Diagnostic reference level quantities for adult chest and abdomen-pelvis CT examinations: correlation with organ doses

被引:2
|
作者
Costa, Paulo Roberto [1 ]
Tomal, Alessandra [2 ]
de Oliveira Castro, Jullianna Cristina [3 ]
Nunes, Isabella Paziam Fernandes [3 ]
Nersissian, Denise Yanikian [1 ]
Sawamura, Marcio Valente Yamada [4 ]
Leao Filho, Hilton [4 ]
Lee, Choonsik [5 ]
机构
[1] Univ Sao Paulo, Inst Phys, R Matao 1371, BR-05508090 Sao Paulo, SP, Brazil
[2] Univ Estadual Campinas, Inst Phys Gleb Watagin, Campinas, Brazil
[3] Univ Sao Paulo, Med Sch, Sao Paulo, Brazil
[4] Univ Sao Paulo, Med Sch, Div Radiol, Sao Paulo, Brazil
[5] NCI, Div Canc Epidemiol & Genet, NIH, Bethesda, MD USA
基金
瑞典研究理事会; 巴西圣保罗研究基金会;
关键词
Organ doses; Computed tomography; Chest; Abdomen-pelvis; Statistics; SIZE; PHANTOMS; FAMILY; SSDE;
D O I
10.1186/s13244-023-01403-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesTo evaluate correlations between DRL quantities (DRLq) stratified into patient size groups for non-contrast chest and abdomen-pelvis CT examinations in adult patients and the corresponding organ doses.MethodsThis study presents correlations between DRLq (CTDIvol, DLP and SSDE) stratified into patient size ranges and corresponding organ doses shared in four groups: inside, peripheral, distributed and outside. The demographic, technical and dosimetric parameters were used to identify the influence of these quantities in organ doses. A robust statistical method was implemented in order to establish these correlations and its statistical significance.ResultsMedian values of the grouped organ doses are presented according to the effective diameter ranges. Organ doses in the regions inside the imaged area are higher than the organ doses in peripheral, distributed and outside regions, excepted to the peripheral doses associated with chest examinations. Different levels of statistical significance between organ doses and the DRLq were presented.ConclusionsCorrelations between DRLq and target-organ doses associated with clinical practice can support guidance's to the establishment of optimization criteria. SSDE demonstrated to be significant in the evaluation of organ doses is also highlighted. The proposed model allows the design of optimization actions with specific risk-reduction results.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] PATIENT-SPECIFIC ORGAN DOSE EVALUATION BASED ON MONTE CARLO SIMULATION AND DOSE METRICS IN PAEDIATRIC CHEST-ABDOMEN-PELVIS CT EXAMINATIONS
    Fujii, Keisuke
    Nomura, Keiichi
    Muramatsu, Yoshihisa
    Ota, Hiroyuki
    [J]. RADIATION PROTECTION DOSIMETRY, 2021, 197 (01) : 46 - 53
  • [22] PATIENT DOSES IN CT EXAMINATIONS IN SWITZERLAND: IMPLEMENTATION OF NATIONAL DIAGNOSTIC REFERENCE LEVELS
    Treier, R.
    Aroua, A.
    Verdun, F. R.
    Samara, E.
    Stuessi, A.
    Trueb, Ph. R.
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 142 (2-4) : 244 - 254
  • [23] NATIONAL DIAGNOSTIC REFERENCE LEVELS AND ACHIEVABLE DOSES FOR STANDARD CT EXAMINATIONS IN SUDAN
    Suliman, I. I.
    Bashier, Einas H.
    Awad, Mustafa
    Ahmed, Ibrahim
    Mohamed, Suhair
    Ahmed, Nada A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2021, 196 (1-2) : 1 - 9
  • [24] Study to Establish Diagnostic Reference Levels of Adults CT Chest Examinations in Algeria
    Meddad, F.
    Merad, A.
    Guedioura, D.
    Khelassi-Toutaoui, N.
    [J]. 1ST INTERNATIONAL CONFERENCE ON RADIATIONS AND APPLICATIONS (ICRA-2017), 2018, 1994
  • [25] Organ Dose in Abdomen-Pelvis CT: Does TG 111 Equilibrium Dose Concept Better Accounts for KVp Dependence Than Conventional CTDI?
    Li, X.
    Morgan, A.
    Dong, F.
    Primak, A.
    Davros, W.
    Segars, W.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 425 - 425
  • [26] The Ability of CTDIvol to Estimate Organ Doses from Typical Tube Current Modulated Abdomen/Pelvis CT Scans
    Khatonabadi, M.
    Turner, A.
    Zhang, D.
    DeMarco, J.
    Cagnon, C.
    McNitt-Gray, M.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [27] Estimation of adult patient doses for Chest X-ray diagnostic examinations in a Tertiary Institution
    Okungbowa, E. G.
    Eze, S. E.
    Adams, H. O.
    [J]. EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2017, 46 : S400 - S400
  • [28] Computed normalised effective doses to an Indian adult in conventional diagnostic X ray chest examinations
    Biju, K
    Nagarajan, PS
    [J]. RADIATION PROTECTION DOSIMETRY, 2000, 88 (02) : 119 - 127
  • [29] ADULT CT EXAMINATIONS IN ALGERIA: TOWARDS UPDATING NATIONAL DIAGNOSTIC REFERENCE LEVELS
    Khelassi-Toutaoui, Nadia
    Merad, Ahmed
    Tsapaki, Virginia
    Meddad, Fouzia
    Sakhri-Brahimi, Zakia
    Guedioura, Diana
    Saadi, Samia
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 190 (04) : 364 - 371
  • [30] Abdomen and pelvis computed tomography procedure: Effective dose assessment and establishment of a local diagnostic reference level
    Almujally, Abdullah
    Alenezi, Saad
    Aldosary, Khalid Nasser
    Otayni, Ahmed
    Sulieman, Abdelmoneim
    Abdelghani, Amr
    Tamam, Nissren
    Mohtasib, Rafat
    Masawi, Ahmed
    Moftah, Belal
    Bradley, D. A.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 203