Characterization of Liquid Scintillator-Based CNES for Deuterium-Deuterium Neutron Emission Spectroscopy in the LHD

被引:1
|
作者
Sangaroon, Siriyaporn [1 ]
Ogawa, Kunihiro [2 ,3 ]
Isobe, Mitsutaka [2 ,3 ]
Liao, Longyong [4 ]
Kobayashi, Makoto Inami [2 ,3 ]
Zhong, Guoqiang [5 ]
Toyama, Sho [6 ]
Miwa, Misako [6 ]
Matsuyama, Shigeo [6 ]
Takada, Eiji [7 ]
Wisitsorasak, Apiwat [8 ]
Poolyarat, Nopporn [9 ]
Osakabe, Masaki [2 ,3 ]
机构
[1] Mahasarakham Univ, Fac Sci, Dept Phys, Maha Sarakham 44150, Thailand
[2] Natl Inst Fus Sci, Toki 5095202, Japan
[3] Grad Univ Adv Studies, SOKENDAI, Dept Res, Hayama 5095202, Japan
[4] Grad Univ Adv Studies, SOKENDAI, Hayama 5095202, Japan
[5] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
[6] Tohoku Univ, Grad Sch Engn, Sendai 9808576, Japan
[7] Natl Inst Informat, Tokyo 1018430, Japan
[8] Univ Technol Thonburi, Fac Sci, Dept Phys, Bangkok 10140, Thailand
[9] Thailand Inst Nucl Technol, Bangkok 10900, Thailand
关键词
Compact neutron emission spectrometer (CNES); Doppler effect; Large Helical Device (LHD); liquid scintillation detector; neutral beam (NB) injection; CALIBRATION;
D O I
10.1109/TIM.2023.3324350
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The compact neutron emission spectrometers (CNESs) based on conventional liquid (EJ-301) scintillation detectors were characterized in this work. The CNESs were employed for deuterium-deuterium neutron emission spectroscopy in the Large Helical Device (LHD). Prior to the installation, the EJ-301 scintillation detectors were characterized at the Fast Neutron Laboratory (FNL) of Tohoku University. In order to discriminate the neutron and gamma -ray signals, the charge comparison method was used. The neutron energy spectrum was successfully unfolded from the measured recoil proton energy spectrum of the EJ-301 scintillation detector using the derivative unfolding technique. The detector's energy resolution was examined. In the LHD, EJ-301-based CNESs with both tangential and perpendicular line-of-sight were employed for characterization. Furthermore, the characterization of the CNES was performed in the deuterium-deuterium experiment campaign. The operational capabilities of CNESs in the LHD were examined. Deuterium-deuterium neutron emission spectroscopy in various approaches of neutral beam (NB)-heated plasmas was conducted using CNES. Because of the high energy of the injected fast ions from tangential NB injection, an investigation of the Doppler effect on deuterium-deuterium neutron energy was conducted. The upper and lower shifted deuterium-deuterium neutron energies were observed when the fast ions moved toward and away from the tangential CNES, respectively. As expected, no notable energy shift was observed from fast ions injected by the perpendicular NB injection. Additionally, the 5-D orbit following code DELTA5D, which takes into account Larmor motion effects and the detector's energy resolution, was utilized to compute the expected deuterium-deuterium neutron energy spectrum that would be measured by the CNES. There was a concurrence between the calculations and experimental results.
引用
收藏
页数:10
相关论文
共 34 条
  • [1] Scaling formulas for deuterium-deuterium neutron emission in jet
    Karlsson, J
    Elevant, T
    FUSION TECHNOLOGY, 1998, 33 (03): : 341 - 349
  • [2] Characterization of a deuterium-deuterium plasma fusion neutron generator
    Lang, R. F.
    Pienaar, J.
    Hogenbirk, E.
    Masson, D.
    Nolte, R.
    Zimbal, A.
    Roettger, S.
    Benabderrahmane, M. L.
    Bruno, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 879 : 31 - 38
  • [3] Design and optimization of thermal neutron device based on deuterium-deuterium neutron generator
    He, De-Dong
    Jing, Shi-Wei
    Zheng, Yu-Lai
    FUSION ENGINEERING AND DESIGN, 2021, 166
  • [4] A DOSIMETRY STUDY OF DEUTERIUM-DEUTERIUM NEUTRON GENERATOR-BASED IN VIVO NEUTRON ACTIVATION ANALYSIS
    Sowers, Daniel
    Liu, Yingzi
    Mostafaei, Farshad
    Blake, Scott
    Nie, Linda H.
    HEALTH PHYSICS, 2015, 109 (06): : 566 - 572
  • [5] Liquid Scintillator-Based Neutron Detector Development
    Lavietes, Anthony
    Plenteda, Romano
    Mascarenhas, Nicholas
    Cronholm, L. Marie
    Aspinall, Michael
    Joyce, Malcolm
    Tomanin, Alice
    Peerani, Paolo
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 230 - 244
  • [6] Initial Results of Neutron Emission Profile Measurements in LHD Deuterium Plasmas
    Kawase, Hiroki
    Ogawa, Kunihiro
    Nishitani, Takeo
    Pu, Neng
    Murakami, Sadayoshi
    Isobe, Mitsutaka
    PLASMA AND FUSION RESEARCH, 2018, 13
  • [7] Design, testing and optimization of a neutron radiography system based on a Deuterium-Deuterium (D-D) neutron generator
    Bergaoui, K.
    Reguigui, N.
    Gary, C. K.
    Cremer, J. T.
    Vainionpaa, J. H.
    Piestrup, M. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 299 (01) : 41 - 51
  • [8] A feasibility study of a deuterium-deuterium neutron generator-based boron neutron capture therapy system for treatment of brain tumors
    Hsieh, Mindy
    Liu, Yingzi
    Mostafaei, Farshad
    Poulson, Jean M.
    Nie, Linda H.
    MEDICAL PHYSICS, 2017, 44 (02) : 637 - 643
  • [9] Regression Approach for Acquiring a Quantitative Guidance toward Updating the Deuterium-Deuterium Fusion Neutron Emission Rate in the Large Helical Device
    Ogawa, Kunihiro
    Yokoyama, Masayuki
    Isobe, Mitsutaka
    PLASMA AND FUSION RESEARCH, 2020, 15
  • [10] Regression Approach for Acquiring a Quantitative Guidance toward Updating the Deuterium-Deuterium Fusion Neutron Emission Rate in the Large Helical Device
    Ogawa K.
    Yokoyama M.
    Isobe M.
    Plasma and Fusion Research, 2020, 15 : 1202087 - 1