Microleakage and Marginal Integrity of Surface-Coated and Laser-Pretreated Class V Composite Restorations in Primary Teeth

被引:0
|
作者
Azimi, Niloofar [1 ]
Mohammadi, Najmeh [2 ]
Parsaie, Zahra [1 ]
Fereidouni, Kiarash [1 ]
机构
[1] Shiraz Univ Med Sci, Shiraz Dent Sch, Dept Pediat Dent, Shiraz, Iran
[2] Shiraz Univ Med Sci, Oral & Dent Dis Res Ctr, Shiraz Dent Sch, Shiraz, Iran
关键词
Laser; Leakage; Primary teeth; Resin composite; Surface coating; ER-YAG LASER; RESIN COMPOSITE; BOND STRENGTH; FISSURE SEALANT; ADHESIVE; IRRADIATION; INTERFACE; DENTIN; SEM; PIT;
D O I
10.34172/jlms.2023.11
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Despite the advanced formulations of resin composites, microleakage is still among the commonest causes of clinical failure of these restorations. We evaluated the effect of surface coating and laser pretreatment on the microleakage of Class V resin composite restorations in primary teeth. Methods: Sixty extracted primary molar teeth having intact lingual or facial surfaces were randomly allocated into the control, G-Coat Plus surface coating, and erbium-doped yttrium aluminum garnet (Er:YAG) laser pretreatment groups. Class V cavities were provided with the coronal and gingival margins in the dentin and enamel, respectively. Restoration of the cavities was done with Z250 resin composite and they were thermocycled, followed by immersing in 2% basic Fuchsin dye for 24 hrs. Samples underwent sectioning occlusogingivally and the microleakage was assessed under a stereomicroscope (40 x ). Statistical analysis was done via SPSS and Kruskal-Wallis test (alpha= 0.05). Results: The control and G-Coat plus groups were significantly different regarding the microleakage (P < 0.001), and G-Coat Plus and laser pretreatment groups (P < 0.001) at both gingival and occlusal margins. However, it showed no significant difference between the laser and the control group on the enamel (P = 0.063) and dentin margins (P = 0.757). Microleakage at the gingival margins was significantly greater compared to the occlusal margins in the control and laser groups (P< 0.001), but not in the G-Coat Plus group (P= 0.051). Conclusion: G-Coat plus coating significantly reduced microleakage at dentin and enamel margins of Class V composite restorations in primary teeth, in comparison with other groups of the study. Also, dentin margins showed more significant amounts of microleakage versus enamel margins in all groups, except for the G-Coat Plus group.
引用
收藏
页数:7
相关论文
共 47 条
  • [21] Microleakage in Class V composite resin restorations prepared conventionally and prepared with the Er:YAG laser
    Ramos, A
    Eduardo, CP
    Tanji, E
    Zenzell, D
    INTERNATIONAL LASER CONGRESS: LASERS AT THE DAWN OF THE THIRD MILLENNIUM, 1996, : 257 - 261
  • [22] Effects of different types of adhesive systems on the microleakage of compomer restorations in Class V cavities prepared by Er,Cr:YSGG laser in primary teeth
    Baygin, Ozgul
    Korkmaz, Fatih Mehmet
    Arslan, Ipek
    DENTAL MATERIALS JOURNAL, 2012, 31 (02) : 206 - 214
  • [23] Effect of three surface sealants on marginal sealing of Class V composite resin restorations
    Ramos, RP
    Chimello, DT
    Chinelatti, MA
    Dibb, RGP
    Mondelli, J
    OPERATIVE DENTISTRY, 2000, 25 (05) : 448 - 453
  • [24] Assessing microleakage of class V resin composite restorations after Er:YAG laser and bur preparation
    Aranha, ACC
    Turbino, ML
    Powell, GL
    Eduardo, CD
    LASERS IN SURGERY AND MEDICINE, 2005, 37 (02) : 172 - 177
  • [25] Influence of Erbium:YAG laser energies on the microleakage of Class V resin-based composite restorations
    Roebuck, EM
    Saunders, WP
    Whitters, CJ
    AMERICAN JOURNAL OF DENTISTRY, 2000, 13 (05): : 280 - 284
  • [26] Microleakage in class V composite resin restorations treated with CO2 laser -: an in vitro study
    da Cruz, ANL
    Netto, NG
    Pagliari, AF
    Matson, J
    Navarro, RS
    Zezell, DM
    Eduardo, CP
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1005 - 1005
  • [27] Effect of new generation surface sealants on the marginal permeability of class V resin composite restorations
    Owens, B. M.
    Johnson, W. W.
    OPERATIVE DENTISTRY, 2006, 31 (04) : 481 - 488
  • [28] Comparison of Microleakage of Three Adhesive Systems in Class V Composite Restorations Prepared with Er,Cr:YSGG Laser
    Kimyai, Soodabeh
    Ajami, Amir Ahmad
    Chaharom, Mohammad Esmaeel Ebrahimi
    Oskoee, Jafar Sadjadi
    PHOTOMEDICINE AND LASER SURGERY, 2010, 28 (04) : 505 - 510
  • [29] OCT Evaluation of Marginal and Internal Interface Integrity of Class V Composite Restorations after 36 to 48 Months
    Haak, Rainer
    Schaefer, Philip
    Hanssen, Bettina
    Ziebolz, Dirk
    Park, Kyung Jin
    Haefer, Matthias
    Schmalz, Gerhard
    Schneider, Hartmut
    JOURNAL OF ADHESIVE DENTISTRY, 2022, 24 (01): : 165 - 173
  • [30] Microleakage in Class V composite resin restorations treated with CO2 laser -: an in vitro study.
    da Cruz, ANL
    Netto, NG
    Pagliari, AF
    Matson, J
    Navarro, RS
    Eduardo, CD
    Zezell, DM
    LASERS IN DENTISTRY VI, 2000, 1 : 128 - 133