Effects of design parameters and operating conditions on the economic and environmental analysis for PEMWE hydrogen refueling station

被引:9
|
作者
Hassan, Alamir H. [1 ,2 ]
Liao, Zhirong [1 ]
Wang, Kaichen [1 ]
Xu, Chao [1 ]
Abdelsamie, Mostafa M. [2 ]
机构
[1] North China Elect Power Univ, Sch Energy Power & Mech Engn, Key Lab Power Stn Energy Transfer Convers & Syst M, Beijing 102206, Peoples R China
[2] Helwan Univ, Fac Engn Mattaria, Mech Power Engn Dept, Cairo 11718, Egypt
基金
中国国家自然科学基金;
关键词
Proton exchange membrane; Hydrogen refueling station; Profitability analysis; Net present value; Environmental analysis; POWER-TO-GAS; LIFE-CYCLE ASSESSMENT; NET PRESENT VALUE; WATER ELECTROLYSIS; ENERGY; CO2; STORAGE; COST;
D O I
10.1016/j.jclepro.2023.139607
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hydrogen is a prominent clean fuel option for combatting global warming and producing low-emission, ecologically friendly electricity. Consequently, the proton exchange membrane water electrolysis (PEMWE) hydrogen refueling station has undergone thorough economic and environmental analysis. This work intends to fill the gap by presenting the influence of various operating circumstances and design parameters on the economic and environmental aspects of PEMWE based on various behaviors and features (I-V curve) under various scenarios. Profitability analysis (PA) is performed in terms of the net present value (NPV), discounted payback period (DPBP), benefit-cost ratio (BCR), and internal rate of return (IRR) from cumulative discounted cash flow diagrams (CFD). Also, sensitivity analysis (SA) is conducted to assess the impact of different economic factors, while simultaneously establishing CO2 footprint guidelines for optimal operating and design conditions. The findings highlight that enhancing economic feasibility and reducing environmental concerns are simultaneously achievable by increasing cathode pressure, operating temperature, and decreasing membrane thickness. At membrane thicknesses over 100 mu m, the project becomes unprofitable and inefficient at 1.85 V. PEMWE becomes more valuable and sustainable with a current density of 12,000 A/m2 or higher, but it releases more CO2 emissions. Hence, utilizing excess renewable electricity in PEMWE addresses environmental concerns and enhances the overall ecological sustainability of hydrogen production.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Hybrid solar photovoltaic-wind turbine system for on-site hydrogen production: A techno-economic feasibility analysis of hydrogen refueling Station in South Korea's climatic conditions
    Choi, Yosoon
    Bhakta, Shubhashish
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 93 : 736 - 752
  • [42] Techno-economic analysis of photovoltaic-hydrogen refueling station case study: A transport company Tunis-Tunisia
    Barhoumi, El Manaa
    Okonkwo, Paul C.
    Farhani, Slah
    Ben Belgacem, Ikram
    Zghaibeh, Manaf
    Mansir, Ibrahim B.
    Bacha, Faouzi
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (58) : 24523 - 24532
  • [43] Design for on-site Hydrogen Production for Hydrogen Fuel Cell Vehicle Refueling Station at University of Birmingham, UK
    Symes, Daniel
    Al-Duri, Bushra
    Dhir, Aman
    Bujalski, Waldemar
    Green, Ben
    Shields, Alex
    Lees, Matt
    WHEC 2012 CONFERENCE PROCEEDINGS - 19TH WORLD HYDROGEN ENERGY CONFERENCE, 2012, 29 : 606 - 615
  • [44] Numerical investigation of the dispersion features of hydrogen gas under various leakage source conditions in a mobile hydrogen refueling station
    Li, Yongjun
    Wang, Zhirong
    Shi, Xuemeng
    Fan, Rujia
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (25) : 9498 - 9511
  • [45] Design-based risk assessment on an ammonia-derived urban hydrogen refueling station
    Bae, Sang-Hyun
    Lee, Ju-Sung
    Wilailak, Supaporn
    Lee, Ga-Young
    Lee, Chul-Jin
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (09) : 12660 - 12673
  • [46] Design of a Pilot SOFC System for the Combined Production of Hydrogen and Electricity under Refueling Station Requirements
    Perez-Fortes, M.
    Mian, A.
    Srikanth, S.
    Wang, L.
    Diethelm, S.
    Varkaraki, E.
    Mirabelli, I.
    Makkus, R.
    Schoon, R.
    Marechal, F.
    Van herle, J.
    FUEL CELLS, 2019, 19 (04) : 389 - 407
  • [47] Refueling Delay Models in Heterogenous Road Networks for Wireless Communications Base Station Gensets Operating in Extreme Conditions
    Krishnamurthy, Vaidyanathan
    Kwasinski, Alexis
    2021 RESILIENCE WEEK (RWS), 2021,
  • [48] A short-term analysis of hydrogen demand and refueling station cost in Shenzhen China
    Liu, Xiaotong
    Zhang, Shuyang
    Dong, Jun
    Xu, Xinhai
    CLEAN ENERGY FOR CLEAN CITY: CUE 2016 - APPLIED ENERGY SYMPOSIUM AND FORUM: LOW-CARBON CITIES AND URBAN ENERGY SYSTEMS, 2016, 104 : 317 - 322
  • [49] Effects of key design and operating parameters on the performance of the PEM water electrolysis for hydrogen production
    Zhu, Yanxi
    Zhang, Yixiang
    Bin, Shiyu
    Chen, Zeyi
    Zhang, Fanhang
    Gong, Shihao
    Xia, Yan
    Duan, Xiongbo
    RENEWABLE ENERGY, 2024, 235
  • [50] Optimal design and technoeconomic analysis of on-site hydrogen refueling station powered by wind and solar photovoltaic hybrid energy systems
    Ozturk, Reyhan Atabay
    Devrim, Yilser
    RENEWABLE ENERGY, 2025, 245