Optimization of an axial-flow mine ventilation fan based on effects of design parameters

被引:2
|
作者
Fakhari, Seyyed Mojtaba [1 ]
Mrad, Hatem [1 ]
机构
[1] Univ Quebec Abitibi Temiscamingue, Sch Engn, Rouyn Noranda, PQ J9X 5E4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Mine ventilation; Optimization; Axial -flow fan; Fluid-structure interaction; Design of experiments; PERFORMANCE; AIRFOIL;
D O I
10.1016/j.rineng.2023.101662
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Underground mining safety relies heavily on ventilation, which is energy and maintenance intensive. An opti-mization method for an axial-flow Chinook ventilation fan, analyzing parameters like angle of attack, tip clearance, rotation speed, hub-to-tip ratio, and rotor blade count using Design of Experiments (DOE) and regression is proposed. The numerical solutions are confirmed with experimental data. Considering a Mach number of 0.4, compressible flow conditions are analyzed using a two-equation turbulence model. During stall, fan efficiency drops to 47 %. High fatigue probability is observed at the blade-root intersection in stall condi-tions. The optimization pinpoints several operational configurations that meet the required performance while preserving the fan's structure. A particular off-design optimal point indicates that reducing the blade count and decreasing the tip-clearance lead to an average performance improvement of 9 %, with significant benefits in noise, cost, weight, and energy consumption. The numerical forecasts demonstrate precision with an average discrepancy of less than 5 %.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Collaborative optimization algorithm on axial-flow pump blade design
    Shi, Lijian
    Tang, Fangping
    Lei, Cuicui
    Yang, Hua
    Yang, Fan
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2014, 30 (17): : 93 - 100
  • [32] OPTIMIZATION FOR ROTOR BLADES OF TANDEM DESIGN FOR AXIAL-FLOW COMPRESSORS
    BAMMERT, K
    STAUDE, R
    JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1980, 102 (02): : 369 - 375
  • [33] THE EFFECT OF TIP CLEARANCE ON THE PERFORMANCE OF AN AXIAL-FLOW FAN
    VENTER, SJ
    KROGER, DG
    ENERGY CONVERSION AND MANAGEMENT, 1992, 33 (02) : 89 - 97
  • [34] Optimization design method based on parameter reduction and active subspaces: Redistribution of chordwise loading at blade tips in a transonic axial-flow fan
    Ma, Tao
    Lu, Hanan
    Li, Qiushi
    PHYSICS OF FLUIDS, 2024, 36 (09)
  • [35] Flow Characterization in Mine Ventilation Fan Blade Design Using CFD
    Hassen, Anwar Endris
    JOURNAL OF SUSTAINABLE MINING, 2021, 20 (03): : 144 - 156
  • [36] On the Nature of Transonic Shock Buffet in an Axial-Flow Fan
    Majhi, Jyoti Ranjan
    Venkatraman, Kartik
    AIAA JOURNAL, 2023, 61 (12) : 5390 - 5403
  • [37] Application of casing treatment to an industrial axial-flow fan
    Hill, SD
    Elder, RL
    McKenzie, AB
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 1998, 212 (A4) : 225 - 233
  • [38] Efficiency of an Axial-Flow Fan with Twisted Blades.
    Parafiniuk, Jan
    1600, (35):
  • [39] ROTOR WAKE CHARACTERISTICS OF A TRANSONIC AXIAL-FLOW FAN
    HATHAWAY, MD
    GERTZ, JB
    EPSTEIN, AH
    STRAZISAR, AJ
    AIAA JOURNAL, 1986, 24 (11) : 1802 - 1810
  • [40] Application of casing treatment to an industrial axial-flow fan
    Hill, S.D.
    Elder, R.L.
    McKenzie, A.B.
    Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 1998, 212 (4 A4): : 225 - 233