Twelve-crystal prototype of Li2MoO4 scintillating bolometers for CUPID and CROSS experiments

被引:2
|
作者
Alfonso, K. [1 ]
Armatol, A. [2 ]
Augier, C. [3 ]
Avignone, F. T., III [4 ]
Azzolini, O. [5 ]
Balata, M. [6 ]
Bandac, I. C. [7 ]
Barabash, A. S. [8 ]
Bari, G. [9 ]
Barresi, A. [10 ,11 ]
Baudin, D. [2 ]
Bellini, F. [12 ,13 ]
Benato, G. [6 ]
Berest, V. [2 ]
Beretta, M. [14 ]
Bettelli, M. [15 ]
Biassoni, M. [10 ]
Billard, J. [3 ]
Boldrini, V. [9 ,15 ]
Branca, A. [10 ,11 ]
Brofferio, C. [10 ,11 ]
Bucci, C.
Calvo-Mozota, J. M. [16 ]
Camilleri, J. [1 ]
Campani, A. [17 ,18 ]
Capelli, C. [19 ]
Capelli, S. [10 ,11 ]
Cappelli, L.
Cardani, L.
Carniti, P. [10 ,11 ]
Casali, N.
Celi, E. [19 ,20 ]
Chang, C. [21 ]
Chiesa, D. [10 ,11 ]
Clemenza, M. [10 ]
Colantoni, I. [22 ]
Copello, S.
Craft, E. [23 ]
Cremonesi, O. [10 ]
Creswick, R. J.
Cruciani, A.
D'Addabbo, A.
D'Imperio, G.
Dabagov, S. [24 ]
Dafinei, I.
Danevich, F. A. [25 ,26 ]
De Jesus, M.
de Marcillac, P.
Dell'Oro, S. [10 ,11 ]
Di Domizio, S.
机构
[1] Virginia Polytech Inst & State Univ, Blacksburg, VA 24061 USA
[2] Univ Paris Saclay, CEA, IRFU, Saclay, France
[3] Univ Lyon, Univ Lyon 1, CNRS IN2P3, IP2I Lyon, Villeurbanne, France
[4] Univ South Carolina, Columbia, SC USA
[5] INFN Lab Nazl Legnaro, Legnaro, Italy
[6] INFN Lab Nazl Gran Sasso, Assergi, AQ, Italy
[7] Lab Subterraneo Canfranc, Canfranc Estacion, Spain
[8] Natl Res Ctr Kurchatov Inst, Kurchatov Complex Theoret & Expt Phys, Moscow, Russia
[9] INFN Sez Bologna, Bologna, Italy
[10] INFN Sez Milano Bicocca, Milan, Italy
[11] Univ Milano Bicocca, Milan, Italy
[12] INFN Sez Roma, Rome, Italy
[13] Sapienza Univ Rome, Rome, Italy
[14] Univ Calif Berkeley, Berkeley, CA USA
[15] CNR, Inst Microelect & Microsyst, Bologna, Italy
[16] Univ Int La Rioja, Escuela Super Ingn & Tecnol, Logrono, Spain
[17] INFN Sez Genova, Genoa, Italy
[18] Univ Genoa, Genoa, Italy
[19] Lawrence Berkeley Natl Lab, Berkeley, CA USA
[20] Gran Sasso Sci Inst, Laquila, Italy
[21] Argonne Natl Lab, Argonne, IL USA
[22] CNR Inst Nanotechnol, Rome, Italy
[23] Yale Univ, New Haven, CT USA
[24] INFN Lab Nazl Frascati, Frascati, Italy
[25] NASU, Inst Nucl Res, Kiev, Ukraine
[26] INFN Sez Roma Tor Vergata, Rome, Italy
[27] Univ Paris, CNRS, IN2P3, IJCLab, Orsay, France
[28] Northwestern Univ, Evanston, IL USA
[29] MIT, Cambridge, MA USA
[30] Fudan Univ, Shanghai, Peoples R China
[31] Boston Univ, Boston, MA USA
[32] Calif Polytech State Univ San Luis Obispo, San Luis Obispo, CA USA
[33] Shanghai Jiao Tong Univ, Shanghai, Peoples R China
[34] Univ Calif Los Angeles, Los Angeles, CA USA
[35] Drexel Univ, Philadelphia, PA USA
[36] Johns Hopkins Univ, Baltimore, MD USA
[37] Beijing Normal Univ, Beijing, Peoples R China
[38] Univ Zaragoza, Ctr Astroparticulas & Fis Altas Energias, Zaragoza, Spain
[39] ARAID Fdn Agencia Aragonesa Invest & Desarrollo, Zaragoza, Spain
[40] Univ Sci & Technol China, Hefei, Peoples R China
[41] Nikolaev Inst Inorgan Chem, Novosibirsk, Russia
[42] INFN Sez Padova, Padua, Italy
[43] Univ Grenoble Alpes, CNRS, Grenoble INP, SIMAP,Inst Engn Univ Grenoble Alpes, Grenoble, France
[44] Univ Bologna, Bologna, Italy
基金
欧盟地平线“2020”; 新加坡国家研究基金会; 欧洲研究理事会; 美国国家科学基金会;
关键词
Cryogenic detectors; Double-beta decay detectors; Particle identification methods; Scintillators; scintillation and light emission processes (solid; gas and liquid scintillators); DOUBLE-BETA-DECAY; RESPONSE STABILIZATION; DETECTORS; PERFORMANCE;
D O I
10.1088/1748-0221/18/06/P06018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, mu Bq/kg, level of the LMO crystals radioactive contamination by Th-228 and Ra-226.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] First test of Li2MoO4 crystal as a cryogenic scintillating bolometer
    Barinova, O. P.
    Danevich, F. A.
    Degoda, V. Ya.
    Kirsanova, S. V.
    Kudovbenko, V. M.
    Pirro, S.
    Tretyak, V. I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 613 (01): : 54 - 57
  • [2] Test of 116CdWO4 and Li2MoO4 scintillating bolometers in the CROSS underground facility with upgraded detector suspension
    Ahmine, A.
    Bandac, I. C.
    Barabash, A. S.
    Berest, V.
    Berge, L.
    Calvo-Mozota, J. M.
    Carniti, P.
    Chapellier, M.
    Dafinei, I.
    Danevich, F. A.
    Dixon, T.
    Dumoulin, L.
    Ferri, F.
    Giuliani, A.
    Gotti, C.
    Gras, P.
    Helis, D. L.
    Ianni, A.
    Imbert, L.
    Khalife, H.
    Kobychev, V. V.
    Konovalov, S. I.
    Loaiza, P.
    de Marcillac, P.
    Marnieros, S.
    Marrache-Kikuchi, C. A.
    Martinez, M.
    Nones, C.
    Olivieri, E.
    de Solorzano, A. Ortiz
    Peinaud, Y.
    Pessina, G.
    Poda, D. V.
    Redon, Th.
    Rosier, Ph.
    Scarpaci, J. A.
    Tretyak, V. I.
    Umatov, V. I.
    Velazquez, M.
    Zarytskyy, M. M.
    Zolotarova, A.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (12)
  • [3] 100Mo-enriched Li2MoO4 scintillating bolometers for 0ν2β decay search: from LUMINEU to CUPID-0/Mo projects
    Poda, D. V.
    WORKSHOP ON CALCULATION OF DOUBLE-BETA-DECAY MATRIX ELEMENTS (MEDEX'17), 2017, 1894
  • [4] Crystal structure of Li2MOO4
    Barinova, AV
    Rastsvetaeva, RK
    Nekrasov, YV
    Pushcharovskii, DY
    DOKLADY CHEMISTRY, 2001, 376 (1-3) : 16 - 19
  • [5] A neutrinoless double-beta-decay search based on ZnMoO4 and Li2MoO4 scintillating bolometers
    Giuliani, Andrea
    XXVII INTERNATIONAL CONFERENCE ON NEUTRINO PHYSICS AND ASTROPHYSICS (NEUTRINO2016), 2017, 888
  • [6] Crystal Structure of Li2MoO4
    A. V. Barinova
    R. K. Rastsvetaeva
    Yu. V. Nekrasov
    D. Yu. Pushcharovskii
    Doklady Chemistry, 2001, 376 : 16 - 19
  • [7] Development of a Li2MoO4 scintillating bolometer for low background physics
    Cardani, L.
    Casali, N.
    Nagorny, S.
    Pattavina, L.
    Piperno, G.
    Barinova, O. P.
    Beeman, J. W.
    Bellini, F.
    Danevich, F. A.
    Di Domizio, S.
    Gironi, L.
    Kirsanova, S. V.
    Orio, F.
    Pessina, G.
    Pirro, S.
    Rusconi, C.
    Tomei, C.
    Tretyak, V. I.
    Vignati, M.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [8] Intrinsic radiopurity of a Li2MoO4 crystal
    Barinova, O. P.
    Cappella, F.
    Cerulli, R.
    Danevich, F. A.
    Kirsanova, S. V.
    Kobychev, V. V.
    Laubenstein, M.
    Nagorny, S. S.
    Nozzoli, F.
    Tretyak, V. I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (03): : 573 - 575
  • [9] Synthesis of Li2MoO4 Powder with Aqueous Solution Method and Li2MoO4 Single Crystal Growth
    Xue Mingjun
    Chen Liang
    Xiong Wei
    Zhou Yao
    Li Ying
    Yuan Hui
    ACTA OPTICA SINICA, 2021, 41 (11)
  • [10] A CUPID Li2100MoO4 scintillating bolometer tested in the CROSS underground facility
    Armatol, A.
    Armengaud, E.
    Armstrong, W.
    Augier, C.
    Avignone, F. T., III
    Azzolini, O.
    Bandac, I. C.
    Barabash, A. S.
    Bari, G.
    Barresi, A.
    Baudin, D.
    Bellini, F.
    Benato, G.
    Beretta, M.
    Berge, L.
    Bourgeois, Ch
    Biassoni, M.
    Billard, J.
    Boldrini, V
    Branca, A.
    Brofferio, C.
    Bucci, C.
    Calvo-Mozota, J. M.
    Camilleri, J.
    Candela, A.
    Capelli, S.
    Cappelli, L.
    Cardani, L.
    Carniti, P.
    Casali, N.
    Cazes, A.
    Celi, E.
    Chang, C.
    Chapellier, M.
    Charrier, A.
    Chiesa, D.
    Clemenza, M.
    Colantoni, I
    Collamati, F.
    Copello, S.
    Cremonesi, O.
    Creswick, R. J.
    Cruciani, A.
    D'Addabbo, A.
    D'Imperio, G.
    Dafinei, I
    Danevich, F. A.
    de Combarieu, M.
    De Deo, M.
    De Jesus, M.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (02)