Determination of Cl and S in crude oil by ICP-OES after sample digestion by microwave-induced combustion in disposable vessels

被引:2
|
作者
Mandlate, Jaime S. [1 ,2 ,3 ]
Henn, Alessandra S. [1 ,4 ]
Mello, Paola A. [1 ]
Flores, Erico M. M. [1 ]
Barin, Juliano S. [5 ]
Duarte, Fabio A. [1 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, Rio Grande do S, Brazil
[2] Univ Eduardo Mondlane, Dept Quim, POB 252, Maputo, Mozambique
[3] Univ Eduardo Mondlane, Ctr Reg Excelencia Estudos Engn & Tecnol Petr & Ga, POB 252, Maputo, Mozambique
[4] Univ Tecnol Fed Parana, Dept Quim, BR-85884000 Medianeira, PR, Brazil
[5] Univ Fed Santa Maria, Dept Tecnol & Ciencia Alimentos, Grp 3i, BR-97105900 Santa Maria, Rio Grande do S, Brazil
关键词
MIC-DV; Sample preparation; Chlorine; Sulfur; Crude oil; OPTICAL-EMISSION SPECTROMETRY; ATOMIC-ABSORPTION-SPECTROMETRY; SULFUR DETERMINATION; PETROLEUM COKE; TRACE; FEASIBILITY; STRATEGIES; CHLORINE; VANADIUM; NICKEL;
D O I
10.1016/j.aca.2023.341536
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, fast and promising sample preparation method based on microwave-induced combustion in disposable vessels (MIC-DV) was developed for Cl and S determination in crude oil by inductively coupled plasma optical emission spectrometry (ICP-OES). The MIC-DV consists of a new approach of conventional microwave-induced combustion (MIC). For the combustion, crude oil was pipetted on a disk of filter paper and placed on a quartz holder, followed by the addition of igniter solution (40 & mu;L of 10 mol L-1 NH4NO3). The quartz holder was inserted into a commercial 50 mL disposable polypropylene vessel containing the absorbing solution, which was then inserted in an aluminium rotor. The combustion occurs under atmospheric pressure in a domestic microwave oven not compromising the operator's safety. The following parameters of combustion were evaluated: type, concentration and volume of absorbing solution, sample mass and the possibility of performing consecutive combustion cycles. Using MIC-DV, up to 10 mg of crude oil were efficiently digested, using 2.5 mL of ultrapure H2O as absorbing solution. Moreover, up to 5 consecutive combustion cycles were possible without analyte losses, reaching a total sample mass of 50 mg. The MIC-DV method was validated according to Eurachem Guide recommendations. Results obtained for Cl and S by MIC-DV were in agreement with those obtained using conventional MIC, as well as those obtained for S in a certified reference material of crude oil (NIST 2721). Analyte spike recovery experiments were performed and recoveries at three concentration levels ranged from 99 to 101% for Cl and from 95 to 97% for S, indicating a good accuracy. The limit of quantification achieved by ICP-OES after MIC-DV were 73 and 50 & mu;g g-1 for Cl and S respectively, applying 5 consecutive combustion cycles.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Determination of Major, Minor, and Toxic Elements in Tropical Fruits by ICP-OES After Different Microwave Acid Digestion Methods
    Ayca Karasakal
    Food Analytical Methods, 2021, 14 : 344 - 360
  • [42] Comparison of EDXRF and ICP-OES after microwave digestion for element determination in plant specimens from an abandoned mining area
    Marguí, E
    Queralt, I
    Carvalho, ML
    Hidalgo, M
    ANALYTICA CHIMICA ACTA, 2005, 549 (1-2) : 197 - 204
  • [43] Determination of Major, Minor, and Toxic Elements in Tropical Fruits by ICP-OES After Different Microwave Acid Digestion Methods
    Karasakal, Ayca
    FOOD ANALYTICAL METHODS, 2021, 14 (02) : 344 - 360
  • [44] Chloride determination by ion chromatography in petroleum coke after digestion by microwave-induced combustion
    Pereira, Juliana S. F.
    Diehl, Liange O.
    Duarte, Fabio A.
    Santos, Maria F. P.
    Guimaraes, Regina C. L.
    Dressler, Valderi L.
    Flores, Erico M. M.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (02) : 249 - 252
  • [45] Bromine, Chlorine, and Iodine Determination in Soybean and its Products by ICP-MS After Digestion Using Microwave-Induced Combustion
    Pereira Barbosa, Jose Tiago
    Moreira Santos, Clarissa Marques
    Bispo, Lilia dos Santos
    Lyra, Fernanda Henrique
    David, Jorge Mauricio
    Andrade Korn, Maria das Gracas
    Moraes Flores, Erico Marlon
    FOOD ANALYTICAL METHODS, 2013, 6 (04) : 1065 - 1070
  • [46] Bromine, Chlorine, and Iodine Determination in Soybean and its Products by ICP-MS After Digestion Using Microwave-Induced Combustion
    José Tiago Pereira Barbosa
    Clarissa Marques Moreira Santos
    Lilia dos Santos Bispo
    Fernanda Henrique Lyra
    Jorge Mauricio David
    Maria das Graças Andrade Korn
    Erico Marlon Moraes Flores
    Food Analytical Methods, 2013, 6 : 1065 - 1070
  • [47] Determination of halogens and sulfur in pitch from crude oil by plasma-based techniques after microwave-induced combustion
    Pereira, Leticia S. F.
    Frohlich, Angelica C.
    Duarte, Fabio A.
    Burrow, Robert A.
    Muller, Edson I.
    Flores, Erico M. M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (08) : 1822 - 1827
  • [48] Determination of Platinum in Waste Platinum-loaded Carbon Catalyst Samples Using Microwave-assisted Sample Digestion and ICP-OES
    Ma, Yinbiao
    Wei, Xiaojuan
    ADVANCES IN ENERGY SCIENCE AND ENVIRONMENT ENGINEERING, 2017, 1829
  • [49] Microwave-induced combustion for petroleum coke digestion: a promising sample preparation strategy for subsequent elemental determination
    Souza, J. P.
    Boff, J. L.
    Rodrigues, L. F.
    Moraes, D. P.
    Pereira, J. S. F.
    ANALYTICAL METHODS, 2022, 14 (12) : 1285 - 1290
  • [50] Determination of trace metals by ICP-OES in petroleum cokes using a novel microwave assisted digestion method
    Gazulla, Maria Fernanda
    Ventura, Maria Jesus
    Orduna, Onica
    Rodrigo, Marta
    Torres, Ana
    TALANTA OPEN, 2022, 6