Research Progress on Audible Noise Emitted from HVDC Transmission Lines

被引:4
|
作者
Li, Li [1 ]
Meng, Wei [1 ]
Li, Qi [2 ,3 ]
Wang, Yifan [1 ]
Zheng, Xiaoguang [1 ]
Wang, Hongbin [4 ]
机构
[1] Elect Power Res Inst Guangdong Power Grid Co Ltd, Key Lab Environm Protect Guangdong Power Grid Co L, Guangzhou 510080, Peoples R China
[2] Xuefeng Mt Energy Equipment Safety Natl Observat &, Chongqing 400044, Peoples R China
[3] Univ Manchester, Dept Elect & Elect Engn, Manchester M13 9PL, England
[4] China Southern Power Grid, Guangzhou Power Supply Bur Guangdong Power Grid Co, Guangzhou 510620, Peoples R China
关键词
DC transmission line; audible noise; corona discharge; overview; CORONA CHARACTERISTICS; WAVE GENERATION; CAGE; BUNDLES; MODEL;
D O I
10.3390/en16124614
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The audible noise (AN) of DC transmission lines is a crucial factor affecting environmental assessment and electromagnetic design. In recent years, the public has paid increasing attention to the audible noise after the emergence of the HVDC technique. This paper emphatically reviewed the work investigating audible noise characteristics in both time and frequency domains, especially the correlation between sound and discharge. The proposed mechanisms of DC audible noise and the mitigating techniques are summarized, including the noise generation process, the physical models, the measurement method, and the mitigating technologies. It is found that the existing literature mainly focused on the prediction and characteristics of AN, the environmental factors which influence AN, and the methods to minimize AN emission. However, existing achievements still need to be improved to fully understand the mechanism of AN generation and solve the adaptability problem of AN prediction methods. The following aspects are valuable in future research: The correlation between audible noise and other corona effects will help solve the problem of difficulty in measuring audible noise in field condition; The corona discharge mechanism and weather resistance anti-corona coating when raindrops are attached to the surface of the transmission line, which will help guide the development and application of anti-corona coatings for the transmission line. Future research should also understand the mechanism of sound wave generation when considering the space charge effect.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] MEASUREMENT AND ANALYSIS OF AUDIBLE NOISE FROM OPERATING 765 KV TRANSMISSION-LINES
    POPECK, RA
    KNAPP, RF
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (04): : 2138 - 2148
  • [22] HUMAN RESPONSE TO AUDIBLE NOISE FROM HIGH-VOLTAGE TRANSMISSION-LINES
    MOLINO, JA
    ZERDY, GA
    LERNER, ND
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 64 : S127 - S127
  • [23] Long-term evaluation of HVDC transmission line audible noise and its correlation with background noise
    Shin, Koo Yong
    Oh, Joon Arm
    Kwon, Gu Min
    Ju, Mun No
    Woo, Jeong Min
    AIP ADVANCES, 2019, 9 (09):
  • [25] Environmental effect of high voltage AC transmission lines audible noise
    Al-Faraj, MA
    Shwehdi, MH
    Farag, AS
    IECEC-97 - PROCEEDINGS OF THE THIRTY-SECOND INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4: VOL.1: AEROSPACE POWER SYSTEMS AND TECHNOL; VOL 2: ELECTROCHEMICAL TECHNOL, CONVERSION TECHNOL, THERMAL MANAGEMENT; VOLS 3: ENERGY SYSTEMS, RENEWABLE ENERGY RESOURCES, ENVIRONMENTAL IMPACT, POLICY IMPACTS ON ENERGY; VOL 4: POST DEADLINE PAPERS, INDEX, 1997, : 2082 - 2087
  • [26] The Influence of Wind on the Audible Noise of Ultra HVDC Transmission Line in High Altitude Area
    Li, Min
    Zeng, Rong
    Yang, Dawei
    Yu, Zhanqing
    Li, Ruihai
    Liu, Lei
    Zhang, Bo
    Zhang, Huaying
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 1668 - 1671
  • [27] Evaluation of audible noise predicting formulas for AC UHV transmission lines
    Yu, Ji-Hui
    Yang, Yue
    He, Jian
    Yang, Guang
    Ji, Juan
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (03): : 451 - 456
  • [28] Influence of Humidity on Spectrum Characteristics of Audible Noise of DC Transmission Lines
    Yi, Yong
    Chen, Zhengying
    Wang, Liming
    2016 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2016, : 275 - 278
  • [29] Calculation of electric field and audible noise from transmission lines with non-parallel conductors
    Liu, YL
    Zaffanella, LE
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) : 1492 - 1497
  • [30] Mechanism and theoretical model for corona audible noise from high voltage AC transmission lines
    Di, Zelong
    Wu, Jiuhui
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2012, 46 (08): : 128 - 132