The Efficiency Evaluation of the Reactive Extrusion Process for Polyethylene Terephthalate (PET). Monitoring of the Industrial Foil Manufacturing Process by In-Line Rheological Measurements

被引:5
|
作者
Szymczak, Piotr [1 ,2 ]
Dziadowiec, Damian [1 ,2 ]
Andrzejewski, Jacek [1 ]
Szostak, Marek [1 ]
机构
[1] Poznan Univ Tech, Inst Mat Technol, Fac Mech Engn, Ul Piotrowo 3, PL-61138 Poznan, Poland
[2] EUROCAST Sp Zoo, Wejherowska 9 Str, PL-84220 Strzebielino, Poland
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 06期
关键词
polyethylene terephthalate; foil manufacturing; reactive extrusion; in-line rheology; RECYCLED POLY(ETHYLENE-TEREPHTHALATE); CHAIN EXTENSION; POLYMER MELTS; OFF-LINE; PET; CRYSTALLINITY; COMPOSITES; BEHAVIOR; ONLINE;
D O I
10.3390/app13063434
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application Foil extrusion processing, recycling of waste origin plastics, viscosity monitoring. The main topic of the presented work is the evaluation of the in-line viscometer (VIS) operation installed on the industrial line for polyethylene terephthalate (PET) foil production. The tests were performed during the regular operation of the machine, which results from the need to maintain production continuity. Polymer viscosity control is of particular importance in the production of degradable materials and recycled polymers. The processing of PET film is, therefore, a particularly difficult issue due to the presence of both of these problems at the same time. The conducted research had a two-pronged character: assessment of the correct operation of the viscosity measurement system and testing of the effectiveness of reactive additives during the extrusion process. Measurements were carried out with the use of several types of input materials, including recycled blends. The key tests were carried out with the addition of viscosity modifiers. Measurements conducted during the extrusion process confirmed the effectiveness and high sensitivity of the in-line system (VIS), while clear changes in the polymer flow characteristics were observed only after the addition of chain extenders. The in-line measurements revealed that the addition of 1% of the reactive compound increased the viscosity from the initial 150 Pa center dot s to over 350 Pa center dot s. The most significant increase in viscosity for the additive based on pyromellitic dianhydride (PMDA) confirms the effectiveness of the reactive extrusion method and the suitability of the used measuring. During further analysis, the obtained films were also tested. The results showed no negative effects of the reactive extrusion on the mechanical performance of the foil; however, for recycled materials, the average values of tensile strength and elongation at break have deteriorated. A positive aspect of the use of reactive additives was the greater uniformity of mechanical properties. For some materials, there was a significant increase in the haze factor (transparency), which should be considered a disadvantage.
引用
收藏
页数:13
相关论文
共 42 条
  • [41] A Novel Acetaminophen Soft-Chew Formulation Produced via Hot-Melt Extrusion with In-line Near-Infrared Monitoring as a Process Analytical Technology Tool
    Xu, Pengchong
    Zhang, Jiaxiang
    Bandari, Suresh
    Repka, Michael A.
    AAPS PHARMSCITECH, 2020, 21 (02)
  • [42] Evaluation of in-line particle measurement with an SFT-probe as monitoring tool for process automation using a new time-based buffer approach
    Reimers, Theresa
    Thies, Jochen
    Dietrich, Stefan
    Quodbach, Julian
    Pein-Hackelbusch, Miriam
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 128 : 162 - 170