Structural Performance of Internally Stiffened Double-Skinned Profiled Composite Walls with Openings

被引:3
|
作者
Hilo, Salam J. [1 ]
Hamood, Mohammed J. [1 ]
Al-Zuhairi, Alaa Hussein [2 ]
Zand, Ahmed W. Al [3 ]
Kaish, A. B. M. A. [3 ]
Ali, Mustafa M. [4 ]
Faris, Marwah M. [5 ]
Badaruzzaman, Wan Hamidon W. [3 ]
机构
[1] Univ Technol Iraq, Civil Engn Dept, Baghdad, Iraq
[2] Univ Baghdad, Dept Civil Engn, Baghdad, Iraq
[3] Univ Kebangsaan Malaysia, Dept Civil Engn, Bangi 43600, Malaysia
[4] Univ Kerbala, Coll Engn, Dept Civil Engn, Karbala, Iraq
[5] Chalmers Univ Technol, Dept Architecture & Civil Engn, S-41296 Gothenburg, Sweden
关键词
double-skinned profile; profiled steel sheet; composite wall; concrete-filled steel wall; cold form steel; finite element; BEHAVIOR; STRENGTH;
D O I
10.3390/buildings13061499
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The double-skin profiled composite wall (DSPCW) system, filled with concrete material, is favorable in modern structures due to its high strength and ductility. Openings may be required within this composite wall (DSPCW) for various reasons, similar to a conventional bearing wall, which can lead to a reduction in bearing capacity. Therefore, to avoid changes in the geometry, materials, and thickness of this DSPCW wall, a new internally stiffening concept has been suggested by providing embedded cold-formed steel tube (CFST) columns. For this purpose, two full-scale DSPCW specimens were tested under static axial load, one of which was fabricated with a large opening size and stiffened with two octagonal CFST columns, while the other was designed without an opening and served as a control wall specimen. The results showed that the stiffened DSPCW with an opening achieved a slightly lower ultimate bearing strength (-9.4%) than the control wall specimen, with no reduction in the ductility behavior. Furthermore, several finite element models of DSPCW have been analyzed and designed to investigate additional parameters that were not experimentally tested, including the effects of the embedded CFST column's shape and different types of internal stiffeners longitudinally provided inside these columns. The numerical investigation confirmed that the embedded CFST column with an octagonal cross-section was more efficient compared to the hexagonal and rectangular shapes by about 11% and 18.4%, respectively. Furthermore, using internal steel stiffeners for embedded tubes with a T-shape improved the axial bearing capacity of the DSPCW with an opening slightly higher than the corresponding stiffened walls with other investigated stiffener shapes (V-shaped, U-shaped, and L-shaped).
引用
收藏
页数:24
相关论文
共 50 条
  • [31] Analytical Investigation on Concrete Filled Double-Skinned Steel Tubular Column Composite Frame With Bolted End-Plate Connections
    He, Wenhui
    Yang, Chunqiang
    Yi, Yuanye
    Tang, Zhihan
    He, Pengchen
    Weng, Haibing
    ADVANCES IN CIVIL INFRASTRUCTURE ENGINEERING, PTS 1 AND 2, 2013, 639-640 : 220 - +
  • [32] Double-skinned forward osmosis membranes based on layer-by-layer assembly-FO performance and fouling behavior
    Qi, Saren
    Qiu, Chang Quan
    Zhao, Yang
    Tang, Chuyang Y.
    JOURNAL OF MEMBRANE SCIENCE, 2012, 405 : 20 - 29
  • [33] Preparation and characterization of double-skinned FO membranes: Comparative performance between nanofiber and phase conversion membranes as supporting layers
    Ma, Cong
    Tian, Yaoyao
    Liu, Xinying
    Li, Yajing
    Zhang, Pengda
    Chu, Xiuru
    Wang, Liang
    Zhao, Bin
    Zhang, Zhaohui
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2022, 164 : 807 - 817
  • [34] Improving seismic performance of composite steel plate shear walls containing openings
    Meghdadaian, Mohammad
    Ghalehnovi, Mansour
    JOURNAL OF BUILDING ENGINEERING, 2019, 21 : 336 - 342
  • [35] Structural performance of RC beams with openings reinforced with composite materials
    Shaheen, Yousry B. I.
    Mahmoud, Ashraf M.
    STRUCTURAL ENGINEERING AND MECHANICS, 2022, 83 (04) : 475 - 493
  • [36] Hysteretic performance of dovetail profiled steel-concrete composite sandwich shear walls
    Zhang, Sumei
    Huang, Zhenfeng
    Guo, Lanhui
    ENGINEERING STRUCTURES, 2022, 256
  • [37] Performance of dovetail profiled steel concrete composite sandwich walls under axial compression
    Zhang, Sumei
    Huang, Zhenfeng
    Guo, Lanhui
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 309
  • [38] Structural performance assessment of large unstiffened openings in steel plate shear walls
    Darvishi, Hadi
    Mofid, Massood
    ENGINEERING STRUCTURES, 2021, 247
  • [39] On performance and anti-fouling properties of double-skinned thin film nanocomposite hollow fiber membranes in forward osmosis system
    Alihemati, Z.
    Hashemifard, S. A.
    Matsuura, T.
    Ismail, A. F.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2023, 193 : 340 - 352
  • [40] A Numerical Study on the Effect of Position and Number of Openings on the Performance of Composite Steel Shear Walls
    Badarloo, Baitollah
    Jafari, Faezeh
    BUILDINGS, 2018, 8 (09)