Feasibility of Multi-Zone Simulation for Estimating Contributions of Outdoor Particulate Pollution to Indoor Particulate Matter Concentration

被引:0
|
作者
Lee, Byung-Hee [1 ]
Baek, Seung-Hyo [2 ]
机构
[1] Land & Housing Inst, Daejeon 34047, South Korea
[2] Mokwon Univ, Div Architecture, Daejeon 35349, South Korea
基金
新加坡国家研究基金会;
关键词
particulate matter; airflow; multi-zone simulation; indoor; outdoor concentration (I; O) ratio; INDOOR/OUTDOOR RELATIONSHIPS; DEPOSITION RATE; AIR CLEANERS; PARTICLE; SIZE; BUILDINGS; SMOKE; TRANSPORT; EXPOSURE; IMPACT;
D O I
10.3390/buildings13030673
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As concerns about the health effects of particulate matter (PM) are growing, controlling indoor PM has become vital for ensuring occupants' health. Active strategies, such as air purification and high-performance filtering, are widely implemented to control indoor PM. However, passive strategies, including air-tightness and compartmentalization, are promising alternatives, as demonstrated by recent studies. To enhance the implementation of passive strategies, an appropriate evaluation method for passive designs must be established. The objective of this study was to investigate whether a multi-zone-based method is suitable for the evaluation of passive strategies. Multi-zone simulations were performed for four seasons, and indoor/outdoor concentration (I/O) ratios were obtained for the exterior, interior, and corridor on every floor of the reference building. The I/O ratios at different locations indicated that the outdoor particle transport in the building was accurately estimated according to the airflow rate and path. Moreover, in addition to the effects of changes in the outdoor temperature on PM transport through the building envelope, the particle size is a significant factor affecting indoor PM concentrations. The results of this study indicated that the multi-zone method can effectively estimate the number of outdoor particles that penetrate the building envelope in different seasons and the indoor particle concentration at different indoor locations.
引用
收藏
页数:20
相关论文
共 50 条
  • [11] A Study on Indoor/Outdoor Concentration of Particulate Matter in Rural Residential Houses in India
    Massey, David. D.
    Kulshrestha, Aditi
    Taneja, Ajay
    [J]. PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON ENVIRONMENTAL AND COMPUTER SCIENCE, 2009, : 218 - +
  • [12] A PILOT INDOOR-OUTDOOR STUDY OF ORGANIC PARTICULATE MATTER AND PARTICULATE MUTAGENICITY
    LIOY, PJ
    AVDENKO, M
    HARKOV, R
    ATHERHOLT, T
    DAISEY, JM
    [J]. JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1985, 35 (06): : 653 - 657
  • [13] Estimating the mortality attributable to indoor exposure to particulate matter of outdoor origin in mainland China
    Chen, Lili
    Wang, Hao
    Wang, Ziwei
    Dong, Zhaomin
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 872
  • [14] Particulate matter in the indoor and outdoor air of a gymnasium and a fronton
    Alves, Celia
    Calvo, Ana I.
    Marques, Liliana
    Castro, Amaya
    Nunes, Teresa
    Coz, Esther
    Fraile, Roberto
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2014, 21 (21) : 12390 - 12402
  • [15] COMPARISON OF SUSPENDED PARTICULATE MATTER OF INDOOR AND OUTDOOR AIR
    JACOBS, MB
    GOLDWATER, LJ
    FERGANY, A
    [J]. INTERNATIONAL JOURNAL OF AIR AND WATER POLLUTION, 1962, 6 (04): : 377 - 380
  • [16] Inflammatory health effects of indoor and outdoor particulate matter
    Wu, Weidong
    Jin, Yuefei
    Carlsten, Chris
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2018, 141 (03) : 833 - 844
  • [17] STUDY ON THE TRANSFER LAW OF OUTDOOR AND INDOOR PARTICULATE MATTER
    Zhang, Dianguang
    Gao, Xing
    Wu, Huaxin
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 253 - 257
  • [18] Particulate matter in the indoor and outdoor air of a gymnasium and a fronton
    Célia Alves
    Ana I. Calvo
    Liliana Marques
    Amaya Castro
    Teresa Nunes
    Esther Coz
    Roberto Fraile
    [J]. Environmental Science and Pollution Research, 2014, 21 : 12390 - 12402
  • [19] Indoor and Outdoor Particulate Matter Variability in Athens, Greece
    Nastos, P. T.
    Larissi, I. K.
    Grigoropoulos, K. N.
    Antoniou, A.
    Paliatsos, A. G.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2013, 22 (03) : 586 - 592
  • [20] Characteristics of the Concentration Change of the Particulate Matter in the Indoor and Outdoor Existing Public Office Buildings
    Yu, Liang
    Jia, Ji
    Chen, Shuang
    Lu, Qi
    Feng, Guohui
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3367 - 3372