Structural capacity of a composite slim-floor beam with hollow steel tube shear connectors

被引:1
|
作者
Majdub, Mohamed S. [1 ,3 ]
Baharom, Shahrizan [1 ,2 ,4 ]
Al Zand, Ahmed W. [1 ,2 ]
Mutalib, Azrul A. [1 ,2 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Civil Engn, Bangi, Malaysia
[2] UKM, Smart & Sustainable Township Res Ctr SUTRA, Bangi, Malaysia
[3] Elmergib Univ, Dept Civil Engn, Al Khums, Libya
[4] Natl Univ Malaysia, Fac Engn & Built Environm, Dept Civil Engn, Ukm Bangi 43600, Malaysia
关键词
Composite slim-floor; shear connector; hollow steel tube connector; shear interaction; shear capacity; PUSH-OUT TEST; FLEXURAL BEHAVIOR; MECHANISMS; DESIGN;
D O I
10.1080/15397734.2024.2305777
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
A slim-floor composite beam's structural performance relies on the composite action provided by shear connectors. However, the information on the performance of composite slim-floor beam with HSTs connectors in flexural in term of moment capacity, shear interaction and ductility still needs to be clarified. Thus, six specimens of the composite beams with square and rectangular HSTs with two different beam sections, I and inverted T, were tested. The main failure was found to be concrete crushing in the area of the connectors. HST connectors prevented the concrete slab from uplifting, particularly in the specimens without a top flange. Subsequently, this increased moment capacity to 230% and 152% for inverted T and I-beam sections, respectively. Furthermore, ductility behavior was also improved and met EC4 requirements. The degree of shear interaction was increased from 0.4 up to 0.9 compared to the beam without HST. The predicted results from the suggested procedure to estimate moment capacity agreed well with the experimental results, with a maximum difference of 7% in the I-section specimen. In contrast, the predicted value for the inverted T specimen overestimates about 26%. Overall, the beam with the HST shear connector significantly improved the flexural performance of the composite slim floor beam.
引用
收藏
页码:7637 / 7669
页数:33
相关论文
共 50 条
  • [21] Simplified method for the determination of the influence of flexibility of shear connection on deflections of composite beams and slim-floor systems
    Hanswille, Gerhard
    Schaefer, Markus
    STAHLBAU, 2007, 76 (11) : 845 - 854
  • [22] BEAM-TO-COLUMN JOINTS FOR SLIM-FLOOR SYSTEMS IN SEISMIC ZONES
    Vulcu, C.
    Don, R.
    Ciutina, A.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1158 - 1169
  • [23] Numerical Study of the Fire Behavior of Encased and Slim-Floor Composite Beams
    Wang, Wenjun
    Jiang, Binhui
    Ding, Fa-xing
    Wang, Yong
    Liu, Xue-mei
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2023, 37 (06)
  • [24] Experimental investigation of Composite Slim-Floor Beams - Application of concrete dowels
    Braun, Matthias
    Hechler, Oliver
    Obiala, Renata
    Kuhlmann, Ulrike
    Eggert, Florian
    Hauf, Gunter
    Konrad, Matthias
    STAHLBAU, 2014, 83 (10) : 741 - 749
  • [25] A Detailed Numerical Model for a New Composite Slim-Floor Slab System
    Dudziak, Slawomir
    Lewinski, Pawel M.
    MATERIALS, 2024, 17 (07)
  • [26] Fire behavior and resistance of partially encased and slim-floor composite beams
    Ahn, Jae-Kwon
    Lee, Cheol-Ho
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 129 : 276 - 285
  • [27] The Effect of Steel Strength on the Behavior of a K-Joint in a Slim-floor Truss
    Saremi, Pooya
    Lu, Wei
    Puttonen, Jari
    Pada, Dan
    Kesti, Jyrki
    Puttonen, Jari (jari.puttonen@aalto.fi), 1600, John Wiley and Sons Inc (04): : 2 - 4
  • [28] Composite slim floor stainless steel beam construction exposed to different fires
    Ellobody, Ehab
    ENGINEERING STRUCTURES, 2012, 36 : 1 - 13
  • [29] Heat transfer analysis of concrete-filled steel tubular columns to slim-floor beam connections subjected to fire
    Romero, Manuel L.
    Albero, Vicente
    Espinös, Ana
    Hospitaler, Antonio
    Pascual, Ana M.
    ce/papers, 2017, 1 (5-6) : 311 - 316
  • [30] Influence of the RFS Geometry on the Performance of Dissipative Slim-Floor Beam-to-Column Joints
    Don, Rafaela
    Vulcu, Cristian
    Ciutina, Adrian
    Stratan, Aurel
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, STESSA 2024 - VOL 1, 2024, 519 : 373 - 385