Real-Time Grid Monitoring and Protection: A Comprehensive Survey on the Advantages of Phasor Measurement Units

被引:16
|
作者
Biswal, Chinmayee [1 ]
Sahu, Binod Kumar [1 ]
Mishra, Manohar [2 ]
Rout, Pravat Kumar [2 ]
机构
[1] Siksha O Anusandhan Deemed Univ, Dept Elect Engn, Bhubaneswar 751030, India
[2] Siksha O Anusandhan Deemed Univ, Dept Elect & Elect Engn, Bhubaneswar 751030, India
关键词
wide-area measurement systems (WAMS); state estimation (SE); synchro-phasor technology; fault detection; phasor measurement units (PMUs); fault localization; power swing; backup protection; renewable energy sources (RESs); AREA BACKUP PROTECTION; SUPPORT VECTOR MACHINE; LOAD SHEDDING SCHEME; POWER-SYSTEM; STATE ESTIMATION; FAULT-DETECTION; IEEE STANDARD; PMU DATA; ISLANDING DETECTION; SYNCHRONIZED PHASOR;
D O I
10.3390/en16104054
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The emerging smart-grid and microgrid concept implementation into the conventional power system brings complexity due to the incorporation of various renewable energy sources and non-linear inverter-based devices. The occurrence of frequent power outages may have a significant negative impact on a nation's economic, societal, and fiscal standing. As a result, it is essential to employ sophisticated monitoring and measuring technology. Implementing phasor measurement units (PMUs) in modern power systems brings about substantial improvement and beneficial solutions, mainly to protection issues and challenges. PMU-assisted state estimation, phase angle monitoring, power oscillation monitoring, voltage stability monitoring, fault detection, and cyberattack identification are a few prominent applications. Although substantial research has been carried out on the aspects of PMU applications to power system protection, it can be evolved from its current infancy stage and become an open domain of research to achieve further improvements and novel approaches. The three principal objectives are emphasized in this review. The first objective is to present all the methods on the synchro-phasor-based PMU application to estimate the power system states and dynamic phenomena in frequent time intervals to observe centrally, which helps to make appropriate decisions for better protection. The second is to discuss and analyze the post-disturbance scenarios adopted through better protection schemes based on accurate and synchronized measurements through GPS synchronization. Thirdly, this review summarizes current research on PMU applications for power system protection, showcasing innovative breakthroughs, addressing existing challenges, and highlighting areas for future research to enhance system resilience against catastrophic events.
引用
收藏
页数:34
相关论文
共 50 条
  • [1] Virtualization of Synchronized Phasor Measurement Units Within Real-Time Simulators for Smart Grid Applications
    Al-Hammouri, A. T.
    Nordstrom, L.
    Chenine, M.
    Vanfretti, L.
    Honeth, N.
    Leelaruji, R.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [2] Development and Implementation of a Phasor Measurement Unit for Real-Time Monitoring, Control and Protection of Power Systems
    Salehi, V.
    Mazloomzadeh, A.
    Mohammed, O.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [3] Performance of Phasor Measurement Units for Wide Area Real-Time Control
    Laverty, David M.
    Morrow, D. John
    Best, Robert
    Crossley, Peter A.
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 4282 - 4286
  • [4] Accurate Real-Time Measurements of the Smart Grid Phasor Measurement Unit Parameters
    Rahmati, Abouzar
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (16) : 1815 - 1824
  • [5] A Real-time Phasor Measurement Algorithm Based On Statistics
    Feng Yuan
    Xia Li
    Wang Li-ming
    Cai Lun
    INTERNATIONAL CONFERENCE ON SOLID STATE DEVICES AND MATERIALS SCIENCE, 2012, 25 : 1110 - 1117
  • [6] A Survey on the Application of Phasor Measurement Units to the Protection of Transmission and Smart Distribution Systems
    Menezes, T. S.
    Barra, P. H. A.
    Dizioli, F. A. S.
    Lacerda, V. A.
    Fernandes, R. A. S.
    Coury, D. V.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2024, 52 (08) : 1379 - 1396
  • [7] Real-time voltage stability assessment using phasor measurement units: Influence of synchrophasor estimation algorithms
    Thilakarathne, Chathura
    Meegahapola, Lasantha
    Fernando, Nuwantha
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 119
  • [8] Comparative Study Between Model-in-the-loop Offline and Real-time Simulations for Phasor Measurement Units
    Muhayimana, Obed
    Laamim, Mohammed
    Aljazaeri, Ali
    Rochd, Abdelilah
    Toman, Petr
    2024 24TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING, EPE 2024, 2024, : 150 - 155
  • [9] Real-time voltage stability monitoring and transmission parameter estimation based on phasor measurement data using real-time digital simulator
    Ko B.
    Nam S.
    Koo B.
    Kang S.
    Shin J.
    Transactions of the Korean Institute of Electrical Engineers, 2020, 69 (11): : 1626 - 1632
  • [10] Real-Time Monitoring & Protection of Power Transformer to Enhance Smart Grid Reliability
    Chothani, N. G.
    Raichura, M. B.
    Patel, D. D.
    Mistry, K. D.
    2018 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC), 2018,