Coated poly-4-hydroxybutyrate (Phasix ST™) mesh is safe and effective for hiatal hernia repair: our institutional experience and review of the literature

被引:1
|
作者
Fair, Lucas [1 ,2 ,4 ]
Ward, Marc [1 ,2 ,3 ]
Adhikari, Preston [3 ]
Tran, Daniel [3 ]
Pina, Emerald [4 ]
Ramakrishnan, Sudha [5 ]
Ogola, Gerald [4 ]
Aladegbami, Bola [1 ,2 ,3 ]
Leeds, Steven [2 ,3 ,6 ]
机构
[1] Baylor Univ, Med Ctr, Dept Minimally Invas Surg, Dallas, TX 75246 USA
[2] Baylor Scott & White Hlth, Ctr Adv Surg, Dallas, TX 75246 USA
[3] Texas A&M Coll Med, Bryan, TX 77807 USA
[4] Res Inst, Baylor Scott & White Hlth, Dallas, TX USA
[5] Baylor Scott & White Hlth, Baylor Hlth Sci Lib, Dallas, TX USA
[6] Baylor Univ, Med Ctr, Dept Minimally Invas Surg, 3417 Gaston Ave,Suite 965, Dallas, TX 75246 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2024年 / 38卷 / 02期
关键词
Hiatal hernia; Bioabsorable mesh; Recurrence; Phasix; Poly-4-hydroxybutyrate; BIOLOGIC PROSTHESIS; MULTICENTER; RECURRENCE;
D O I
10.1007/s00464-023-10604-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundPoly-4-hydroxybutyrate (P4HB) is a bioabsorbable mesh with a non-adhesive coating on one side that is being used to reinforce the hiatus during hiatal hernia repair; however, there is limited data regarding its use. The aim of this study was to investigate outcomes after hiatal hernia repair using this mesh at our institution and through a review of the literature.MethodsAn institutional review board-approved prospective database was retrospectively reviewed for all patients undergoing hiatal hernia repair from April 2018 to December 2022. A systematic review with meta-analysis was conducted to evaluate outcomes using P4HB coated mesh.ResultsIn our institutional cohort, there were 230 patients (59 males; 171 females) with a mean follow-up of 20 +/- 14.6 months. No mesh-related complications occurred. Hernia recurrence was diagnosed in 11 patients (4.8%) with a median time to recurrence of 16 months. In the systematic review, 4 studies with 221 patients (76 males; 145 females) were included. Median follow-up ranged from 12 to 27 months. Recurrence rate in these studies was reported from 0 to 8.8%, with a total of 12 recurrences identified. Like our institutional cohort, no mesh-related complications were reported. After our recurrences were combined with those from the systematic review, a total of 23 recurrences were included in the meta-analysis. Our meta-analysis revealed a low recurrence rate following hiatal hernia repair with P4HB coated mesh (incidence rate per 100 person-years, 2.82; 95% confidence interval, 1.60, 4.04).ConclusionP4HB coated mesh is safe and effective for hiatal hernia repairs.
引用
收藏
页码:830 / 836
页数:7
相关论文
共 38 条
  • [21] Long-Term, Prospective, Multicenter Study of Poly-4-Hydroxybutyrate Mesh (Phasix Mesh) for Hernia Repair in Cohort at Risk for Complication: 60-Month Follow-Up
    Roth, John Scott
    Anthone, Gary J.
    Selzer, Don J.
    Poulose, Benjamin K.
    Pierce, Richard A.
    Bittner, James G.
    Hope, William W.
    Dunn, Raymond M.
    Martindale, Robert G.
    Goldblatt, Matthew, I
    Earle, David B.
    Romanelli, John R.
    Mancini, Gregory J.
    Greenberg, Jacob A.
    Linn, John G.
    Parra-Davila, Eduardo
    Sandler, Bryan J.
    Deeken, Corey R.
    Badhwar, Amit
    Salluzzo, Jennifer L.
    Voeller, Guy R.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2022, 235 (06) : 894 - 904
  • [22] P-030 LAPAROSCOPIC VENTRAL HERNIA REPAIR WITH POLY-4-HYDROXYBUTYRATE ABSORBABLE BARRIER COMPOSITE MESH
    Alshammari, S.
    Aldohayan, A.
    BRITISH JOURNAL OF SURGERY, 2022, 109
  • [23] Minimizing the Mesh Footprint: 5-year Follow Up After Hernia Repair Using Poly-4-hydroxybutyrate Mesh
    Talwar, Ankoor
    Perry, Nikhita J.
    Desai, Abhishek
    McAuliffe, Phoebe
    Thrippleton, Sheri L.
    Broach, Robyn B.
    Fischer, John Patrick
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2023, 236 (05) : S41 - S42
  • [24] Shifting the Goalpost in Ventral Hernia Care: 5-year Outcomes after Ventral Hernia Repair with Poly-4-hydroxybutyrate Mesh
    Talwar, Ankoor A.
    Perry, Nikhita J.
    McAuliffe, Phoebe B.
    Desai, Abhishek A.
    Thrippleton, Sheri
    Broach, Robyn B.
    Fischer, John P.
    HERNIA, 2022, 26 (06) : 1635 - 1643
  • [25] Shifting the Goalpost in Ventral Hernia Care: 5-year Outcomes after Ventral Hernia Repair with Poly-4-hydroxybutyrate Mesh
    Ankoor A. Talwar
    Nikhita J. Perry
    Phoebe B. McAuliffe
    Abhishek A. Desai
    Sheri Thrippleton
    Robyn B. Broach
    John P. Fischer
    Hernia, 2022, 26 : 1635 - 1643
  • [26] Evaluation of a fully absorbable poly-4-hydroxybutyrate/absorbable barrier composite mesh in a porcine model of ventral hernia repair
    Jeffrey R. Scott
    Corey R. Deeken
    Robert G. Martindale
    Michael J. Rosen
    Surgical Endoscopy, 2016, 30 : 3691 - 3701
  • [27] P-015 POLY-4-HYDROXYBUTYRATE ABSORBABLE BARRIER COMPOSITE MESH AND POLY-PROLINE MESH: DUAL REPAIR FOR HUGE INCISIONAL HERNIA
    Binjaloud, A.
    Alshammari, S.
    Aldohayan, A.
    BRITISH JOURNAL OF SURGERY, 2022, 109
  • [28] Evaluation of a fully absorbable poly-4-hydroxybutyrate/absorbable barrier composite mesh in a porcine model of ventral hernia repair
    Scott, Jeffrey R.
    Deeken, Corey R.
    Martindale, Robert G.
    Rosen, Michael J.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2016, 30 (09): : 3691 - 3701
  • [29] Ventral hernia repair using bioresorbable poly-4-hydroxybutyrate mesh in clean and contaminated surgical fields: a systematic review and meta-analysis
    Ahmed, A.
    Gandhi, S.
    Ganam, S.
    Diab, A. -R F.
    Mhaskar, R.
    Sujka, J.
    Ducoin, C.
    Docimo Jr, S.
    HERNIA, 2024, 28 (02) : 575 - 584
  • [30] Ventral hernia repair using bioresorbable poly-4-hydroxybutyrate mesh in clean and contaminated surgical fields: a systematic review and meta-analysis
    A. Ahmed
    S. Gandhi
    S. Ganam
    A.-R. F. Diab
    R. Mhaskar
    J. Sujka
    C. DuCoin
    S. Docimo
    Hernia, 2024, 28 : 575 - 584