Experimental Study on Fire Resistance Performance of Concrete-Filled Steel Plate Composite Walls

被引:1
|
作者
Zhou, Ting [1 ]
Liu, Xueshan [1 ]
Liu, Hongbo [2 ]
Li, Yixuan [1 ]
Zhang, Pengfei [3 ]
Chen, Huazhou [3 ]
Chen, Zhihua [1 ]
机构
[1] Tianjin Univ, Tianjin 300072, Peoples R China
[2] Hebei Univ Engn, Handan 056000, Peoples R China
[3] China Construct Sci & Ind Corp LTD, Beijing 100089, Peoples R China
关键词
Concrete-filled steel plate composite walls; Fire resistance; Fire protection measures; Autoclaved lightweight concrete plate; Fire-retardant coating; BEHAVIOR; ROBUSTNESS; SYSTEM;
D O I
10.1007/s13296-022-00700-4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled steel plate composite walls are increasingly used in high-rise buildings; their mechanical properties at room temperature have produced fruitful results. However, research on their mechanical properties in fire and at high temperatures is scarce. Moreover, published studies on the fire resistance of concrete-filled steel plate composite walls have not considered the impact of fire protection measures. Based on previous fire resistance research, a fire resistance test was designed in this study for four walls under the combined action of axial compression and a single-sided fire under the ISO-834 standard heating curve. Apart from that, the existing fire protections have the disadvantages of too thick, easy falling off and cracking or difficult to install. In order to eliminate the disadvantages of existing fire prevention measures, new composite fireproof structure using a rock wool board and a thin fire-retardant coating is proposed. The effects of no fireproof structures, autoclaved lightweight concrete plate fireproof structures, thick-coated fire-retardant structures, and new composite fireproof structures on the fire resistance of concrete-filled steel plate composite walls were studied experimentally. The results show that the fire resistance of the four test specimens meets the 3 h fire resistance limit of the primary load-bearing component in the specification. Based on the experimental results, reasonable fire protection methods are suggested for concrete-filled steel plate composite walls in actual projects, and an experimental basis is provided for further numerical simulation.
引用
下载
收藏
页码:389 / 403
页数:15
相关论文
共 50 条
  • [31] Experimental Research on Seismic Behaviour of the Concrete-Filled Double-Steel-Plate Composite Wall
    Luo, Yongfeng
    Guo, Xiaonong
    Li, Jian
    Xiong, Zhe
    Meng, Lei
    Dong, Niancai
    Zhang, Jun
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (11) : 1845 - 1858
  • [32] Shear capacity of concrete-filled steel plate composite coupling beams
    Hu, Hong-Song
    Nie, Jian-Guo
    Wang, Yu-Hang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 118 : 76 - 90
  • [33] Study of recycled concrete-filled steel tubular columns on the compressive capacity and fire resistance
    Wang, Haiyang
    Zha, Xiaoxiong
    Liu, Yixiang
    Luo, Chaoning
    Iu, Chi Kin
    ADVANCES IN MECHANICAL ENGINEERING, 2017, 9 (06)
  • [34] Fire Resistance Design of Concrete-Filled Steel Tube Stub Columns
    Mohamed Ghannam
    Tian Yi Song
    Fire Technology, 2021, 57 : 911 - 942
  • [35] FIRE RESPONSES AND RESISTANCE OF CONCRETE-FILLED STEEL TUBULAR FRAME STRUCTURES
    Yu, Min
    Zha, Xiaoxiong
    Ye, Jianqiao
    Li, Yi
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2010, 10 (02) : 253 - 271
  • [36] Fire Resistance Design of Concrete-Filled Steel Tube Stub Columns
    Ghannam, Mohamed
    Song, Tian Yi
    FIRE TECHNOLOGY, 2021, 57 (02) : 911 - 942
  • [37] Fire resistance of concrete-filled high strength steel tubular columns
    Wang, Ke
    Young, Ben
    THIN-WALLED STRUCTURES, 2013, 71 : 46 - 56
  • [38] EXPERIMENTAL BEHAVIOUR OF CONCRETE-FILLED STEEL TUBE COMPOSITE BEAMS
    Farhan, Ichawla A.
    Shallal, Muhaned A.
    ARCHIVES OF CIVIL ENGINEERING, 2020, 66 (02) : 235 - 251
  • [39] Fire Resistance Tests of Concrete-Filled Stainless Steel Tubular Columns
    Ghannam, Mohamed
    Tao, Zhong
    Song, Tian Yi
    Composite Construction in Steel and Concrete VII, 2016, : 468 - 478
  • [40] An experimental study of the fire performance of non-sway loaded concrete-filled steel tubular column assemblies with extended end plate connections
    Wang, YC
    Davies, JM
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (07) : 819 - 838