OCT-based dynamic mechanical analysis of vitreous humour

被引:0
|
作者
Urbanska, Magdalena A. [1 ]
Thakur, Sachin S. [2 ,3 ]
Kolenderska, Sylwia M. [4 ,5 ]
机构
[1] Massey Univ, Sch Food & Adv Technol, Palmerston North, New Zealand
[2] Univ Auckland, Fac Med & Hlth Sci, New Zealand Natl Eye Ctr, Dept Ophthalmol,Buchanan Ocular Therapeut Unit, Auckland, New Zealand
[3] Univ Auckland, Fac Med & Hlth Sci, Sch Pharm, Auckland, New Zealand
[4] Nicolaus Copernicus Univ Torun, Inst Phys, Fac Phys Astron & Informat, Ul Grudziadzka 5, PL-87100 Torun, Poland
[5] Univ Canterbury, Sch Phys & Chem Sci, Christchurch, New Zealand
关键词
Singular value decomposition; Shear wave; Rayleigh wave; Ocular biomechanics; Velocity dispersion; Viscoelasticity; ELASTOGRAPHY; DETACHMENT; FREQUENCY; RHEOLOGY;
D O I
10.1016/j.optlaseng.2023.107881
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The vitreous humour plays an important role in shock absorption, i.e. the damping of the mechanical movement, to protect the delicate tissues within the eye. However, this damping is different for movements with different frequencies/velocities. While the collective low-frequency (below 100 Hz) damping behaviour of the vitreous humour associated with the saccadic and lens movements is well-studied, to the best of our knowledge, the highfrequency damping behaviour of the vitreous humour, which represents the response of the microstructural components, is not exhaustively documented. Here, we utilise a non-destructive testing method called Optical Coherence Tomography (OCT) to measure the high-frequency (100-350 Hz, waves able to probe approximately 500 mu m distances) biomechanical behaviour of the vitreous humour. We parametrise this behaviour by calculating the shear storage modulus, shear loss modulus and phase angle. We compare these parameters to their lowfrequency counterparts obtained with a rheometer, providing a comprehensive mechanical spectrum of the vitreous humour behaviour. The processing method developed in this study and the data collected help better understand the vitreous humour shock absorption properties. Consequently, they could allow a development of better vitreous humour substitutes. The local probing of the high-frequency regime and the non-invasive character of the OCT method provide new qualities in mapping the damping behaviour.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Optical characterization of vocal folds by OCT-based laryngoscopy
    Lueerssen, Kathrin
    Wisweh, Henning
    Ptok, Martin
    Lubatschowski, Holger
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS III, 2007, 6424
  • [23] Potential use of OCT-based microangiography in clinical dermatology
    Baran, U.
    Choi, W. J.
    Wang, R. K.
    SKIN RESEARCH AND TECHNOLOGY, 2016, 22 (02) : 238 - 246
  • [24] Fully Automated OCT-based Tissue Screening System
    Pi, Shaohua
    Ganjee, Razieh
    Wang, Lingyun
    Arbuckle, Riley
    Zhao, Chengcheng
    Sahel, Jose A.
    Wang, Bingjie
    Chen, Yuanyuan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (09)
  • [25] OCT-based crystalline lens topography in accommodating eyes
    Perez-Merino, Pablo
    Velasco-Ocana, Miriam
    Martinez-Enriquez, Eduardo
    Marcos, Susana
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [26] Fully automated OCT-based tissue screening system
    Pi, Shaohua
    Ganjee, Razieh
    Wang, Lingyun
    Arbuckle, Riley K.
    Zhao, Chengcheng
    Sahel, Jose A.
    Wang, Bingjie
    Chen, Yuanyuan
    OPTICS LETTERS, 2024, 49 (16) : 4481 - 4484
  • [27] OCT-BASED THREE DIMENSIONAL MODELING OF STENT DEPLOYMENT
    Dong, Pengfei
    Prabhu, David
    Wilson, David L.
    Bezerra, Hiram G.
    Gu, Linxia
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017, VOL 3, 2018,
  • [28] Imaging: New OCT-based strategy to guide PCI
    Ummarino D.
    Nature Reviews Cardiology, 2017, 14 (1) : 2 - 2
  • [29] A Problem of Proportions in OCT-Based Morphometry and a Proposed Solution
    Sigal, Ian A.
    Schuman, Joel S.
    Ishikawa, Hiroshi
    Kagemann, Larry
    Wollstein, Gadi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (02) : 484 - 485
  • [30] Correlation Analysis between Functional Tests for Dry Eye Disease and OCT-based Tear Film Dynamic Tests in LASIK patients
    Bastan-Fabian, Daniel
    Emiliano Quiroga-Garza, Manuel
    Cesar Hernandez-Camarena, Julio
    Valdez, Jorge E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)