Design and optimization of MED-TVC desalination plant using mathematical modeling coupled with response surface methodology

被引:4
|
作者
Abdi-Khanghah, Mahdi [1 ]
Bazooyar, Bahamin [2 ]
Gonbadi, Maryam [3 ]
Wu, Kevin C. -W. [4 ,5 ]
机构
[1] Tarbiat Modares Univ, Dept Chem Engn, Tehran, Iran
[2] Brunel Univ London, Mech & Aerosp Engn, Uxbridge UB8 3PH, England
[3] Shiraz Univ, Fac Adv Technol, Dept Nanochem Engn, Shiraz, Iran
[4] Natl Taiwan Univ, Dept Chem Engn, 1,Sec 4,Roosevelt Rd, Taipei 10617, Taiwan
[5] Yuan Ze Univ, Dept Chem Engn & Mat Sci, Taoyuan, Taiwan
关键词
MED-TVC; Mathematical modeling; Design parameter; RSM optimization; Parametric study; WATER;
D O I
10.1016/j.jtice.2023.105187
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Background: The ever-increasing demand for a better living condition and clean water resources leads has spawned a tremendous research effort for new and optimized water desalination technologies.Methods: To this end, an innovative Multi Effect Desalination-Thermal Vapor Compression (MED-TVC) water desalination plant is designed using mathematical modeling for installation in the Persian Gulf. The developed models for the new MED-TVC plant include governing mass, energy and thermodynamic equations are validated against the dataset obtained from the installed MED-TVC plant, then are used to reach the general aim of research or optimize the operation of the MED-TVC plant. Mentioned governing equations were solved to find (GOR), surface area (Ad), and heat transfer rate (Q) for different desalination plants. Then, response surface methodology (RSM) was used for finding optimum operational parameter to reach the optimum targets. The dataset required for the analysis and optimization of MED-TVC based on design parameters and input factors are generated with in-house code considering flashing box and losses due to pressure losses. Considering thermodynamic losses and governing equation of flashing boxes followed by optimizing design parameters such as gain output ratio (GOR), surafe area (Ad), and heat transfer rate (Q) were conducted for the first time in this research.Significant finding: The findings demonstrate maximum relative error percent for design parameters of both in-dustrial desalination plant corresponds to the specific heat transfer area (Ad) of GHESHM (-1.6 %) and specific heat consumption (Q) of RABIGH (-4.44 %). Moreover, gain output ratio (GOR), Ad and Q related to optimized MED-TVC unit are 9.86, 58.96, and 213.66, respectively which are more suitable than that of industrial GHESHM and RABIGH desalination unit. Also, sensitivity analysis of results illustrates that increasing motive steam pressure causes the GOR reduction; however, increasing feed water temperature and motive steam flow rate leads to increasing GOR.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Energy and Exergy Analyses of a PWR-Type Nuclear Power Plant Coupled with an ME-TVC-MED Desalination System
    Triki, Zakaria
    Menasri, Rabah
    Bouaziz, Mohamed Najib
    Tahraoui, Hichem
    Kebir, Mohammed
    Amrane, Abdeltif
    Zhang, Jie
    Mouni, Lotfi
    SUSTAINABILITY, 2023, 15 (10)
  • [32] Seawater desalination plant using nuclear heating reactor coupled with MED process
    WU Shao-Rong
    DONG Duo
    ZHANG Da-Fang
    WANG Xiu-Zhen (Institute of Nuclear Energy Technology
    NuclearScienceandTechniques, 2000, (01) : 6 - 12
  • [33] Seawater desalination plant using nuclear heating reactor coupled with MED process
    Wu, Shaorong
    Dong, Duo
    Zhang, Dafang
    Wang, Xiuzhen
    Nuclear Science and Techniques/Hewuli, 2000, 11 (01): : 6 - 12
  • [34] Thermoeconomic analysis of an integrated multi-effect desalination thermal vapor compression (MED-TVC) system with a trigeneration system using triple-pressure HRSG
    Hadi Ghaebi
    Ghader Abbaspour
    Heat and Mass Transfer, 2018, 54 : 1337 - 1357
  • [35] Modeling and optimization of sand crushing plant using experimental design methodology
    Benyessad, Djamel
    Arkoub, Hamid
    Seghir, Abdelghani
    WORLD JOURNAL OF ENGINEERING, 2019, 16 (04) : 487 - 496
  • [36] Modeling and optimization of a solar forward osmosis pilot plant by response surface methodology
    Khayet, M.
    Sanmartino, J. A.
    Essalhi, M.
    Garcia-Payo, M. C.
    Hilal, N.
    SOLAR ENERGY, 2016, 137 : 290 - 302
  • [37] Thermoeconomic analysis of an integrated multi-effect desalination thermal vapor compression (MED-TVC) system with a trigeneration system using triple-pressure HRSG
    Ghaebi, Hadi
    Abbaspour, Ghader
    HEAT AND MASS TRANSFER, 2018, 54 (05) : 1337 - 1357
  • [38] Design and optimization of a siphon turbine using the response surface methodology
    Guerra, Juliana
    Velasquez, Laura
    Rubio-Clemente, Ainhoa
    Jaramillo, Leyla
    Chica, Edwin
    RESULTS IN ENGINEERING, 2024, 22
  • [39] Robust design for torque optimization using response surface methodology
    Gao, XK
    Low, TS
    Liu, ZJ
    Chen, SX
    IEEE TRANSACTIONS ON MAGNETICS, 2002, 38 (02) : 1141 - 1144
  • [40] Optimization of laccase production using response surface methodology coupled with differential evolution
    Bhattacharya, Sukanta Shekhar
    Garlapati, Vijay Kumar
    Banerjee, Rintu
    NEW BIOTECHNOLOGY, 2011, 28 (01) : 31 - 39