Coated poly-4-hydroxybutyrate (Phasix ST™) mesh is safe and effective for hiatal hernia repair: our institutional experience and review of the literature

被引:1
|
作者
Fair, Lucas [1 ,2 ,4 ]
Ward, Marc [1 ,2 ,3 ]
Adhikari, Preston [3 ]
Tran, Daniel [3 ]
Pina, Emerald [4 ]
Ramakrishnan, Sudha [5 ]
Ogola, Gerald [4 ]
Aladegbami, Bola [1 ,2 ,3 ]
Leeds, Steven [2 ,3 ,6 ]
机构
[1] Baylor Univ, Med Ctr, Dept Minimally Invas Surg, Dallas, TX 75246 USA
[2] Baylor Scott & White Hlth, Ctr Adv Surg, Dallas, TX 75246 USA
[3] Texas A&M Coll Med, Bryan, TX 77807 USA
[4] Res Inst, Baylor Scott & White Hlth, Dallas, TX USA
[5] Baylor Scott & White Hlth, Baylor Hlth Sci Lib, Dallas, TX USA
[6] Baylor Univ, Med Ctr, Dept Minimally Invas Surg, 3417 Gaston Ave,Suite 965, Dallas, TX 75246 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2024年 / 38卷 / 02期
关键词
Hiatal hernia; Bioabsorable mesh; Recurrence; Phasix; Poly-4-hydroxybutyrate; BIOLOGIC PROSTHESIS; MULTICENTER; RECURRENCE;
D O I
10.1007/s00464-023-10604-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundPoly-4-hydroxybutyrate (P4HB) is a bioabsorbable mesh with a non-adhesive coating on one side that is being used to reinforce the hiatus during hiatal hernia repair; however, there is limited data regarding its use. The aim of this study was to investigate outcomes after hiatal hernia repair using this mesh at our institution and through a review of the literature.MethodsAn institutional review board-approved prospective database was retrospectively reviewed for all patients undergoing hiatal hernia repair from April 2018 to December 2022. A systematic review with meta-analysis was conducted to evaluate outcomes using P4HB coated mesh.ResultsIn our institutional cohort, there were 230 patients (59 males; 171 females) with a mean follow-up of 20 +/- 14.6 months. No mesh-related complications occurred. Hernia recurrence was diagnosed in 11 patients (4.8%) with a median time to recurrence of 16 months. In the systematic review, 4 studies with 221 patients (76 males; 145 females) were included. Median follow-up ranged from 12 to 27 months. Recurrence rate in these studies was reported from 0 to 8.8%, with a total of 12 recurrences identified. Like our institutional cohort, no mesh-related complications were reported. After our recurrences were combined with those from the systematic review, a total of 23 recurrences were included in the meta-analysis. Our meta-analysis revealed a low recurrence rate following hiatal hernia repair with P4HB coated mesh (incidence rate per 100 person-years, 2.82; 95% confidence interval, 1.60, 4.04).ConclusionP4HB coated mesh is safe and effective for hiatal hernia repairs.
引用
收藏
页码:830 / 836
页数:7
相关论文
共 38 条
  • [1] Coated poly-4-hydroxybutyrate (Phasix ST™) mesh is safe and effective for hiatal hernia repair: our institutional experience and review of the literature
    Lucas Fair
    Marc Ward
    Preston Adhikari
    Daniel Tran
    Emerald Pina
    Sudha Ramakrishnan
    Gerald Ogola
    Bola Aladegbami
    Steven Leeds
    Surgical Endoscopy, 2024, 38 : 830 - 836
  • [2] Ventral hernia repair with poly-4-hydroxybutyrate mesh
    Margaret A. Plymale
    Daniel L. Davenport
    Adam Dugan
    Amanda Zachem
    John Scott Roth
    Surgical Endoscopy, 2018, 32 : 1689 - 1694
  • [3] Poly-4-hydroxybutyrate (Phasix™) mesh onlay in complex abdominal wall repair
    Levy, Adam S.
    Bernstein, Jaime L.
    Premaratne, Ishani D.
    Rohde, Christine H.
    Otterburn, David M.
    Morrison, Kerry A.
    Lieberman, Michael
    Pomp, Alfons
    Spector, Jason A.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2021, 35 (05): : 2049 - 2058
  • [4] Poly-4-hydroxybutyrate (Phasix™) mesh onlay in complex abdominal wall repair
    Adam S. Levy
    Jaime L. Bernstein
    Ishani D. Premaratne
    Christine H. Rohde
    David M. Otterburn
    Kerry A. Morrison
    Michael Lieberman
    Alfons Pomp
    Jason A. Spector
    Surgical Endoscopy, 2021, 35 : 2049 - 2058
  • [5] Ventral hernia repair with poly-4-hydroxybutyrate mesh
    Plymale, Margaret A.
    Davenport, Daniel L.
    Dugan, Adam
    Zachem, Amanda
    Roth, John Scott
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2018, 32 (04): : 1689 - 1694
  • [6] Characterization of poly-4-hydroxybutyrate mesh for hernia repair applications
    Martin, David P.
    Badhwar, Amit
    Shah, Devang V.
    Rizk, Said
    Eldridge, Stephen N.
    Gagne, Darcy H.
    Ganatra, Amit
    Darois, Roger E.
    Williams, Simon F.
    Tai, Hsin-Chien
    Scott, Jeffrey R.
    JOURNAL OF SURGICAL RESEARCH, 2013, 184 (02) : 766 - 773
  • [7] POLY-4-HYDROXYBUTYRATE MESH (PHASIX MESH) FOR VENTRAL HERNIA REPAIRS: A SINGLE SURGEON RETROSPECTIVE SERIES
    Klifto, Kevin
    Othman, Sammy
    Weiss, Eric
    Kovach, Stephen
    BRITISH JOURNAL OF SURGERY, 2021, 108
  • [8] The use of poly-4-hydroxybutyrate (P4HB, Phasix™) mesh in ventral hernia repair: a systematic review and meta-analysis
    Tran, Daniel H.
    Rubarth, Charles
    Leeds, Steven G.
    Fair, Luke
    Mcgowan, Titus
    Ramakrishnan, Sudha
    Shabbir, Rehma
    Ogola, Gerald
    Ward, Marc A.
    Aladegbami, Bola
    HERNIA, 2024, 28 (04) : 989 - 1004
  • [9] Histological study of biosynthetic poly-4-hydroxybutyrate prostheses (Phasix™) in a human and literature review
    Catalan Garza, Vanesa
    Pena Soria, Maria Jesus
    Saez Carlin, Patricia
    Garcia Diego, Guillermo
    Cabeza Gomez, Juan Jesus
    Anula Fernandez, Rocio
    Torres Garcia, Antonio Jose
    REVISTA HISPANOAMERICANA DE HERNIA, 2019, 7 (02) : 66 - 71
  • [10] Outcomes of Poly-4-hydroxybutyrate Mesh in Ventral Hernia Repair: A Systematic Review and Pooled Analysis
    Mellia, Joseph A.
    Othman, Sammy
    Naga, Hani, I
    Messa, Charles A.
    Elfanagely, Omar
    Byrnes, Yasmeen M.
    Basta, Marten N.
    Fischer, John P.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2020, 8 (12) : E3158