Four-year visual outcomes and optical quality of SMILE and implantable collamer lens V4c (EVO-ICL) implantation for high myopia: a retrospective study

被引:8
|
作者
Luo, Wuqiang [1 ]
Aruma, Aruma [2 ]
Li, Meiyan [2 ]
Wang, Jing [3 ]
Xie, Jing [4 ]
Xiao, Xin [1 ]
Shen, Yang [2 ]
Niu, Lingling [2 ]
Wang, Xiaoying [2 ]
Zhou, Xingtao [2 ,5 ]
机构
[1] Peoples Hosp Guangxi Zhuang Autonomous Reg, Visual Sci & Optometry Ctr, Nanning 530021, Guangxi, Peoples R China
[2] Fudan Univ, Shanghai Res Ctr Ophthalmol & Optometry, Dept Ophthalmol, NHC Key Lab Myopia,Eye & ENT Hosp, Shanghai 200433, Peoples R China
[3] Wuhan Univ, Aier Eye Hosp Grp, Aier Eye Hosp, Wuhan 430063, Hubei, Peoples R China
[4] Longgang ENT Hosp, Inst ENT Shenzhen, Dept Ophthalmol, Shenzhen Key Lab ENT, Shenzhen 518172, Peoples R China
[5] Fudan Univ, Dept Ophthalmol & Optometry, Myopia Key Lab Hlth Minist, Eye & ENT Hosp, 83 Fenyang Rd, Shanghai 200031, Peoples R China
基金
中国国家自然科学基金;
关键词
High myopia; Small incision lenticule extraction; Implantable collamer lens V4c; Visual quality; PHAKIC INTRAOCULAR-LENS; CENTRAL HOLE; MODERATE;
D O I
10.1186/s12886-023-03050-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo compare the 4-year visual outcomes of implantable collamer lens V4c (EVO-ICL) implantation and small incision lenticule extraction (SMILE) for high myopia and astigmatism.MethodsThis retrospective case study included 64 eyes of 40 patients. These patients with preoperative manifest refraction spherical equivalent (SE) between - 6.00 and - 10.00 diopters (D) were screened from the database of SMILE and EVO-ICL implantation procedures in 2015. The ICL group [32 eyes of 19 patients (mean age, 29.6 & PLUSMN; 6.3 years); mean SE, -8.71 & PLUSMN; 1.06 D] and SMILE group [32 eyes of 21 patients (mean age, 27.7 & PLUSMN; 5.6 years); mean SE, -8.35 & PLUSMN; 0.65D] were compared. All patients were then prospectively examined at a four-year follow-up for routine postoperative examinations, higher-order ocular aberrations, retinal image quality and a questionnaire.ResultsThe safety indexes were 1.15 & PLUSMN; 0.14 and 1.22 & PLUSMN; 0.21 (P = 0.36) for the SMILE and ICL groups, respectively. No eyes lost two or more lines of CDVA in either group. The efficacy indexes were 0.97 & PLUSMN; 0.16 and 0.96 & PLUSMN; 0.19 (P = 0.87), respectively. Twenty-three eyes (72%) in ICL and 26 eyes (81%) in SMILE groups were within & PLUSMN; 0.5 D of the attempted SE (P < 0.01). ICL-treated eyes had significantly less spherical aberration and coma (P < 0.01 and < 0.05, respectively) postoperatively. Halos were the prevalent visual disturbance in both groups.ConclusionSMILE and EVO-ICL implantation provided safe and effective correction of high myopia. SMILE showed slightly better long-term predictability. Mild postoperative visual disturbances were observed after ICL and SMILE at 4-year follow-up.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Visual outcomes after small incision lenticule extraction and implantable collamer lens V4c for moderate myopia: 1-year results
    Aruma Aruma
    Meiyan Li
    Joanne Choi
    Huamao Miao
    Ruoyan Wei
    Danjuan Yang
    Peijun Yao
    Ling Sun
    Xiaoying Wang
    Xingtao Zhou
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 2431 - 2440
  • [22] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Lin, Qinghong
    Yang, Dong
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [23] Visual outcomes after small incision lenticule extraction and implantable collamer lens V4c for moderate myopia: 1-year results
    Aruma, Aruma
    Li, Meiyan
    Choi, Joanne
    Miao, Huamao
    Wei, Ruoyan
    Yang, Danjuan
    Yao, Peijun
    Sun, Ling
    Wang, Xiaoying
    Zhou, Xingtao
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (08) : 2431 - 2440
  • [24] Long-term observation on safety and visual quality of implantable collamer lens V4c implantation for myopia correction: a 5-year follow-up
    Chen, Xiao
    Li, Li
    Rao, Jing
    Chen, Yue-Xi
    Gao, Yang
    Huang, Rui-Xue
    Zhou, Qi-Zhi
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2023, 16 (07) : 1123 - 1129
  • [25] Long-Term Outcomes of Retinal Detachment in Phakic Eyes After Implantation of Implantable Collamer Lens V4c for High Myopia Correction
    Xu, Weiwei
    Song, Zhou
    Huang, Yifei
    Tao, Ye
    Wang, Junqing
    Wang, Liqiang
    Li, Zhaohui
    FRONTIERS IN MEDICINE, 2020, 7
  • [26] Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia
    Cao, Weifang
    Zhang, Suhua
    Liu, Qian
    Zhou, Jing
    Yuan, Xiaoyong
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (11) : 4111 - 4120
  • [27] Comparison of long-term visual quality after keratorefractive lenticule extraction and implantable collamer lens V4c for high myopia
    Zhan, Biyun
    Huang, Yangyi
    Chen, Xun
    Aruma, Aruma
    Cheng, Mingrui
    Wang, Xiaoying
    Zhou, Xingtao
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (11): : 1157 - 1164
  • [28] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Qinghong Lin
    Dong Yang
    Xingtao Zhou
    BMC Ophthalmology, 22
  • [29] Long-term observation on safety and visual quality of implantable collamer lens V4c implantation for myopia correction: a 5-year follow-up
    Xiao Chen
    Li Li
    Jing Rao
    Yue-Xi Chen
    Yang Gao
    Rui-Xue Huang
    Qi-Zhi Zhou
    International Journal of Ophthalmology, 2023, (07) : 1123 - 1129
  • [30] Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia
    Weifang Cao
    Suhua Zhang
    Qian Liu
    Jing Zhou
    Xiaoyong Yuan
    International Ophthalmology, 2023, 43 : 4111 - 4120