共 50 条
Next Generation Sequencing for miRNA Detection on the Exhaled Breath Condensate: A Pilot Study
被引:4
|作者:
Cherchi, Roberto
[1
]
Cusano, Roberto
[2
]
Orru, Sandro
[3
,4
]
Ferrari, Paolo A.
[1
]
Massidda, Matteo
[2
]
Fotia, Giorgio
[2
]
De Matteis, Sara
[4
]
Cocco, Pierluigi
[5
]
机构:
[1] Hosp G Brotzu, Operat Unit Thorac Surg, Cagliari, Italy
[2] CRS4 NGS Core, Polaris Res Pk,Pula, Cagliari, Italy
[3] Hlth Agcy Sardinia, Hosp Binaghi, Operat Unit Med Genet, Cagliari, Italy
[4] Univ Cagliari Monserrato, Dept Med Sci & Publ Hlth, Cagliari, Italy
[5] Univ Manchester, Ctr Occupat & Environm Hlth, Hlth Serv Res & Primary Care, Div Populat Hlth, Manchester, England
来源:
关键词:
miRNA;
next generation sequencing;
biomarkers;
exhaled breath condensate;
MICRORNAS;
SIGNATURE;
PLASMA;
RNAS;
D O I:
10.1177/25168657231160985
中图分类号:
Q3 [遗传学];
学科分类号:
071007 ;
090102 ;
摘要:
INTRODUCTION: Exhaled breath condensate (EBC) sampling has been suggested as a less-invasive and cost-effective method to detect biological macromolecules, including miRNA. To explore the feasibility of its use as a biomarker of early effects of asbestos exposure, we conducted a preliminary test on male volunteers by comparing the miRNA profile in the EBC and the plasma using 2 different sequencing platforms. METHODS: Six male volunteers, all retired and unexposed to dust or fumes, participated in the test. RNA was extracted from 200 mu L EBC samples and same-size plasma samples. Sample aliquots were processed in 2 laboratories using 2 different sequencing platforms: a MiSeq Illumina((R)) platform and a more performing HiSeq Illumina((R)) platform. RESULTS: The HiSeq3000((R)) sequencing platform identified twice as many unique molecular indexes (UMI)-validated miRNA as the MiSeq((R)) platform. The Spearman's correlation coefficient between EBC counts and plasma counts was significant in 5/6 subjects with either platform (MiSeq((R)) = 0.128-0.508, P = .026-<.001; HiSeq((R)) = 0.156-0.412, P = .001-<.001). The intraclass correlation coefficient confirmed the consistency of the miRNA profile over the 6 participants with both biospecimens. Exploring the agreement between the EBC and plasma samples with Bland-Altman plots showed that using the HiSeq3000((R)) platform substantially improved the EBC miRNA detection rate. CONCLUSION: Our preliminary study confirms that, when using the HiSeq((R)) sequencing platform, EBC sampling is a suitable, non-invasive method to detect the miRNA profile in healthy subjects.
引用
收藏
页数:7
相关论文