Wearable Optical Fiber Beat Frequency Digital Sensing System for Real-Time Non-Invasive Multiple Human Physiological Parameters Monitoring

被引:8
|
作者
Guo, Yu [1 ]
Tong, Xingxing [1 ]
Shen, Yanxia [1 ]
Wu, Haodong [2 ]
机构
[1] Jiangnan Univ, Sch Internet Things Engn, Wuxi 214000, Jiangsu, Peoples R China
[2] Nanjing Univ, Sch Phys, Nanjing 210093, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Human physiological information; longitudinal mode beat frequency signal; optical fiber sensing; polarization laser modes' beat frequency signal; variational mode decomposition; VITAL SIGNS; SENSOR; STRAIN; TEMPERATURE; DEVICE; LASER;
D O I
10.1109/JLT.2023.3238476
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An optical fiber beat frequency sensing system (BFSS) for multiple human physiological parameters monitoring is proposed. To the best of the authors' knowledge, this is the first BFSS ever reported for multiple human physiological parameters monitoring. By utilizing both fiber Bragg grating (FBG) and fiber laser sensor, not only a low frequency vibration detection with the lowest detectable frequency of 0.25 Hz can be achieved for respiration, heartbeat and pulse signals monitoring, but also human body temperature can be monitored at the same time. Two kinds of beat frequency signals (BFS) are generated in the sensing systems including both polarization laser modes' beat frequency (PMBF) signals and longitudinal mode beat frequency (LMBF) signals. The PMBF signal is utilized for respiration, heartbeat and pulse signals monitoring. Variational mode decomposition (VMD) algorithm is utilized to decompose the monitored time-frequency PMBF signals into single-component respiration, heartbeat and pulse signals. The central frequencies of those signals are obtained by fast Fourier transform (FFT). The LMBF signal is utilized for human body temperature sensing. Measurement results demonstrate that the wearable optical fiber beat frequency digital monitoring system has a simple structure, high signal-to-noise ratio (SNR), stability, accuracy and muti-parameters sensing capability including respiration, heartbeat, pulse and human body temperature without mutual interference.
引用
收藏
页码:2911 / 2920
页数:10
相关论文
共 50 条
  • [41] Body Heat Powered Wirelessly Wearable System for Real-time Physiological and Biochemical Monitoring
    An, Zijian
    Fu, QiQi
    Lv, Jingjiang
    Zhou, Tao
    Wu, Yue
    Lu, Yanli
    Liu, Guang
    Shi, Zhenghan
    li, Xin
    Zhang, Fenni
    Liu, Qingjun
    ADVANCED FUNCTIONAL MATERIALS, 2023, 33 (34)
  • [42] Development of a non-invasive real-time measurement system of wave intensity
    Harada, A
    Okada, T
    Sugawara, M
    Niki, K
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1517 - 1520
  • [43] A WEARABLE BIOFEEDBACK SYSTEM SUPPORTING REAL-TIME PACED BREATHING TRAINING AND PHYSIOLOGICAL MONITORING
    Zhang, Zheng-Bo
    Wu, Hao
    Zheng, Jie-Wen
    Wang, Wei-Dong
    Wang, Bu-Qing
    Liu, Hong-Yun
    Wang, Guo-Jing
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2013, 25 (02):
  • [44] A Real-Time Wearable Physiological Monitoring System for Home-Based Healthcare Applications
    Jeong, Jin-Woo
    Lee, Woochan
    Kim, Young-Joon
    SENSORS, 2022, 22 (01)
  • [45] Non-invasive smart health monitoring system based on optical fiber interferometers
    Yu, Changyuan
    Xu, Wei
    Zhang, Na
    Yu, Cheungchuen
    2017 16TH INTERNATIONAL CONFERENCE ON OPTICAL COMMUNICATIONS & NETWORKS (ICOCN 2017), 2017,
  • [46] Real-time non-invasive monitoring of intravitreal drug release from porous silicon (pSi) by digital camera
    Hou, Huiyuan
    Nieto, Alejandra
    Wang, Chengyun
    Belghith, Akram
    Freeman, William R.
    Sailor, Michael J.
    Cheng, Lingyun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [47] A real-time surface EMG decomposition system for non-invasive human-machine interfaces
    Barsakcioglu, Deren Y.
    Farina, Dario
    2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, : 459 - 462
  • [48] Enabling non-invasive and real-time human-machine interactions based on wireless sensing and fog computing
    Zhu Wang
    Xinye Lou
    Zhiwen Yu
    Bin Guo
    Xingshe Zhou
    Personal and Ubiquitous Computing, 2019, 23 : 29 - 41
  • [49] A software package for non-invasive, real-time beat-to-beat monitoring of stroke volume, blood pressure, total peripheral resistance and for assessment of autonomic function
    Gratze, G
    Fortin, J
    Holler, A
    Grasenick, K
    Pfurtscheller, G
    Wach, P
    Schonegger, J
    Kotanko, P
    Skrabal, F
    COMPUTERS IN BIOLOGY AND MEDICINE, 1998, 28 (02) : 121 - 142
  • [50] Algorithm for Real-Time Pulse Wave Detection Dedicated to Non-Invasive Pulse Sensing
    Iliev, Ivo
    Nenova, Bistra
    Jekova, Irena
    Krasteva, Vessela
    2012 COMPUTING IN CARDIOLOGY (CINC), VOL 39, 2012, 39 : 777 - 780