A dual-labeled fluorescence quenching lateral flow assay based on one-pot enzyme-free isothermal cascade amplification for the rapid and sensitive detection of pathogens

被引:6
|
作者
Jiang, Hao [1 ]
Lv, Xuefei [1 ]
Li, Anyi [1 ]
Peng, Zhao [1 ]
Deng, Yulin [1 ]
Li, Xiaoqiong [1 ]
机构
[1] Beijing Inst Technol, Sch Life Sci, Beijing Key Lab Separat & Anal Biomed & Pharmaceut, Beijing 100081, Peoples R China
关键词
SIGNAL AMPLIFICATION; GOLD NANOPARTICLES; DNA; CIRCUITS; SENSOR; MICRO;
D O I
10.1039/d3ay00526g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid detection of nucleic acids is integral for clinical diagnostics, especially if a major public-health emergency occurs. However, such detection cannot be carried out efficiently in remote areas limited by medical resources. Herein, a dual-labeled fluorescence resonance energy transfer (FRET) lateral flow assay (LFA) based on one-pot enzyme-free cascade amplification was developed for rapid, convenient, and sensitive detection of open reading frame (ORF)1ab of severe acute respiratory syndrome-coronavirus-2. The catalyzed hairpin assembly (CHA) reaction of two well-designed hairpin probes was initiated by a target sequence and generated a hybridization chain reaction (HCR) initiator. Then, HCR probes modified with biotin were initiated to produce long DNA nanowires. After two-level amplification, the cascade-amplified product was detected by dual-labeled lateral flow strips. Gold nanoparticles (AuNPs)-streptavidin combined with the product and then ran along a nitrocellulose membrane under the action of capillary force. After binding with fluorescent microsphere-labeled-specific probes on the T line, a positive signal (red color) could be observed. Meanwhile, AuNPs could quench the fluorescence of the T line, and an inverse relationship between fluorescence intensity and the concentration of the CHA-HCR-amplified product was formed. The proposed strategy achieved a satisfactory limit of detection of 2.46 pM for colorimetric detection and 174 fM for fluorescent detection, respectively. Benefitting from the features of being one-pot, enzyme-free, low background, high sensitivity, and selectivity, this strategy shows great potential in bioanalysis and clinical diagnostics upon further development.
引用
收藏
页码:2641 / 2649
页数:9
相关论文
共 50 条
  • [41] Dual-Labeled PCR-Based Immunofluorescent Assay for the Rapid and Sensitive Detection of Enterotoxic Staphylococcus aureus Using Cocktail-Sized Liposomal Nanovesicles as Signal Enhancer
    Hsin-Yi Yin
    Hsiao-Wei Wen
    Food Analytical Methods, 2017, 10 : 3264 - 3274
  • [42] Dual-Labeled PCR-Based Immunofluorescent Assay for the Rapid and Sensitive Detection of Enterotoxic Staphylococcus aureus Using Cocktail-Sized Liposomal Nanovesicles as Signal Enhancer
    Yin, Hsin-Yi
    Wen, Hsiao-Wei
    FOOD ANALYTICAL METHODS, 2017, 10 (10) : 3264 - 3274
  • [43] Label-free molecular beacon-based quadratic isothermal exponential amplification: a simple and sensitive one-pot method to detect DNA methyltransferase activity
    Xue, Qingwang
    Wang, Lei
    Jiang, Wei
    CHEMICAL COMMUNICATIONS, 2015, 51 (70) : 13538 - 13541
  • [44] Sensitive lateral flow assay for bisulfite-free DNA methylation detection based on the restriction endonuclease GlaI and rolling circle amplification
    Dong, Ningning
    Wang, Wenjia
    Qin, Yanru
    Wang, Yang
    Shan, Hongbo
    ANALYTICA CHIMICA ACTA, 2022, 1227
  • [45] Visual Detection of Canine Parvovirus Based on Loop-Mediated Isothermal Amplification Combined with Enzyme-Linked Immunosorbent Assay and with Lateral Flow Dipstick
    Sun, Yu-Ling
    Yen, Chon-Ho
    Tu, Ching-Fu
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2014, 76 (04): : 509 - 516
  • [46] An enzyme-free and label-free fluorescence biosensor for microRNA detection based on cascade amplification of DNAzyme-powered three-dimensional DNA walker and hybridization chain reaction
    Wang, Rui
    Wang, Lei
    Xu, Xiaowen
    Jiang, Wei
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 268 : 287 - 292
  • [47] Sensitive, enzyme-free and label-free electrochemical sensor for K-ras G12D point mutation detection based on double cascade amplification reaction
    Zhou, Xiaomei
    Liu, Xiaoyu
    Xia, Xinyu
    Yang, Xiaoyan
    Xiang, Hua
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 870
  • [48] Rapid and equipment-free detection of Phytophthora capsici using lateral flow strip-based recombinase polymerase amplification assay
    Yu, J.
    Shen, D.
    Dai, T.
    Lu, X.
    Xu, H.
    Dou, D.
    LETTERS IN APPLIED MICROBIOLOGY, 2019, 69 (01) : 64 - 70
  • [49] Multiplex fluorescence loop-mediated isothermal amplification with lateral flow assay for rapid simultaneous detection of mecA and nuc genes in methicillin-resistant Staphylococcus aureus
    Lee, Jeong-Eun
    Chang, Ji Yoon
    Shim, Won-Bo
    ANALYTICA CHIMICA ACTA, 2024, 1319
  • [50] Development of a recombinase polymerase based isothermal amplification combined with lateral flow assay (HLB-RPA-LFA) for rapid detection of "Candidatus Liberibacter asiaticus"
    Ghosh, Dilip Kumar
    Kokane, Sunil B.
    Kokane, Amol D.
    Warghane, Ashish J.
    Motghare, Manali R.
    Bhose, Sumit
    Sharma, Ashwani Kumar
    Reddy, M. Krishna
    PLOS ONE, 2018, 13 (12):