The Effect of Wearable-Based Real-Time Feedback on Running Injuries and Running Performance A Randomized Controlled Trial

被引:5
|
作者
Van Hooren, Bas [1 ]
Plasqui, Guy [1 ]
Meijer, Kenneth [1 ]
机构
[1] Maastricht Univ, Med Ctr, NUTRIM Sch Nutr & Translat Res Metab, Dept Nutr & Movement Sci, Univ Singel 50, NL-6229 ER Maastricht, Netherlands
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2024年 / 52卷 / 03期
关键词
biofeedback; biomechanics; motivation; technology; wearables; running; FOOT STRIKE; RUNNERS; STRESS; CONSENSUS; BIOMECHANICS; DEFINITION; KINEMATICS; PROGRAM; PATTERN; ECONOMY;
D O I
10.1177/03635465231222464
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Running technique and running speed are considered important risk factors for running injuries. Real-time feedback on running technique and running speed by wearables may help reduce injury risk. Purpose: To investigate whether real-time feedback on spatiotemporal metrics and relative speed by commercially available pressure-sensitive insoles would reduce running injuries and improve running performance compared with no real-time feedback. Study Design: Randomized controlled trial; Level of evidence, 1. Methods: A total of 220 recreational runners were randomly assigned into the intervention and control groups. Both groups received pressure-sensitive insoles, but only the intervention group received real-time feedback on spatiotemporal metrics and relative speed. The feedback aimed to reduce loading on the joint/segment estimated to exhibit the highest load. Injury rates were compared between the groups using Cox regressions. Secondary outcomes compared included injury severity, the proportion of runners with multiple injuries, changes in self-reported personal best times and motivation (Behavioral Regulation in Exercise Questionnaire-2), and interest in continuing wearable use after study completion. Results: A total of 160 participants (73%) were included in analyses of the primary outcome. Intention-to-treat analysis showed no significant difference in injury rate between the groups (Hazard ratio [HR], 1.11; P = .70). This was expected, as 53 of 160 (33%) participants ended up in the unassigned group because they used incorrect wearable settings, nullifying any interventional effects. As-treated analysis showed a significantly lower injury rate among participants receiving real-time feedback (HR, 0.53; P = .03). Similarly, the first-time injury severity was significantly lower (-0.43; P = .042). Per-protocol analysis showed no significant differences in injury rates, but the direction favored the intervention group (HR, 0.67; P = .30). There were no significant differences in the proportion of patients with multiple injuries (HR, 0.82; P = .40) or changes in running performance (3.07%; P = .26) and motivation. Also, similar to 60% of the participants who completed the study showed interest in continuing wearable use. Conclusion: Real-time feedback on spatiotemporal metrics and relative speed provided by commercially available instrumented insoles may reduce the rate and severity of injuries in recreational runners. Feedback did not influence running performance and exercise motivation.
引用
收藏
页码:750 / 765
页数:16
相关论文
共 50 条
  • [21] Using Real Time Biofeedback to Alter Running Biomechanics: A Randomized Controlled Trial at the 6 Month Follow-up
    Morris, Jamie B.
    Goss, Donald L.
    Florkiewicz, Erin M.
    Davis, Irene S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 1079 - 1079
  • [22] Strip running deviation monitoring and feedback real-time in smart factories based on improved YOLOv5
    Luo, Jun
    Wang, Gang
    Zhou, Mingliang
    Pu, Huayan
    SUSTAINABLE COMPUTING-INFORMATICS & SYSTEMS, 2023, 40
  • [23] Impact of a wearable-based physical activity and sleep intervention in multimorbidity patients: protocol for a randomized controlled trial
    Neves, Bernardo
    Haghighi, Eduardo D.
    Pereira, Hugo V.
    Costa, Filipe
    Carlos, Joao S.
    Ferreira, Daniel
    Moreno, Plinio
    Ferreira, Pedro M.
    Machado, Jaime
    Goncalves, Breno
    Moreira, Jose Maria
    Leite, Francisca
    da Silva, Nuno Andre
    BMC GERIATRICS, 2023, 23 (01)
  • [24] Effect of an online educational module incorporating real-time feedback on accuracy of polyp sizing in trainees: a randomized controlled trial
    Mun, Elijah J.
    Yen, Timothy
    Hochheimer, Camille J.
    Tarter, Wyatt
    Kaltenbach, Tonya
    Keswani, Rajesh N.
    Wani, Sachin
    Patel, Swati G.
    ENDOSCOPY, 2024, 56 (06) : 421 - 430
  • [25] Impact of a wearable-based physical activity and sleep intervention in multimorbidity patients: protocol for a randomized controlled trial
    Bernardo Neves
    Eduardo D. Haghighi
    Hugo V. Pereira
    Filipe Costa
    João S. Carlos
    Daniel Ferreira
    Plinio Moreno
    Pedro M. Ferreira
    Jaime Machado
    Breno Goncalves
    José Maria Moreira
    Francisca Leite
    Nuno André da Silva
    BMC Geriatrics, 23
  • [26] Primary and secondary effects of real-time feedback to reduce vertical loading rate during running
    Baggaley, M.
    Willy, R. W.
    Meardon, S. A.
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2017, 27 (05) : 501 - 507
  • [27] Effects of a 12-Week Multifaceted Wearable-Based Program for People With Knee Osteoarthritis: Randomized Controlled Trial
    Li, Linda C.
    Feehan, Lynne M.
    Xie, Hui
    Lu, Na
    Shaw, Christopher D.
    Gromala, Diane
    Zhu, Siyi
    Avina-Zubieta, J. Antonio
    Hoens, Alison M.
    Koehn, Cheryl
    Tam, Johnathan
    Therrien, Stephanie
    Townsend, Anne F.
    Noonan, Gregory
    Backman, Catherine L.
    JMIR MHEALTH AND UHEALTH, 2020, 8 (07):
  • [28] REAL-TIME DIAGNOSTICS FOR ROS RUNNING SYSTEMS BASED ON PROBABILISTIC PATTERNS IDENTIFICATION
    Vechet, S.
    Krejsa, J.
    ENGINEERING MECHANICS 2019, 2019, 25 : 383 - 386
  • [29] Effects of Real-Time Feedback Methods on Static Balance Training in Stroke Patients: A Randomized Controlled Trial
    Kwon, Il-Ho
    Shin, Won-Seob
    Choi, Kyu-Seong
    Lee, Myung-Sun
    HEALTHCARE, 2024, 12 (07)
  • [30] THE EFFECT OF REAL-TIME CONTINUOUS GLUCOSE MONITORING IN DIABETIC PREGNANCY: A RANDOMIZED CONTROLLED TRIAL
    Secher, A. L.
    Ringholm, L.
    Andersen, H. U.
    Damm, P.
    Mathiesen, E. R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A21 - A22