Management of Unstable C1 Fractures Involving the Lateral Mass: Posterior C1-C2 Screw-Rod Fixation and Fusion

被引:0
|
作者
Zou, Xiaobao [1 ]
Yang, Haozhi [1 ]
Deng, Chenfu [1 ]
Chen, Junlin [1 ]
Ma, Rencai [1 ]
Ma, Xiangyang [1 ]
Xia, Hong [1 ]
机构
[1] Gen Hosp Southern Theatre Command Peoples Liberat, Dept Orthoped, Guangzhou, Guangdong, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2023年 / 29卷
基金
中国国家自然科学基金;
关键词
Atlas; Internal Fracture Fixation; Spinal Fractures; Spinal Fusion; ATLAS FRACTURES; JEFFERSON; OSTEOSYNTHESIS; REDUCTION; OUTCOMES; PLATE;
D O I
10.12659/MSM.938600
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Although most unstable C1 fractures can be effectively treated either by conservative treatment with external immobilization or by surgical procedure of C1-ring osteosynthesis, those fractures involving the lateral mass are likely to lead to traumatic arthritis and persistent neck pain. Specific reports of treatment of unstable C1 fractures involving the lateral mass are still scarce. We therefore present this report to evaluate the effectiveness of posterior C1-C2 screw-rod fixation and fusion for unstable C1 fractures involving the lateral mass. Material/Methods: From June 2009 to June 2016 in our hospital, 16 cases were diagnosed with C1 fractures involving the lateral mass and treated by posterior C1-C2 screw-rod fixation and fusion. The patients' clinical data were retrospectively analyzed. Preoperative and postoperative images were taken to evaluate cervical sequence, location of screws, and bone fusion. Neurological status and neck pain levels were evaluated clinically on follow-up. Results: All patients underwent surgery successfully. The mean follow-up duration was 15.3 +/- 4.9 months (range 9-24 months). All patients obtained satisfying clinical outcomes with good neck pain alleviation, appropriate screw placement, and reliable bone fusion. None of the patients developed vascular or neurological complications during the operation or follow-up. Conclusions: Posterior C1-C2 screw-rod fixation and fusion is an effective management for unstable C1 fractures involving the lateral mass. This operation can provide reliable stabilization and satisfactory bone fusion.
引用
收藏
页数:7
相关论文
共 50 条
  • [22] Anatomic Consideration of the C1 Laminar Arch for Lateral Mass Screw Fixation via C1 Lateral Lamina : A Landmark between the Lateral and Posterior Lamina of the C1
    Kim, Jung-Hwan
    Kwak, Dai-Soon
    Han, Seung-Ho
    Cho, Sung-Min
    You, Seung-Hoon
    Kim, Moon-Kyu
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2013, 54 (01) : 25 - 29
  • [23] Biomechanical Comparison of C1 Lateral Mass-C2 Short Pedicle Screw-C3 Lateral Mass Screw-Rod Construct Versus Goel-Harms Fixation for Atlantoaxial Instability
    Lu, Young
    Lee, Yu-Po
    Bhatia, Nitin N.
    Lee, Thay Q.
    SPINE, 2019, 44 (07) : E393 - E399
  • [24] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis
    Dickman, CA
    Sonntag, VKH
    NEUROSURGERY, 1998, 43 (02) : 275 - 280
  • [25] Virtual placement of posterior C1-C2 transarticular screw fixation
    Spangenberg, P
    Coenen, V
    Gilsbach, JM
    Rohde, V
    NEUROSURGICAL REVIEW, 2006, 29 (02) : 114 - 117
  • [26] Virtual placement of posterior C1-C2 transarticular screw fixation
    Peter Spangenberg
    Volker Coenen
    Joachim Michael Gilsbach
    Veit Rohde
    Neurosurgical Review, 2006, 29 : 114 - 117
  • [27] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis
    Kanat, A
    Aydin, Y
    NEUROSURGERY, 1999, 44 (03) : 687 - 688
  • [28] C1 Titanium Cables Combined with C2 Pedicle Screw-Rod Fixation for Atlantoaxial Instability Not Suitable for Placement of C1 Screws
    Zhang, Jie-Hong
    Zhang, Zhi-Jing
    Zhu, Ya
    Shi, Jian-Dong
    Li, Bin
    Lu, Yi-Sheng
    WORLD NEUROSURGERY, 2018, 120 : E453 - E456
  • [29] C1-C2 transarticular screw fixation for treatment of C1-C2 instability
    Coyne, TJ
    Fehlings, MG
    Martin, RJ
    JOURNAL OF CLINICAL NEUROSCIENCE, 1996, 3 (03) : 243 - 246
  • [30] Transarticular C1-C2 screw fixation.: Results of unstable odontoid fractures and pseudarthrosis in the elderly
    Kaminski, A.
    Gstrein, A.
    Muhr, G.
    Mueller, E. J.
    UNFALLCHIRURG, 2008, 111 (03): : 167 - 172