  • [47] Dynamic measurements of absolute cerebral blood flow with coherent hemodynamics spectroscopy
    Thao Pham
    Sassaroli, Angelo
    Blaney, Giles
    Fantini, Sergio
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE XIII, 2019, 10874
  • [48] Quantitative measurements of cerebral blood flow with near-infrared spectroscopy
    Pham, Thao
    Tgavalekos, Kristen
    Sassaroli, Angelo
    Blaney, Giles
    Fantini, Sergio
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (04) : 2117 - 2134
  • [49] Quantification of blood flow and oxygen saturation based on multiwavelength diffuse correlation spectroscopy
    Li, Zhe
    Jiang, Minnan
    Feng, Jinchao
    Jia, Kebin
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS XI, 2021, 11900
  • [50] Coherent Hemodynamics Spectroscopy for Dynamic Measurements of Absolute Cerebral Blood Flow
    Pham, Thao
    Tgavalekos, Kristen
    Sassaroli, Angelo
    Fantini, Sergio
    7TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM (BME7): TRANSLATIONAL HEALTH SCIENCE AND TECHNOLOGY FOR DEVELOPING COUNTRIES, 2020, 69 : 375 - 378