Using convergent half width half Maximum(c-HWHM) tilting method to determine the virtual source position of scanning-pass scattering beam in carbon ion therapy

被引:0
|
作者
Zhang, Yi-He [1 ]
Ye, Yan-Cheng [1 ]
Zhang, Yan-Shan [1 ]
Wu, Jia-Ming [1 ,2 ,3 ]
机构
[1] Gansu Wuwei Tumor Hosp, Gansu Wuwei Acad Med Sci, Heavy Ion Ctr, Wuwei Canc Hosp, Wuwei City, Gansu Province, Peoples R China
[2] Chengde Med Univ, Dept Med Phys, Chengde City, Hebei Province, Peoples R China
[3] Yee Zen Gen Hosp, Dept Radiat Oncol, Tao Yuan City, Taiwan
关键词
Carbon ion beams; Virtual source position; Scanning-passive scatter beam; ACCURACY; EBT2;
D O I
10.1016/j.radphyschem.2023.111203
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Introduction: We developed a half-width half-maximum tilting angle convergent method to replace the conventional measurement of the virtual source position for scanning-pass scattering beam in carbon ion therapy.Materials and methods: A homemade large-format CMOS sensor and Gaf Chromic EBT3 films were used for the virtual source position measurement. The Gaf films were embedded in a self-designed rectangular plastic frame to tighten the films and set up on a treatment couch for irradiation in the air with the film perpendicular to the carbon ion beam at the nominal source-axis-distance (SAD) as well as upstream and downstream from the SAD. The radiation rectangular field size in horizontal and vertical directions on film or detector delivered by 5 carbon ion energies were analyzed separately in this study. The virtual source position was determined with film or detector at a distance upstream or downstream from the various source-film-distance by the half width half maximum tilting angle convergent method to compare the results conducted with the same measurement condition by the back projecting the FWHM to zero methods.Results: The determination of virtual source position by using half width half maximum tilting angle convergent method agrees with the method by back projecting the FWHM to zero, and for higher carbon ion energy has an obvious longer virtual source position since the more carbon ion beam energy, hence, the less side scatter results in the less divergent at the downstream, then the virtual source positions is distal for high energies than low energies when back projects the field sizes to zero.Conclusion: We have developed a technique capable of dealing with the virtual source position with a geometric convergent method to avoid any mistakes in the passive scatter carbon ion beam. The method for investigating the virtual source position in the carbon ion beam in this study can also be used for electrons and proton beams.
引用
收藏
页数:7
相关论文
共 7 条
  • [1] The determination of virtual source position using convergent arcSIN method for scanning-passive scatter beam in carbon ion therapy
    Chen, Hai-Shi
    Meng, Li
    Wu, Jia-Ming
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (04)
  • [2] The determination of virtual source position using convergent arcCOS method for scanning-passive scatter beam in carbon ion therapy
    Qi, Y.
    Zhang, Y-S.
    Ye, Y-C.
    Lee, T-F.
    Wu, J-M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (03): : 521 - 530
  • [3] The study of virtual source position with the geometric convergent ratio errors prevention management method of spot scanning beam in carbon ion therapy
    Zhang, Wen-Hua
    Luo, Bing-Zhi
    Ye, Yan-Cheng
    Wu, Jia-Ming
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (13) : 1367 - 1375
  • [4] Determination of virtual source position using back projecting zero and convergent arcTAN method for scanning-passive scatter beam in carbon ion therapy
    Meng, Wan-Bin
    Li, Qiang
    Ye, Yan-Cheng
    Wu, Jia-Ming
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (01) : 181 - 197
  • [5] The determination of virtual source position using convergent anti-trigonometric functions (arcCOS and arcSIN) method for scanning-passive scatter beam in carbon ion therapy
    Ye, Yan-Cheng
    Zhang, Wen-Hua
    Wang, Jian
    Zhang, Yan-Shan
    Wu, Jia-Ming
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 10 - 25
  • [6] The Determination of Virtual Source Position Using Poka-Yoke Concept to Minimize Mistakes for Scanning-Passive Scatter Beam in Carbon Ion Therapy
    Ye, Yan-Cheng
    Zhang, Yan-Shan
    Lee, Tsair-Fwu
    Wu, Jia-Ming
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2023, 66 (03) : 466 - 475
  • [7] The Determination of Virtual Source Position Using Poka-Yoke Concept to Minimize Mistakes for Scanning-Passive Scatter Beam in Carbon Ion Therapy
    Yan-Cheng Ye
    Yan-Shan Zhang
    Tsair-Fwu Lee
    Jia-Ming Wu
    Instruments and Experimental Techniques, 2023, 66 : 466 - 475