Ratiometric electrochemical lateral flow immunoassay for the detection of Streptococcus suis serotype 2

被引:11
|
作者
Kunpatee, Kanjana [1 ]
Khantasup, Kannika [2 ,3 ]
Komolpis, Kittinan [1 ,3 ]
Yakoh, Abdulhadee [1 ,3 ]
Nuanualsuwan, Suphachai [3 ,4 ]
Sain, Mohini M. [5 ]
Chaiyo, Sudkate [1 ,3 ]
机构
[1] Chulalongkorn Univ, Inst Biotechnol & Genet Engn, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Pharmaceut Sci, Dept Biochem & Microbiol, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Fac Vet Sci, Ctr Excellence Food & Water Risk Anal FAWRA, Bangkok 10330, Thailand
[4] Chulalongkorn Univ, Dept Vet Publ Hlth, Bangkok 10330, Thailand
[5] Univ Toronto, Ctr Biocompos & Biomat Proc, Dept Mech & Ind Engn, Toronto, ON M5S 3B3, Canada
来源
关键词
Ratiometric; Electrochemical biosensor; Lateral flow immunoassay; Redox modification; Reproducibility; Streptococcus suis serotype 2; LABEL-FREE; SENSITIVE DETECTION; BIOSENSOR; IDENTIFICATION; IMMUNOSENSOR; POLYDOPAMINE; BACTERIA; SENSORS; PROTEIN; DESIGN;
D O I
10.1016/j.bios.2023.115742
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An electrochemical lateral flow immunoassay (eLFIA) strip with high reproducibility was developed to rapidly and accurately detect Streptococcus suis serotype 2. This proposed strip was fabricated by integrating ratiometric electrochemical detection and LFIA (R-eLFIA). The R-eLFIA exhibited excellent reproducibility, which was improved by 3.8 times compared to a single electrode. A dual-working screen-printed graphene electrode (SPGE) was designed by tuning the working electrode with electroactive species in the biosensing system. Ferrocene carboxylic acid (Fc) was used as a signal probe, and sunset yellow (SY) at one working electrode was used as an internal reference signal to provide a built-in correction for reducing the effects of inherent background current. S. suis serotype 2-specific antibodies were immobilized on a nitrocellulose membrane of LFIA, which is located on the position of Fc-SPGE. In the presence of the analyte, an immunocomplex formed on the region of Fc-SPGE, causing a decrease in Fc current while SY current remained constant. The current ratio's decrease was propor-tional to S. suis serotype 2's concentration. Under optimization, this biosensor showed good linearity in the range of 102-1010 CFU/mL with a limit of detection of 10 CFU/mL and achieved a rapid detection time (15 min). Moreover, the R-eLFIA biosensor exhibited excellent reproducibility and high selectivity and was applied in human serum samples. Thus, this study successfully matched the advantages of the ratiometric strategy and LFIA and has great potential to be used as an effective tool for rapidly detecting S. suis serotype 2 in clinical samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Response regulator important in pathogenesis of Streptococcus suis serotype 2
    de Greeff, A
    Buys, H
    van Alphen, L
    Smith, HE
    MICROBIAL PATHOGENESIS, 2002, 33 (04) : 185 - 192
  • [22] Human infective endocarditis caused by Streptococcus suis serotype 2
    Heidt, MC
    Mohamed, W
    Hain, T
    Vogt, PR
    Chakraborty, T
    Domann, E
    JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (09) : 4898 - 4901
  • [23] Streptococcus suis serotype 2 mutants deficient in capsular expression
    Charland, N
    Harel, J
    Kobisch, M
    Lacasse, S
    Gottschalk, M
    MICROBIOLOGY-SGM, 1998, 144 : 325 - 332
  • [24] Virulent strains of Streptococcus suis serotype 2 and highly virulent strains of Streptococcus suis serotype 1 can be recognized by a unique ribotype profile
    Smith, HE
    Rijnsburger, M
    StockhofeZurwieden, N
    Wisselink, HJ
    Vecht, U
    Smits, MA
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (05) : 1049 - 1053
  • [25] Expression and Characterization of Serotype 2 Streptococcus suis Arginine Deiminase
    Maneerat, Krissana
    Yongkiettrakul, Suganya
    Jiemsup, Surasak
    Tongtawe, Pongsri
    Gottschalk, Marcelo
    Srimanote, Potjanee
    JOURNAL OF MOLECULAR MICROBIOLOGY AND BIOTECHNOLOGY, 2017, 27 (03) : 133 - 146
  • [26] The CodY regulator is essential for virulence in Streptococcus suis serotype 2
    Liping Feng
    Jiawen Zhu
    Haitao Chang
    Xiaoping Gao
    Cheng Gao
    Xiaofeng Wei
    Fangyan Yuan
    Weicheng Bei
    Scientific Reports, 6
  • [27] Description of an albumin binding activity for Streptococcus suis serotype 2
    Quessy, S
    Busque, P
    Higgins, R
    Jacques, M
    Dubreuil, JD
    FEMS MICROBIOLOGY LETTERS, 1997, 147 (02) : 245 - 250
  • [28] Streptococcus suis serotype 2 binding to extracellular matrix proteins
    Esgleas, M
    Lacouture, S
    Gottschalk, M
    FEMS MICROBIOLOGY LETTERS, 2005, 244 (01) : 33 - 40
  • [29] Detection of Autoinducer-2 and Analysis of the Profile of luxS and pfs Transcription in Streptococcus suis Serotype 2
    Han, X. G.
    Lu, C. P.
    CURRENT MICROBIOLOGY, 2009, 58 (02) : 146 - 152
  • [30] Identification and Detection of Serotype-Specific Genes: Effective Serotyping of Streptococcus suis
    Wang K.
    Wu Z.
    Yao H.
    Qiu Y.
    Lu C.
    Current Clinical Microbiology Reports, 2017, 4 (1) : 29 - 35