Characterizing a nitrogen microwave inductively coupled atmospheric-pressure plasma ion source for element mass spectrometry

被引:5
|
作者
Kuonen, Monique [1 ]
Niu, Guanghui [1 ]
Hattendorf, Bodo [1 ]
Gunther, Detlef [1 ]
机构
[1] Swiss Fed Inst Technol, Dept Chem & Appl Biosci, Lab Inorgan Chem, Vladimir Prelog Weg 1, CH-8093 Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
DYNAMIC REACTION CELL; ICP-MS; LASER-ABLATION; COLLISION; AEROSOLS; DESIGN; ARGON;
D O I
10.1039/d2ja00369d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-power nitrogen-based microwave inductively coupled atmospheric-pressure plasma was coupled to a quadrupole mass spectrometer to investigate its characteristics as an ion source for element mass spectrometry. The influence of operating conditions on analyte sensitivity, plasma background, and polyatomic ion formation was investigated for conventional solution-based analysis. By varying the forward power and the nebulizer gas flow rate, the plasma background ions were found to decrease with increasing gas flow rates and decreasing operating power. Analyte ions showed different trends, which could be related to the physical-chemical properties of the elements. We could identify three groups based on the location of maximum intensity in the power vs. flow rate contour plot. Atomic ions of elements with low first ionization energy and low oxygen bond strength were found to maximize at a high nebulizer gas flow rate and lower microwave power. Elements with intermediate ionization energy and higher oxygen bond strength required higher power settings for optimum sensitivity, while elements with the highest ionization energies required the highest power and lowest gas flow rates for their optimization. The latter group showed a substantial suppression in sensitivity compared to elements of similar mass, which is considered to result from the high abundance of NO in the plasma source, whose ionization energy is close to that of these elements. Metal oxide ions were found at similar or higher abundances than in the conventional argon-based ICP and could be minimized only by using a low gas flow rate and high power settings. These general trends were also observed when the vacuum interface was modified. To change the dynamics of the supersonic expansion, different sampler cone orifice sizes and sampler-skimmer distances were investigated and the interface pressure was lowered through an additional pump. These modifications did not yield significant differences in ion transmission but lowering the interface pressure reduced the relative abundance of metal oxide ions. The limits of detection were evaluated for optimized plasma conditions and found comparable to those of an argon ICP source with the same mass spectrometer.
引用
收藏
页码:758 / 765
页数:8
相关论文
共 50 条
  • [1] Replacing the Argon ICP: Nitrogen Microwave Inductively Coupled Atmospheric-Pressure Plasma (MICAP) for Mass Spectrometry
    Schild, Matthias
    Gundlach-Graham, Alexander
    Menon, Ashok
    Jevtic, Jovan
    Pikelja, Velibor
    Tanner, Martin
    Hattendorf, Bodo
    Gunther, Detlef
    ANALYTICAL CHEMISTRY, 2018, 90 (22) : 13443 - 13450
  • [2] Multielement analysis in soils using nitrogen microwave inductively coupled atmospheric-pressure plasma mass spectrometry
    You, Zengchao
    Akkus, Asli
    Weisheit, Wolfram
    Giray, Thorsten
    Penk, Sibylle
    Buttler, Sabine
    Recknagel, Sebastian
    Abad, Carlos
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (12) : 2556 - 2562
  • [3] Investigation of matrix effects in nitrogen microwave inductively coupled atmospheric-pressure plasma mass spectrometry (MICAP-MS) for trace element analysis in steels
    Winckelmann, Alexander
    Roik, Janina
    Recknagel, Sebastian
    Abad, Carlos
    You, Zengchao
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (06) : 1253 - 1260
  • [4] New inductively coupled plasma for atomic spectrometry: the microwave-sustained, inductively coupled, atmospheric-pressure plasma (MICAP)
    Schwartz, Andrew J.
    Cheung, Yan
    Jevtic, Jovan
    Pikelja, Velibor
    Menon, Ashok
    Ray, Steven J.
    Hieftje, Gary M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (02) : 440 - 449
  • [5] Atmospheric-pressure helium inductively coupled plasmas for elemental mass spectrometry
    Zhang, H
    Nam, SH
    Cai, MX
    Montaser, A
    APPLIED SPECTROSCOPY, 1996, 50 (04) : 427 - 435
  • [6] USE OF THE MICROWAVE-INDUCED NITROGEN DISCHARGE AT ATMOSPHERIC-PRESSURE AS AN ION-SOURCE FOR ELEMENTAL MASS-SPECTROMETRY
    WILSON, DA
    VICKERS, GH
    HIEFTJE, GM
    ANALYTICAL CHEMISTRY, 1987, 59 (13) : 1664 - 1670
  • [7] Atmospheric- and low-pressure inductively coupled plasma as an ion source for a mass spectrometer
    Kartasheva, MA
    Maleshin, MN
    Gerasimov, GN
    Danilenkov, VI
    JOURNAL OF OPTICAL TECHNOLOGY, 2003, 70 (01) : 51 - 54
  • [8] New coil geometries for the study of secondary discharge in atmospheric-pressure helium inductively coupled plasma mass spectrometry
    Jorabchi, K
    Montaser, A
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (09) : 1471 - 1479
  • [9] Ion chromatography - nitrogen-sustained microwave inductively coupled atmospheric pressure plasma - mass spectrometry (IC-MICAP-MS) for arsenic speciation analysis in rice
    Mukta, Shahnaz
    Gundlach-Graham, Alexander
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (02) : 491 - 499
  • [10] Inductively coupled plasma mass spectrometry with ambient helium surrounding ion source
    Jin, Xianzhong
    Li, Lingfeng
    Hang, Wei
    Chen, Jianguo
    Huang, Benli
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (12) : 1052 - 1055