Fabrication non-enzymatic electrochemical sensor based on methyl red and graphene oxide nanocomposite modified carbon paste electrode for determination of nitrite in food samples

被引:5
|
作者
Li, Yun [1 ]
Zhang, Xiuli [1 ]
Sun, Yaoqiang [1 ]
Yang, Zhe [2 ]
Liu, Jing [1 ]
机构
[1] Changchun Scitech Univ, Dept Basic Educ & Res, Shuang Yang 130600, Jilin, Peoples R China
[2] Jilin Prov Chuanshi Real Estate Dev Co Ltd, Songyuan 130051, Peoples R China
来源
关键词
Nitrite; Food samples; Non -enzymatic electrochemical sensor; Graphene oxide; Methyl red; Nanocomposite; Amperometry; NITRATE; COMPOSITE; PERFORMANCE; OXIDATION; CHROMATOGRAPHY; ACETAMINOPHEN; NANOPARTICLES; BLUE; ZNO;
D O I
10.1016/j.ijoes.2023.100097
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The purpose of this work was to create a non-enzymatic electrochemical sensor based on methyl red and modified carbon paste electrodes (MR/GO/CPE) that can measure nitrite in food samples. FE-SEM images showed that the assembly of MR on the surface of GO nanosheets caused the combination of GO nanosheets and MR particles to form a MR/GO nanocomposite with a high density of holes and crevasses. Amperometry, CV, and DPV techniques were used to study the electrochemical responses of MR/GO/CPE to the determination of nitrite. The results revealed that the MR/GO/CPE demonstrated sensitive, selective, and stable responses to determination nitrite. According to amplitude studies, the proposed nitrite sensor should have a sensitivity value of 0.12735 mu A/mu M, a large linear range of 0-7000 mu M, and a low detection limit value of 0.011 mu M. In the current study, the accuracy and applicability of the proposed nitrite electrochemical sensor for the determination of nitrite in prepared meat specimens were examined. The results showed good recovery values (more than 96.00 %) and appropriate precision (RSD less than 5.10 %), as well as good agreement between the amperometric measurements and the Test Kit for Nitrate assays. These findings demonstrated that MR/GO/CPE can be used as trustworthy nitrite sensors for tracking nitrite levels in food specimens.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Ultrasensitive electrochemical sensor based on dimethylglyoxime/carbon paste electrode modified with a bimetallic nanocomposite for nickel detection in environmental water samples
    Setiyanto, Henry
    Damayanti, Ajeng Nega Reni
    Sari, Sunarseh Permata
    Saraswaty, Vienna
    Mufti, Nandang
    [J]. INORGANIC CHEMISTRY COMMUNICATIONS, 2024, 169
  • [42] A novel enzymatic glucose biosensor and sensitive non-enzymatic hydrogen peroxide sensor based on graphene and cobalt oxide nanoparticles composite modified glassy carbon electrode
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Veeramani, Vediyappan
    Periakaruppan, Prakash
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 450 - 456
  • [43] A non-enzymatic glucose sensor based on NiO nanoparticles/functionalized SBA 15/MWCNT-modified carbon paste electrode
    Mehdi Baghayeri
    Alireza Sedrpoushan
    Alireza Mohammadi
    Masoud Heidari
    [J]. Ionics, 2017, 23 : 1553 - 1562
  • [44] A non-enzymatic glucose sensor based on NiO nanoparticles/functionalized SBA 15/MWCNT-modified carbon paste electrode
    Baghayeri, Mehdi
    Sedrpoushan, Alireza
    Mohammadi, Alireza
    Heidari, Masoud
    [J]. IONICS, 2017, 23 (06) : 1553 - 1562
  • [45] A Non-Enzymatic Electrochemical Sensor Based on Cerium Oxide Nanocubes for the Rapid Detection of Hydrogen Peroxide Residues in Food Samples
    Shen, Wei
    Shi, Jiaci
    Wang, Xuefeng
    Xu, Pengcheng
    Li, Xinxin
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2024, 19 (09) : 1573 - 1578
  • [46] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Jiang, Bin-Bin
    Wei, Xian-Wen
    Wu, Fang-Hui
    Wu, Kong-Lin
    Chen, Le
    Yuan, Guo-Zan
    Dong, Chao
    Ye, Yin
    [J]. MICROCHIMICA ACTA, 2014, 181 (11-12) : 1463 - 1470
  • [47] A reagentless non-enzymatic hydrogen peroxide sensor presented using electrochemically reduced graphene oxide modified glassy carbon electrode
    Mutyala, Sankararao
    Mathiyarasu, Jayaraman
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 69 : 398 - 406
  • [48] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Bin-Bin Jiang
    Xian-Wen Wei
    Fang-Hui Wu
    Kong-Lin Wu
    Le Chen
    Guo-Zan Yuan
    Chao Dong
    Yin Ye
    [J]. Microchimica Acta, 2014, 181 : 1463 - 1470
  • [49] An electrochemical sensor based on a carbon paste electrode modified with lanthanum nanocomposites for gallic acid determination in fruit juice samples
    Achache, Mohamed
    El-Haddar, Sanae
    El Haddaoui, Hajar
    Idrissi, Ghizlane Elouilali
    Draoui, Khalid
    Bouchta, Dounia
    Choukairi, Mohamed
    [J]. Materials Chemistry and Physics, 2025, 332
  • [50] Electrochemical determination of aripiprazole based on aluminium oxide nanoparticles modified carbon paste electrode
    Ozturk, Funda
    Yuksel, Elif
    Erden, Pinar Esra
    Kilic, Esma
    [J]. TURKISH JOURNAL OF CHEMISTRY, 2023, 47 (01) : 126 - 136