Automatic Segmentation and Mechanical Characterisation of the Intraluminal Thrombus and Arterial Wall of Abdominal Aortic Aneurysms Using Time Resolved 3D Ultrasound Images

被引:4
|
作者
Nievergeld, Arjet Helena Margaretha [1 ,2 ]
Maas, Esther Jorien [1 ,2 ]
de Ruijter, Joerik [1 ]
Fonken, Judith Helena Cornelia [1 ,2 ]
van Sambeekan, Marcus Rodolph Henricus Maria [1 ,2 ]
Lopata, Richard Godfried Paulus [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, POB 513, NL-5600 MB Eindhoven, Netherlands
[2] Catharina Hosp, Dept Vasc Surg, Eindhoven, Netherlands
关键词
Abdominal aortic ancurysms; Intraluminal thrombus; Mechanical characterisation Segmentation; Ultrasound; RUPTURE; DIAMETER; DISTENSIBILITY; SURVEILLANCE; STRESS; RISK;
D O I
10.1016/j.ejvs.2023.03.033
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study proposed a method for semi-automatic segmentation of abdominal aortic aneurysms (AAAs) and their intraluminal thrombus (ILT), based on time resolved 3D ultrasound (US), and validated results with computed tomography (CT). Mechanical properties of both wall and ILT were determined, and possible correlations with ILT size and blood pressure were investigated.Methods: A semi-automatic segmentation algorithm was developed combining a star-Kalman approach with a 3D snake algorithm. The segmented geometries of both lumen and inner vessel wall were validated with both manual US based segmentations and CT based segmentations. Finally, the lumen and vessel wall distensibility and ILT compressibility were estimated and correlated with ILT size and blood pressure.Results: For the vessel wall and lumen, the median Similarity Index (SI) was 92% (IQR 90, 94%) and 83% (IQR 75, 87%), respectively. The distensibility of the vessel wall could be determined in 37 of 40 cases and had a median value of 0.28 10(-5) Pa -1 (IQR 0.18, 0.51 x10(-5)). The median systolic to diastolic volume change of the ILT was determined successfully in 21 of 40 patients, and was -0.57% (IQR -1.1, 1.2%). The vessel and lumen distensibility showed a strong correlation with the systolic pressure (p < .010), rather than with the diastolic pressure. Lumen distensibility was strongly correlated with ILT thickness (p = .023). The performance of the semi-automatic segmentation algorithm was shown to be as good as the manual segmentations and highly dependent on the visibility of the ILT (limited contrast in seven patients and clutter in nine patients).Conclusion: This study has shown promising results for mechanical characterisation of the vessel, and ILT, including a correlation between distensibility, ILT size, and blood pressure. For future work, the inclusion rate needs to be increased by improving the image contrast with novel US techniques.
引用
收藏
页码:418 / 427
页数:10
相关论文
共 50 条
  • [41] MANUAL AND AUTOMATIC 3D SEGMENTATION OF THE PUBIC PART OF THE LEVATOR ANI MUSCLE IN ULTRASOUND IMAGES
    Van den Noort, F.
    Grob, A. T.
    Van Stralen, M.
    Slump, C. H.
    Van der Vaart, C.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2017, 28 : S149 - S150
  • [42] Carotid Artery Segmentation in 3D Ultrasound Images Using a Hybrid Framework
    Wang, Xiaotong
    Zhang, Yaonan
    PROCEEDING OF THE IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2012, : 698 - 703
  • [43] Automatic lumen and outer wall segmentation of the carotid artery using a deformable 3D model in MR angiography and vessel wall images
    Van 'T Klooster, R.
    De Koning, P. J. H.
    Dehnavi, R. Alizadeh
    Tamsma, J. T.
    De Roos, A.
    Reiber, J. H. C.
    Van der Geest, R. J.
    EUROPEAN HEART JOURNAL, 2010, 31 : 1026 - 1026
  • [44] Development and evaluation of a semi-automatic 3D segmentation technique of the carotid arteries from 3D ultrasound images
    Gill, JD
    Ladak, HM
    Steinman, DA
    Fenster, A
    MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 214 - 221
  • [45] Fully automatic detection and segmentation of abdominal aortic thrombus in post-operative CTA images using Deep Convolutional Neural Networks
    Lopez-Linares, Karen
    Aranjuelo, Nerea
    Kabongo, Luis
    Maclair, Gregory
    Lete, Nerea
    Ceresa, Mario
    Garcia-Familiar, Ainhoa
    Macia, Ivan
    Gonzalez Ballester, Miguel A.
    MEDICAL IMAGE ANALYSIS, 2018, 46 : 202 - 214
  • [46] Real-Time Parametric Curved Needle Segmentation in 3D Ultrasound Images
    Neshat, Hamid Reza Sadeghi
    Patel, Rajni V.
    2008 2ND IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB 2008), VOLS 1 AND 2, 2008, : 758 - 763
  • [47] Automatic 3D segmentation of the liver from abdominal CT images: a level-set approach
    Pan, SY
    Dawant, BM
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 128 - 138
  • [48] Ultrasound Detection of Heterogeneous Accumulated Strain Within 3D Printed Patient Specific Abdominal Aortic Aneurysms
    Mix, Doran
    Arabadjis, Isaac
    Atene, Lynn
    Stoner, Michael
    Richards, Michael
    JOURNAL OF VASCULAR SURGERY, 2016, 63 (06) : 65S - 66S
  • [49] Automated 3D ultrasound bridges the gap between novices and experts in diameter assessment of abdominal aortic aneurysms
    Svendsen, Natasha M.
    Eiberg, Jonas P.
    Rouet, Laurence
    Ghulam, Qasam M.
    Skovgaard, Lene T.
    Broda, Magdalena
    Zielinski, Alexander
    Yeung, Karin
    Lorenzen, Ulver S.
    INTERNATIONAL ANGIOLOGY, 2024,
  • [50] 3D Ultrasound Measurements Are Highly Sensitive to Monitor Formation and Progression of Abdominal Aortic Aneurysms in Mouse Models
    Ibrahim, Nahla
    Bleichert, Sonja
    Klopf, Johannes
    Kurzreiter, Gabriel
    Knoebl, Viktoria
    Hayden, Hubert
    Busch, Albert
    Stiglbauer-Tscholakoff, Alexander
    Eilenberg, Wolf
    Neumayer, Christoph
    Bailey, Marc A.
    Brostjan, Christine
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9