Real-Time Grid Monitoring and Protection: A Comprehensive Survey on the Advantages of Phasor Measurement Units

被引:21
|
作者
Biswal, Chinmayee [1 ]
Sahu, Binod Kumar [1 ]
Mishra, Manohar [2 ]
Rout, Pravat Kumar [2 ]
机构
[1] Siksha O Anusandhan Deemed Univ, Dept Elect Engn, Bhubaneswar 751030, India
[2] Siksha O Anusandhan Deemed Univ, Dept Elect & Elect Engn, Bhubaneswar 751030, India
关键词
wide-area measurement systems (WAMS); state estimation (SE); synchro-phasor technology; fault detection; phasor measurement units (PMUs); fault localization; power swing; backup protection; renewable energy sources (RESs); AREA BACKUP PROTECTION; SUPPORT VECTOR MACHINE; LOAD SHEDDING SCHEME; POWER-SYSTEM; STATE ESTIMATION; FAULT-DETECTION; IEEE STANDARD; PMU DATA; ISLANDING DETECTION; SYNCHRONIZED PHASOR;
D O I
10.3390/en16104054
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The emerging smart-grid and microgrid concept implementation into the conventional power system brings complexity due to the incorporation of various renewable energy sources and non-linear inverter-based devices. The occurrence of frequent power outages may have a significant negative impact on a nation's economic, societal, and fiscal standing. As a result, it is essential to employ sophisticated monitoring and measuring technology. Implementing phasor measurement units (PMUs) in modern power systems brings about substantial improvement and beneficial solutions, mainly to protection issues and challenges. PMU-assisted state estimation, phase angle monitoring, power oscillation monitoring, voltage stability monitoring, fault detection, and cyberattack identification are a few prominent applications. Although substantial research has been carried out on the aspects of PMU applications to power system protection, it can be evolved from its current infancy stage and become an open domain of research to achieve further improvements and novel approaches. The three principal objectives are emphasized in this review. The first objective is to present all the methods on the synchro-phasor-based PMU application to estimate the power system states and dynamic phenomena in frequent time intervals to observe centrally, which helps to make appropriate decisions for better protection. The second is to discuss and analyze the post-disturbance scenarios adopted through better protection schemes based on accurate and synchronized measurements through GPS synchronization. Thirdly, this review summarizes current research on PMU applications for power system protection, showcasing innovative breakthroughs, addressing existing challenges, and highlighting areas for future research to enhance system resilience against catastrophic events.
引用
收藏
页数:34
相关论文
共 50 条
  • [31] A comprehensive survey of industry practice in real-time systems
    Akesson, Benny
    Nasri, Mitra
    Nelissen, Geoffrey
    Altmeyer, Sebastian
    Davis, Robert I.
    REAL-TIME SYSTEMS, 2022, 58 (03) : 358 - 398
  • [32] A comprehensive survey of industry practice in real-time systems
    Benny Akesson
    Mitra Nasri
    Geoffrey Nelissen
    Sebastian Altmeyer
    Robert I. Davis
    Real-Time Systems, 2022, 58 : 358 - 398
  • [33] Measurement Class Phasor Measurement Unit Compliance for Electrical Grid Monitoring
    Mohan Thakre
    Akbar Ahmad
    Kishor Bhadane
    MAPAN, 2022, 37 : 125 - 135
  • [34] Measurement Class Phasor Measurement Unit Compliance for Electrical Grid Monitoring
    Thakre, Mohan
    Ahmad, Akbar
    Bhadane, Kishor
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2022, 37 (01): : 125 - 135
  • [35] Assessment of Time Synchronization Requirements for Phasor Measurement Units
    Singh, Ravi Shankar
    Hooshyar, Hossein
    Vanfretti, Luigi
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [36] A Bayesian Approach to Real-Time Dynamic Parameter Estimation Using Phasor Measurement Unit Measurement
    Xu, Yijun
    Mili, Lamine
    Chen, Xiao
    Korkali, Mert
    Min, Liang
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2020, 35 (02) : 1109 - 1119
  • [37] A Real-time Monitoring System for Night Glare Protection
    Ma Jun
    Ni Xuxiang
    OPTOELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY, 2010, 7850
  • [38] Optimal Placement of Phasor Measurement Units for State Estimation in Smart Grid
    Var, Hakan
    Turkay, Belgin Emre
    2016 NATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS AND BIOMEDICAL ENGINEERING (ELECO), 2016, : 6 - 10
  • [39] Assessment of compliance of phasor measurement units (PMUs) for smart grid applications
    Kaliappan, P.
    Meera, K. S.
    Selvan, M. P.
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2021, 31 (04)
  • [40] Robust and Economical Placement of Phasor Measurement Units in Indian Smart Grid
    Rihan, Mohd
    Ahmad, Mukhtar
    Beg, M. Salim
    Anees, M. Anas
    2013 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2013,