Fire resistance of steel reinforced reactive powder concrete columns

被引:3
|
作者
Wang, Yuzhuo [1 ,2 ]
Guo, Liwei [1 ]
Wang, Rui [3 ,4 ]
Xu, Tiangui [5 ]
机构
[1] Shandong Jianzhu Univ, Sch Civil Engn, Jinan 250101, Shandong, Peoples R China
[2] Shandong Jianzhu Univ, Key Lab Bldg Struct Retrofitting & Underground Spa, Minist Educ, Jinan 250101, Shandong, Peoples R China
[3] Shandong Acad Bldg Sci Co Ltd, Jinan 250031, Shandong, Peoples R China
[4] Shandong Luneng Intelligence Technol Co Ltd, Jinan, Shandong, Peoples R China
[5] Southeast Univ, Sch Civil Engn, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Jiulonghu Campus, Nanjing 211189, Peoples R China
基金
中国国家自然科学基金;
关键词
Steel Reinforced Reactive Powder Concrete; (SRRPC); Failure mechanism; Fire resistance; Finite element mode; Simplified calculation formula; HIGH-TEMPERATURE; PERFORMANCE; FIBERS;
D O I
10.1016/j.istruc.2023.105238
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel reinforced reactive powder concrete (SRRPC) columns have been widely used in structures due to their excellent mechanical properties. However, owing to inadequate experimental data and a lack of design basis for SRRPC columns at high temperatures, which limits the application and development of this structure in practical engineering. Five SRRPC columns with different loads were experimentally investigated at high temperatures. Additionally, 15 sets of specimens were analyzed by using numerical simulation method of thermo-mechanical coupling, and the rules of steel ratio, rebar ratio, and number of heating surfaces on the fire resistance of SRRPC columns were obtained. The test results revealed that the fire resistance decreased by 52.7% when the axial compression ratio increased from 0.2 to 0.6; The fire resistance increased by 17.79% when the steel ratio increased from 4.08% to 10.21%; The fire resistance increased by 3.24% when the rebar ratio increased from 0.83% to 2.76%; The fire resistance decreased by 28.95% when the number of heating surfaces increased from single-face heating to four-face heating. According to the variation rule of each parameter, the correlation degree of each parameter on the fire resistance was obtained, it concluded that the axial compression ratio had the highest correlation degree, followed by the number of heating surfaces, while the correlation degrees of steel ratio and rebar ratio were relatively small. A formula was proposed to predict the fire resistance of SRRPC columns, which can provide a reference for fire resistance evaluation, repair and reinforcement of SRRPC structures in fire.
引用
下载
收藏
页数:16
相关论文
共 50 条
  • [21] Fire Resistance of Eccentrically Loaded Reinforced Concrete Columns
    Shujaat Hussain Buch
    Umesh Kumar Sharma
    Fire Technology, 2019, 55 : 1517 - 1552
  • [22] Evaluation of fire resistance of rectangular steel columns filled with fibre-reinforced concrete
    Kodur, VKR
    Lie, TT
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1997, 24 (03) : 339 - 349
  • [23] Parametric analysis on fire resistance of Angle Steel Strengthened Reinforced Concrete (ASSRC) columns
    Zhou, L. R.
    Mao, X. Y.
    SUSTAINABLE BUILDINGS AND STRUCTURES, 2016, : 65 - 70
  • [24] Study on fire-resistance performance of reinforced concrete filled steel tubular columns
    Han, Jinsheng
    Dong, Yuli
    Xu, Zhaodong
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2009, 30 (SUPPL. 2): : 265 - 270
  • [25] Effect of fire insulation on fire resistance of hybrid-fiber reinforced reactive powder concrete beams
    Hou, Xiaomeng
    Ren, Pengfei
    Rong, Qin
    Zheng, Wenzhong
    Zhan, Yao
    COMPOSITE STRUCTURES, 2019, 209 : 219 - 232
  • [26] FIRE PERFORMANCE OF STEEL HOLLOW COLUMNS FILLED WITH CONCRETE, REINFORCED CONCRETE AND FIBER REINFORCED CONCRETE
    Pires, Tiago A. C.
    Rodrigues, Joao Paulo C.
    do Rego Silva, Jose Jeferson
    Correia, Antonio M.
    ICEM15: 15TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2012,
  • [27] NONLINEAR ANALYSIS OF STEEL CONCRETE COLUMNS FIRE RESISTANCE
    Kralik, J.
    Klabnik, M.
    Grmanova, A.
    ENGINEERING MECHANICS 2016, 2016, : 314 - 317
  • [28] Fire performance of axially restrained steel reinforced concrete columns
    Zheng C.
    Wang G.
    Li Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (08): : 154 - 161
  • [29] Experimental Research on Fire Resistance of Reactive Powder Concrete
    Peng, Gai-Fei
    Kang, Yi-Rong
    Huang, Yan-Zhu
    Liu, Xiao-Ping
    Chen, Qiang
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2012, 2012
  • [30] Study on the compression performance of steel reactive powder concrete columns
    Li, Hongbing
    Wu, Fangbo
    Bu, Liangtao
    Liu, Yong
    Yao, Jiang
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (10) : 2018 - 2029