Investigation on indoor airflow and contaminant dispersion of diffuse ceiling ventilation in heating and cooling modes

被引:8
|
作者
Peng, Pei [1 ]
Zhang, Chen [2 ]
Li, Wenqiang [3 ,4 ]
Pomianowski, Michal [2 ]
Gong, Guangcai [5 ]
Fang, Xi [5 ]
Chun, Liang [6 ]
Guo, Rui [7 ]
机构
[1] Wuhan Text Univ, Sch Environm Engn, Wuhan 430073, Peoples R China
[2] Aalborg Univ, Dept Built Environm, DK-9220 Aalborg, Denmark
[3] China Three Gorges Univ, Coll Civil Engn & Architecture, Yichang 443002, Peoples R China
[4] China Three Gorges Univ, Hubei Key Lab Disaster Prevent & Mitigat, Yichang 443002, Peoples R China
[5] Hunan Univ, Dept Civil Engn, Changsha 433200, Peoples R China
[6] Southwest Univ Sci & Technol, Coll Civil Engn & Architecture, Mianyang 621010, Peoples R China
[7] Katholieke Univ Leuven, Dept Civil Engn, Kasteelpark Arenberg 40, B-3001 Heverlee, Belgium
来源
关键词
Diffuse ceiling ventilation; Space heating and cooling; Thermal environment; Indoor air quality; MIXING VENTILATION; CFD ANALYSIS; PERFORMANCE; OFFICE; BUILDINGS; RADIATION; SYSTEMS;
D O I
10.1016/j.jobe.2023.107972
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper systematically investigates the indoor airflow and contaminant dispersion of diffuse ceiling ventilation (DCV) for space heating and cooling. A numerical model of the office with DCV is built and validated. The indoor thermal comfort and air quality (IAQ) under different cases are analyzed. Simultaneously, different indices are employed to determine the influence of exhaust positions and air change rates on the system. The results indicate that DCV can provide a satisfying thermal environment both in heating and cooling modes, and there is no reverse flow from the room to the plenum. Besides, the visualizations of indoor airflow, temperature distributions, and mean age of air (MAA) show the different characteristics during heating and cooling. The ranges of contaminant removal effectiveness (CRE) and temperature effectiveness (TE) are 0.87-1.00 and 0.79-1.55 for heating, respectively. For cooling, they are 0.96-1.23 (CRE) and 0.92-1.06 (TE), respectively. Although the TE for heating is slightly higher than that of cooling, the CO2 concentrations and CRE manifest that DCV performs better for space cooling. Moreover, the results show that the exhaust positions influence TE more than CRE, especially for heating. Within the measured air change rates, it is found that the increase of air change per hour (ACH) can aid to the ventilation effectiveness of DCV. Meanwhile, the linear regression equations between ACHs and MAA are obtained. This research is helpful to reveal the flow mechanisms of DCV and guides the design and operation of the system.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] An Overview of Natural Ventilation, Airflow, Evaporative Cooling and Heat Pump Heating in Greenhouses under Mild Climatic Conditions
    Ishii, M.
    Okushima, L.
    Moriyama, H.
    Sase, S.
    INTERNATIONAL SYMPOSIUM ON NEW TECHNOLOGIES FOR ENVIRONMENT CONTROL, ENERGY-SAVING AND CROP PRODUCTION IN GREENHOUSE AND PLANT FACTORY - GREENSYS 2013, 2014, 1037 : 493 - 500
  • [42] A review of integrated radiant heating/cooling with ventilation systems- Thermal comfort and indoor air quality
    Zhang, Chen
    Pomianowski, Michal
    Heiselberg, Per Kvols
    Yu, Tao
    ENERGY AND BUILDINGS, 2020, 223
  • [43] Relaxing and working from home: Associations between heating, ventilation and cooling system typologies and indoor soundscape evaluation
    Torresin, Simone
    Albatici, Rossano
    Aletta, Francesco
    Babich, Francesco
    Oberman, Tin
    Stawinoga, Agnieszka Elzbieta
    Kang, Jian
    Journal of Physics: Conference Series, 2021, 2069
  • [44] Effect of ventilation patterns on indoor thermal comfort and air-conditioning cooling and heating load using simulation
    Dian Sekartaji
    Yuji Ryu
    Didit Novianto
    City and Built Environment , 1 (1):
  • [45] Predicting indoor particle dispersion under dynamic ventilation modes with high-order Markov chain model
    Mei, Xiong
    Zeng, Chenni
    Gong, Guangcai
    BUILDING SIMULATION, 2022, 15 (07) : 1243 - 1258
  • [46] Dispersion of indoor air pollutants emitted at near-floor levels in rooms with floor heating and mixing ventilation
    Jurelionis, Andrius
    Stasiuliene, Laura
    Prasauskas, Tadas
    Martuzevicius, Dainius
    INDOOR AND BUILT ENVIRONMENT, 2018, 27 (02) : 205 - 218
  • [47] Predicting indoor particle dispersion under dynamic ventilation modes with high-order Markov chain model
    Xiong Mei
    Chenni Zeng
    Guangcai Gong
    Building Simulation, 2022, 15 : 1243 - 1258
  • [48] The similitude of indoor airflow in natural ventilation for a reduced-scale model: Investigation of nonisothermal flow fields by RANS simulation
    Jiang, Zitao
    Kobayashi, Tomohiro
    Yamanaka, Toshio
    Sandberg, Mats
    Yamasawa, Haruna
    Shohei, Miyazawa
    BUILDING AND ENVIRONMENT, 2024, 262
  • [49] Experimental investigation of indoor aerosol dispersion and accumulation in the context of COVID-19: Effects of masks and ventilation
    Shah, Yash
    Kurelek, John W.
    Peterson, Sean D.
    Yarusevych, Serhiy
    PHYSICS OF FLUIDS, 2021, 33 (07)
  • [50] Numerical investigation of wind-driven natural ventilation performance in a multi-storey hospital by coupling indoor and outdoor airflow
    Jin, Ruiqiu
    Hang, Jian
    Liu, Shanshan
    Wei, Jianjian
    Liu, Yang
    Xie, Jielan
    Sandberg, Mats
    INDOOR AND BUILT ENVIRONMENT, 2016, 25 (08) : 1226 - 1247