Optimization sizing of an autonomous photovoltaic-battery microgrid system

被引:2
|
作者
Amara, Sihem [1 ]
Toumi, Sana [1 ,2 ]
Ben Salah, Chokri [1 ,3 ]
Saidi, Abdelaziz Salah [4 ,5 ]
机构
[1] Univ Monastir, Natl Sch Engineers Monastir, Dept Elect Engn, Lab Automat Elect Syst & Environm LASEE, Monastir, Tunisia
[2] Univ Brest, UMR CNRS IRDL 6027, Brest, France
[3] Univ Sousse, Higher Inst Appl Sci & Technol Sousse ISSAT Souss, Sousse, Tunisia
[4] King Khalid Univ, Dept Elect Engn, Abha, Saudi Arabia
[5] Univ Tunis El Manar, Natl Sch Engineers Tunis, Lab Elect Syst, Tunis, Tunisia
关键词
Microgrid; photovoltaic; battery; optimal sizing; reliability; economic; relative excess power generated; deficiency of power supply probability; energy cost; total net present cost; PARTICLE SWARM OPTIMIZATION; TECHNOECONOMIC ANALYSIS; SIZE OPTIMIZATION; GRID SYSTEM; HYBRID; MANAGEMENT; METHODOLOGY; ALGORITHM; CELL;
D O I
10.1177/09596518221103039
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article describes a photovoltaic-battery microgrid system used for isolated sites. Indeed, a 50 kW photovoltaic panel is associated with a boost converter. To guarantee more reliable and economical energy supply, a battery storage system is included within the microgrid system. To determine the optimal sizing of the microgrid system, many approaches have been proposed. However, these approaches need a big database applied throughout a year, which can make the sizing more expensive and required a long computing time. In this article, a new approach is proposed, using real weather data (solar radiation and ambient temperature). It is based on two technical criteria; the deficiency of power supply probability and the relative excess power generated to study the system reliability and two economic criteria; the energy cost and the total net present cost to study the system cost. Compared to other approaches, sizing results applied for a year can be deduced using just the month when the microgrid system can work at the optimum conditions with optimal configuration (photovoltaic power and battery) achieving a minimal cost energy without deficiency of power supply probability, which make the sizing simpler and less expensive. The results obtained prove the effectiveness of the proposed approach in sizing problem. All results have been checked carrying out MATLAB simulations using real weather data.
引用
下载
收藏
页码:638 / 652
页数:15
相关论文
共 50 条
  • [21] Optimum Sizing of Photovoltaic-Battery Power Supply for Drone-Based Cellular Networks
    Javidsharifi, Mahshid
    Pourroshanfekr Arabani, Hamoun
    Kerekes, Tamas
    Sera, Dezso
    Spataru, Sergiu Viorel
    Guerrero, Josep M.
    DRONES, 2021, 5 (04)
  • [22] Coordinated power sharing among multiple subgrids in a photovoltaic-battery based DC microgrid
    Panda, Mrutunjaya
    Bhaskar, Devara Vijaya
    Maity, Tanmoy
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (02) : 5358 - 5380
  • [23] Distributed Incremental Adaptive Filter Controlled Residential Photovoltaic-Battery Microgrid for Rural Electrification
    Singh, Bhim
    Kumar, Shailendra
    2018 5TH IEEE UTTAR PRADESH SECTION INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS AND COMPUTER ENGINEERING (UPCON), 2018, : 1099 - 1104
  • [24] Adaptive Bandpass Digital Filter Control of Photovoltaic-Battery Energy Storage Based Microgrid
    Shubhra
    Singh, Bhim
    2018 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2018,
  • [25] A modified honey badger algorithm for optimal sizing of an AC coupled stand-alone photovoltaic-battery system
    Kamarzaman, Nur Atharah
    Sulaiman, Shahril Irwan
    Yassin, Ahmad Ihsan Mohd
    Zainuddin, Hedzlin
    Ibrahim, Intan Rahayu
    ENERGY REPORTS, 2022, 8 : 902 - 909
  • [26] Sizing Photovoltaic-Geothermal Smart Microgrid with Battery Storage Interface
    Lazar, Eniko
    Patarau, Toma
    Etz, Radu
    Petreus, Dorin
    2015 38TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY (ISSE 2015), 2015, : 364 - 369
  • [27] Structural Optimization and Thermal Management with PCM-Honeycomb Combination for Photovoltaic-Battery Integrated System
    Li, Xinxi
    Zhang, Jiangyun
    Zhou, Dequan
    Zhang, Guoqing
    Wu, Hongwei
    Liu, Rensheng
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2022, 2022
  • [28] An Isolated Standalone Photovoltaic-Battery System for Remote Areas Applications
    Carralero, Leandro L. O.
    Gomes, Hugo M. T. C.
    Costa, Fabiano F.
    Bahia, Filipe A. da C.
    Andrade, Antonio M. S. S.
    Pinheiro, Jose R.
    Tahim, Andre P. N.
    JOURNAL OF ENERGY STORAGE, 2022, 55
  • [29] Optimum Design of Diesel Generator Integrated Photovoltaic-Battery System
    Arun, P.
    Banerjee, Rangan
    Bandyopadhyay, Santanu
    ENERGY & FUELS, 2010, 24 (12) : 6565 - 6575
  • [30] A PLC controller algorithm for optimum operation of photovoltaic-battery system
    Al-Kandari, Ahmad
    Gilany, Mahmoud
    Shaltout, A.
    2006 LARGE ENGINEERING SYSTEMS CONFERENCE ON POWER ENGINEERING, 2006, : 112 - +