Reliability and validity of pose estimation algorithm for measurement of knee range of motion after total knee arthroplasty

被引:3
|
作者
Saiki, Y. [1 ,2 ,3 ]
Kabata, T. [1 ]
Ojima, T. [1 ,4 ]
Kajino, Y. [1 ]
Kubo, N. [1 ,5 ]
Tsuchiya, H. [1 ]
机构
[1] Fukui Gen Hosp, Fukui, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Kanazawa, Japan
[3] Fukui Hlth Sci Univ, Fac Hlth Sci, Dept Rehabil Phys Therapy, Fukui, Japan
[4] Fukui Gen Hosp, Dept Orthopaed Surg, Fukui, Japan
[5] Fukui Gen Hosp, Dept Rehabil Phys Therapy, Fukui, Japan
来源
BONE & JOINT RESEARCH | 2023年 / 12卷 / 05期
关键词
Pose estimation; Reliability; Validity; Knee range of motion; Total knee arthroplasty; GONIOMETRIC MEASUREMENTS; ANALYSIS SYSTEMS; TRACKING; FLEXION; VERIFICATION; KINEMATICS; AGREEMENT;
D O I
10.1302/2046-3758.125.BJR-2022-0257.R1
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Aims We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry. Methods In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland-Altman analyses to evaluate the agreement and error be-tween radiography and the other measurements. Results OpenPose had excellent test-retest reliability (intraclass correlation coefficient (1,1) = 1.000). The R-2 of all regression models indicated large correlations (0.747 to 0.927). In the flexion position, the intraclass correlation coefficients (2,1) of OpenPose indicated excellent agreement (0.953) with radiography. In the extension position, the intraclass correlation coefficients (2,1) indicated good agreement of OpenPose and radiography (0.815) and moderate agreement of goniometry with radiography (0.593). OpenPose had no systematic error in the flexion position, and a 2.3 degrees fixed error in the extension position, compared to radiography. Conclusion OpenPose is a reliable and valid tool for measuring flexion and extension positions after TKA. It has better accuracy than goniometry, especially in the extension position. Accurate measurement values can be obtained with low error, high reproducibility, and no contact, independent of the examiner's skills.
引用
下载
收藏
页码:313 / 320
页数:8
相关论文
共 50 条
  • [21] RELIABILITY AND VALIDITY OF THE DUTCH IPAQ IN PATIENTS AFTER TOTAL HIP AND KNEE ARTHROPLASTY
    Stevens, M.
    Blikman, T.
    Bulstra, S. K.
    Van denAkker-Scheek, L.
    Reininga, I. H. F.
    INTERNATIONAL JOURNAL OF BEHAVIORAL MEDICINE, 2014, 21 : S101 - S102
  • [22] Patella Eversion Reduces Early Knee Range of Motion and Muscle Torque Recovery after Total Knee Arthroplasty: Comparison between Minimally Invasive Total Knee Arthroplasty and Conventional Total Knee Arthroplasty
    Majima, Tokifumi
    Nishiike, Osamu
    Sawaguchi, Naohiro
    Susuda, Kouichi
    Minami, Akio
    ARTHRITIS, 2011,
  • [23] Restricted motion after total knee arthroplasty
    Kucera, T.
    Urban, K.
    Karpas, K.
    Sponer, P.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2007, 74 (05) : 326 - 331
  • [24] Motion analysis after total knee arthroplasty
    Sosio C.
    Gatti R.
    Corti M.
    Locatelli E.
    Fraschini G.
    Sport Sciences for Health, 2008, 4 (1-2) : 1 - 6
  • [25] Responsiveness, Reliability, and Validity of Arabic Version of Oxford Knee Score for Total Knee Arthroplasty
    Bin Sheeha, Bodor
    Williams, Anita
    Johnson, David Sands
    Granat, Malcolm
    Bin Nasser, Ahmad
    Jones, Richard
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2020, 102 (15): : E89
  • [26] Correction of Patellar Bone Deviation on the Range of Motion after Total Knee Arthroplasty
    Pirmohammadi, Hossein
    Maybodi, Mohamad Kazem Emami
    Shakerisefat, Alireza
    TRAUMA MONTHLY, 2023, 28 (02) : 794 - 803
  • [27] Predicting Functional Performance and Range of Motion Outcomes After Total Knee Arthroplasty
    Bade, Michael J.
    Kittelson, John M.
    Kohrt, Wendy M.
    Stevens-Lapsley, Jennifer E.
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2014, 93 (07) : 579 - 585
  • [28] Limited range of motion after total knee arthroplasty: Etiology, treatment, and prognosis
    Papagelopoulos, PJ
    Sim, FH
    ORTHOPEDICS, 1997, 20 (11) : 1061 - 1065
  • [29] The effect of posterior tibial slope on range of motion after total knee arthroplasty
    Kansara, Devanshu
    Markel, David C.
    JOURNAL OF ARTHROPLASTY, 2006, 21 (06): : 809 - 813
  • [30] Outpatient Physiotherapy Did Not Improve Range of Motion After Total Knee Arthroplasty
    Bjorgul, Kristian
    Novicoff, Wendy M.
    Saleh, Khaled J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08): : 2011 - 2011