Ion chromatography - nitrogen-sustained microwave inductively coupled atmospheric pressure plasma - mass spectrometry (IC-MICAP-MS) for arsenic speciation analysis in rice

被引:2
|
作者
Mukta, Shahnaz [1 ]
Gundlach-Graham, Alexander [1 ]
机构
[1] Iowa State Univ, Dept Chem, Ames, IA 50011 USA
关键词
POLYATOMIC INTERFERENCES; ATOMIC-EMISSION; SAMPLES; MATRIX; ACCUMULATION; EXTRACTION; EXPOSURE; ARGON; WHEAT;
D O I
10.1039/d3ja00400g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of a nitrogen (N2)-sustained Microwave Inductively Coupled Atmospheric-Pressure Plasma (MICAP) - Quadrupole Mass Spectrometer (QMS) was explored as an alternative to the traditional argon (Ar) equivalent for arsenic (As) analysis in rice. Conventional Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) can be limited by Ar-based spectral interferences depending on sample matrices. Specifically, for the analysis of As, argon chloride ions (40Ar35Cl+) can interfere with the detection of the monoisotopic 75As+, and this interference can lead to systematic errors in As quantification. With N2-sustained MICAP-QMS, major plasma background species are N2-based, which eliminates the spectral interference possibility at mass-to-charge (m/z) 75 from 40Ar35Cl+. In this work, we present the first combination of the N2-MICAP-MS with anion exchange chromatography for As speciation and quantification from several rice varieties. We used a slightly modified As-species extraction procedure per Food and Drug Administration (FDA) protocol EAM 4.11. In all rice samples, we quantified the As amount in the species arsenite (As(iii)), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA), and arsenate (As(v)), with detection limits of 0.26, 0.26, 0.13 and 0.22 mu g kg-1, respectively. We validated our experimental method with Standard Reference Material (SRM) NIST 1568b rice flour and obtained 85-110% recoveries for quantification of As from species. Speciation results were comparable to total As concentration determined by MICAP-MS. The use of N2-MICAP-MS would allow for quantification of As in chloride containing matrices; here, we demonstrate strong matrix tolerance of the MICAP-MS for solutions with up to 1% (w/w) sodium chloride. These results suggest that the MICAP-MS is a promising approach for the analysis of As species in more complex matrices. Ion chromotagraphy is coupled to a nitrogen-sustained Microwave Inductively Coupled Atmospheric-Pressure Plasma Mass Spectrometer (MICAP-MS) for arsenic speciation analysis in rice.
引用
收藏
页码:491 / 499
页数:9
相关论文
共 50 条
  • [1] New inductively coupled plasma for atomic spectrometry: the microwave-sustained, inductively coupled, atmospheric-pressure plasma (MICAP)
    Schwartz, Andrew J.
    Cheung, Yan
    Jevtic, Jovan
    Pikelja, Velibor
    Menon, Ashok
    Ray, Steven J.
    Hieftje, Gary M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (02) : 440 - 449
  • [2] Replacing the Argon ICP: Nitrogen Microwave Inductively Coupled Atmospheric-Pressure Plasma (MICAP) for Mass Spectrometry
    Schild, Matthias
    Gundlach-Graham, Alexander
    Menon, Ashok
    Jevtic, Jovan
    Pikelja, Velibor
    Tanner, Martin
    Hattendorf, Bodo
    Gunther, Detlef
    ANALYTICAL CHEMISTRY, 2018, 90 (22) : 13443 - 13450
  • [3] Speciation of Arsenic in Rice by Ion Chromatography with Online Anion Suppression and Inductively Coupled Plasma Mass Spectrometry
    Cui, He
    Zhu, Qianlin
    Dong, Lizhen
    Shan, Baotian
    Han, Tingting
    Li, Huixin
    Cai, Feng
    ANALYTICAL LETTERS, 2017, 50 (06) : 1040 - 1048
  • [4] Investigation of matrix effects in nitrogen microwave inductively coupled atmospheric-pressure plasma mass spectrometry (MICAP-MS) for trace element analysis in steels
    Winckelmann, Alexander
    Roik, Janina
    Recknagel, Sebastian
    Abad, Carlos
    You, Zengchao
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (06) : 1253 - 1260
  • [5] Speciation of arsenic by ion chromatography inductively coupled plasma mass spectrometry using ammonium eluents
    Chen, ZuLiang
    Akter, Kazi Farzana
    Mahmudur, Mohammad
    Rahman
    Naidu, Ravendra
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (17) : 2671 - 2676
  • [6] Arsenic speciation analysis of human urine using ion exchange chromatography coupled to inductively coupled plasma mass spectrometry
    Xie, Ruimin
    Johnson, Willie
    Spayd, Steve
    Hall, Gene S.
    Buckley, Brian
    ANALYTICA CHIMICA ACTA, 2006, 578 (02) : 186 - 194
  • [7] Determination of calcium, iron, and selenium in human serum by isotope dilution analysis using nitrogen microwave inductively coupled atmospheric pressure plasma mass spectrometry (MICAP-MS)
    You, Zengchao
    Winckelmann, Alexander
    Vogl, Jochen
    Recknagel, Sebastian
    Abad, Carlos
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (13) : 3117 - 3125
  • [8] Speciation analysis of arsenic compounds in edible oil by ion chromatography-inductively coupled plasma mass spectrometry
    Chu, Yun-Ling
    Jiang, Shiuh-Jen
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (31) : 5175 - 5179
  • [9] Determination of total and speciated arsenic in rice by ion chromatography and inductively coupled plasma mass spectrometry
    Heitkemper, DT
    Vela, NP
    Stewart, KR
    Westphal, CS
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (04) : 299 - 306
  • [10] Characterizing a nitrogen microwave inductively coupled atmospheric-pressure plasma ion source for element mass spectrometry
    Kuonen, Monique
    Niu, Guanghui
    Hattendorf, Bodo
    Gunther, Detlef
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (03) : 758 - 765