Reliability and validity of pose estimation algorithm for measurement of knee range of motion after total knee arthroplasty

被引:3
|
作者
Saiki, Y. [1 ,2 ,3 ]
Kabata, T. [1 ]
Ojima, T. [1 ,4 ]
Kajino, Y. [1 ]
Kubo, N. [1 ,5 ]
Tsuchiya, H. [1 ]
机构
[1] Fukui Gen Hosp, Fukui, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Kanazawa, Japan
[3] Fukui Hlth Sci Univ, Fac Hlth Sci, Dept Rehabil Phys Therapy, Fukui, Japan
[4] Fukui Gen Hosp, Dept Orthopaed Surg, Fukui, Japan
[5] Fukui Gen Hosp, Dept Rehabil Phys Therapy, Fukui, Japan
来源
BONE & JOINT RESEARCH | 2023年 / 12卷 / 05期
关键词
Pose estimation; Reliability; Validity; Knee range of motion; Total knee arthroplasty; GONIOMETRIC MEASUREMENTS; ANALYSIS SYSTEMS; TRACKING; FLEXION; VERIFICATION; KINEMATICS; AGREEMENT;
D O I
10.1302/2046-3758.125.BJR-2022-0257.R1
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Aims We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry. Methods In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland-Altman analyses to evaluate the agreement and error be-tween radiography and the other measurements. Results OpenPose had excellent test-retest reliability (intraclass correlation coefficient (1,1) = 1.000). The R-2 of all regression models indicated large correlations (0.747 to 0.927). In the flexion position, the intraclass correlation coefficients (2,1) of OpenPose indicated excellent agreement (0.953) with radiography. In the extension position, the intraclass correlation coefficients (2,1) indicated good agreement of OpenPose and radiography (0.815) and moderate agreement of goniometry with radiography (0.593). OpenPose had no systematic error in the flexion position, and a 2.3 degrees fixed error in the extension position, compared to radiography. Conclusion OpenPose is a reliable and valid tool for measuring flexion and extension positions after TKA. It has better accuracy than goniometry, especially in the extension position. Accurate measurement values can be obtained with low error, high reproducibility, and no contact, independent of the examiner's skills.
引用
收藏
页码:313 / 320
页数:8
相关论文
共 50 条
  • [1] Recovery of range of knee motion after total knee arthroplasty
    Kubota, M.
    Takedani, H.
    Goto, M.
    [J]. HAEMOPHILIA, 2010, 16 : 120 - 120
  • [2] Accuracy of knee range of motion assessment after total knee arthroplasty
    Lavernia, Carlos
    D'Apuzzo, Michele
    Rossi, Mark D.
    Lee, David
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (06): : 85 - 91
  • [3] Does contralateral knee range of motion predict postoperative knee range of motion after total knee arthroplasty?
    Robert R. Burnham
    Samantha E. Bialek
    Amy Wozniak
    Nicholas M. Brown
    [J]. Knee Surgery & Related Research, 32
  • [4] Does contralateral knee range of motion predict postoperative knee range of motion after total knee arthroplasty?
    Burnham, Robert R., Jr.
    Bialek, Samantha E.
    Wozniak, Amy
    Brown, Nicholas M.
    [J]. KNEE SURGERY & RELATED RESEARCH, 2020, 32 (01)
  • [5] RANGE OF MOTION AFTER TOTAL CONDYLAR KNEE ARTHROPLASTY
    MENKE, W
    SCHMITZ, B
    SALM, S
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1992, 111 (05) : 280 - 281
  • [6] Effect of continuous passive motion on knee flexion range of motion after total knee arthroplasty
    Baloch, Naveed
    Zubairi, Akbar Jaleel
    Rashid, Rizwan Haroon
    Hashmi, Pervaiz Mahmood
    Lakdawala, Riaz Hussain
    [J]. JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2015, 65 (11) : S32 - S34
  • [7] Factors Influencing Range of Motion after Total Knee Arthroplasty
    Farahini, H.
    Moghtadaei, M.
    Bagheri, A.
    Akbarian, E.
    [J]. IRANIAN RED CRESCENT MEDICAL JOURNAL, 2012, 14 (07) : 417 - 421
  • [8] Range of motion after total knee arthroplasty in hemophilic arthropathy
    Kubes, Radovan
    Salaj, Peter
    Hromadka, Rastislav
    Vcelak, Josef
    Kubena, Ales Antonin
    Frydrychova, Monika
    Magersky, Stepan
    Burian, Michal
    Ostadal, Martin
    Vaculik, Jan
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [9] Range of motion after total knee arthroplasty in hemophilic arthropathy
    Radovan Kubeš
    Peter Salaj
    Rastislav Hromádka
    Josef Včelák
    Aleš Antonín Kuběna
    Monika Frydrychová
    Štěpán Magerský
    Michal Burian
    Martin Ošťádal
    Jan Vaculik
    [J]. BMC Musculoskeletal Disorders, 19
  • [10] Knee range of motion after total knee arthroplasty - How important is this as an outcome measure?
    Miner, AL
    Lingard, EA
    Wright, EA
    Sledge, CB
    Katz, JN
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (03): : 286 - 294