Determination of virtual source position using back projecting zero and convergent arcTAN method for scanning-passive scatter beam in carbon ion therapy

被引:0
|
作者
Meng, Wan-Bin [1 ,2 ]
Li, Qiang [1 ]
Ye, Yan-Cheng [3 ,4 ]
Wu, Jia-Ming [3 ,4 ,5 ,6 ]
机构
[1] Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
[2] Univ Chinese Acad Sci, Beijing, Peoples R China
[3] Wuwei Canc Hosp, Heavy Ion Ctr, Wuwei City, Gansu, Peoples R China
[4] Gansu Wuwei Acad Med Sci, Gansu Wuwei Tumor Hosp, Wuwei City, Gansu, Peoples R China
[5] Chengde Med Univ, Dept Med Phys, Chengde City, Hebei, Peoples R China
[6] Yee Zen Gen Hosp, Dept Radiat Oncol, Taoyuan, Taiwan
关键词
Carbon ion beams; virtual source position; scanning-passive scatter beam; RADIATION-THERAPY; ALGORITHMS; ACCURACY; EBT2;
D O I
10.3233/XST-221274
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
OBJECTIVE: This study aims to develop and test a newtechnique by using the convergent arcTAN(cATAN) method capable of dealing with the virtual source position delivered by different carbon ion energies from the pattern of scanning-passive scatter beam. MATERIALS AND METHODS: A homemade large-format CMOS sensor and Gaf Chromic EBT3 films are used for the virtual source position measurement. The Gaf films are embedded in a self-designed rectangular plastic frame to tighten films and set up on a treatment couch for irradiation in air with the film perpendicular to the carbon ion beam at the nominal source-axis-distance (SAD) as well as upstream and downstream from the SAD. The horizontal carbon ion beam with 5 energies at a machine opening field size is carried out in this study. The virtual source position is determined by using the convergent arcTAN (cATAN) method and compared with a linear regression by back projecting FWHM to zero at a distance upstream from the various source-film-distance. RESULTS: The film FWHM measurement error of 0.5mm leads to 0.001% deviation of alpha (cATAN) at every assumed textend. The overall uncertainty for the reproducibility of calculated virtual source position by the assumed textend in the vertical and horizontal directions amounts to 0.1%. The errors of calculated virtual source position by assumed textend with back projecting FWHM to zero methods are within 1.1 +/- 0.001, p = 0.033. CONCLUSION: We develop a new technique capable of dealing with the virtual source position with a convergent arcTAN method to avoid any manual measurement mistakes in scanning-passive scatter carbon ion beam. The readers are encouraged to conduct the proposed cATAN method in this study to investigate the virtual source position in the Linac-based external electron beams and the proton beams.
引用
收藏
页码:181 / 197
页数:17
相关论文
共 7 条
  • [1] The determination of virtual source position using convergent arcSIN method for scanning-passive scatter beam in carbon ion therapy
    Chen, Hai-Shi
    Meng, Li
    Wu, Jia-Ming
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (04)
  • [2] The determination of virtual source position using convergent arcCOS method for scanning-passive scatter beam in carbon ion therapy
    Qi, Y.
    Zhang, Y-S.
    Ye, Y-C.
    Lee, T-F.
    Wu, J-M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (03): : 521 - 530
  • [3] The determination of virtual source position using convergent anti-trigonometric functions (arcCOS and arcSIN) method for scanning-passive scatter beam in carbon ion therapy
    Ye, Yan-Cheng
    Zhang, Wen-Hua
    Wang, Jian
    Zhang, Yan-Shan
    Wu, Jia-Ming
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 10 - 25
  • [4] The Determination of Virtual Source Position Using Poka-Yoke Concept to Minimize Mistakes for Scanning-Passive Scatter Beam in Carbon Ion Therapy
    Ye, Yan-Cheng
    Zhang, Yan-Shan
    Lee, Tsair-Fwu
    Wu, Jia-Ming
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2023, 66 (03) : 466 - 475
  • [5] The Determination of Virtual Source Position Using Poka-Yoke Concept to Minimize Mistakes for Scanning-Passive Scatter Beam in Carbon Ion Therapy
    Yan-Cheng Ye
    Yan-Shan Zhang
    Tsair-Fwu Lee
    Jia-Ming Wu
    Instruments and Experimental Techniques, 2023, 66 : 466 - 475
  • [6] The study of virtual source position with the geometric convergent ratio errors prevention management method of spot scanning beam in carbon ion therapy
    Zhang, Wen-Hua
    Luo, Bing-Zhi
    Ye, Yan-Cheng
    Wu, Jia-Ming
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (13) : 1367 - 1375
  • [7] Using convergent half width half Maximum(c-HWHM) tilting method to determine the virtual source position of scanning-pass scattering beam in carbon ion therapy
    Zhang, Yi-He
    Ye, Yan-Cheng
    Zhang, Yan-Shan
    Wu, Jia-Ming
    RADIATION PHYSICS AND CHEMISTRY, 2023, 213