Prediction model for the new onset of atrial fibrillation combining features of 24-hour Holter electrocardiogram with 12-lead electrocardiogram

被引:3
|
作者
Nishimura, Tetsuro [1 ]
Senoo, Keitaro [1 ,2 ]
Makino, Masahiro [1 ]
Munakata, Jun [1 ]
Tomura, Nobunari [1 ]
Shimoo, Satoru [1 ]
Iwakoshi, Hibiki [1 ]
Shiraishi, Hirokazu [1 ,2 ]
Matoba, Satoaki [1 ,2 ]
机构
[1] Kyoto Prefectural Univ Med, Grad Sch Med Sci, Dept Cardiovasc Med, Kyoto, Japan
[2] Kyoto Prefectural Univ Med, Grad Sch Med Sci, Dept Cardiac Arrhythmia Res & Innovat, 465 Kajii Cho,Kamigyo Ku, Kyoto 6028566, Japan
来源
IJC HEART & VASCULATURE | 2023年 / 47卷
关键词
Atrial fibrillation; 12-lead electrocardiogram; 24-hour Holter electrocardiogram; PAAFS score; ATRIOVENTRICULAR-BLOCK; MANAGEMENT; INTERVAL;
D O I
10.1016/j.ijcha.2023.101245
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Several factors that predict new-onset atrial fibrillation (AF) have been investigated using the 24hour Holter electrocardiogram (ECG) and 12-lead ECG; however, these have been based on each test independently. The aim of this study was to combine findings from the two tests to create a comprehensive, easy-to-use score and to examine its validity. Methods and Results: A total of 502 patients underwent 24-hour Holter ECG and 12-lead ECG were followed up for 6.2 & PLUSMN; 3.5 years, and 66 patients developed new-onset AF. Multivariate Cox regression analyses revealed that total number of supraventricular extrasystoles (SVEs) > 100 beats/day and SVE's longest run > 3 beats on 24hour Holter ECG and PR interval > 185 ms, amplitude ratio of P wave (aVR/V1) < 1.0 and amplitude of RV5 + SV1 > 2.2 mV on 12-lead ECG were significant independent predictors for developing AF (all p < 0.01). Using these cut-off points, the PAAFS (acronym for risk factors) score was constructed by adding one point for each parameter if the patient met each of the criteria. The area under the curve (AUC) of the PAAFS score was 0.80, compared to the AUCs of 24-hour Holter ECG-only factors (0.73) and 12-lead ECG-only factors (0.72), indicating an improvement in score. The annual incidence of AF for each PAAFS score were 0.0%, 0.2%, 0.7%, 1.9%, 5.6%, and 11.1%/year for scores 0 to 5, respectively. Conclusion: The PAAFS score, which combines findings from 24-hour Holter ECG and 12-lead ECG, was superior to 24-hour Holter ECG and 12-lead ECG alone in predictive accuracy for new-onset AF.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Artificial Intelligence Predicts Atrial Fibrillation Development from the 12-lead Electrocardiogram in Heart Failure with Preserved Ejection Fraction
    Verbrugge, Frederik Hendrik
    Reddy, Yogesh N. V.
    Attia, Zachi I.
    Friedman, Paul A.
    Noseworthy, Peter A.
    Lopez-Jimenez, Francisco
    Kapa, Suraj
    Borlaug, Barry A.
    JOURNAL OF CARDIAC FAILURE, 2020, 26 (10) : S76 - S76
  • [42] Prevalence of type 1 Brugada electrocardiographic pattern evaluated on 12-lead 24-hour Holter monitoring in a large Brugada population
    Gribaudo, E.
    Giustetto, C.
    Nangeroni, G.
    Cerrato, N.
    Biava, L.
    Andrighetti, M.
    Geuna, F.
    Landi, I.
    Gaita, F.
    EUROPEAN HEART JOURNAL, 2017, 38 : 464 - 465
  • [43] Data Augmentation for Discrimination of Atrial Flutter Mechanism Using 12-Lead Surface Electrocardiogram
    Gul, Muhammad Usman
    Kadir, Kushsairy
    Azman, Muhammad Haziq Kamarul
    2021 COMPUTING IN CARDIOLOGY (CINC), 2021,
  • [44] The CE-12L: A new device for transtelephonic transmission of a 12-lead electrocardiogram
    Roth, A
    Bloch, Y
    Villa, Y
    Schlesinger, Z
    Laniado, S
    Kaplinsky, E
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (09): : 2243 - 2247
  • [45] A Detection Method of Atrial Fibrillation from 24-hour Holter-ECG Using CNN
    Kamozawa, Hidefumi
    Muroga, Sho
    Tanaka, Motoshi
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2023, 18 (04) : 577 - 582
  • [46] Semi-Supervised Learning for Automatic Atrial Fibrillation Detection in 24-Hour Holter Monitoring
    Zhang, Peng
    Chen, Yuting
    Lin, Fan
    Wu, Sifan
    Yang, Xiaoyun
    Li, Qiang
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (08) : 3791 - 3801
  • [47] LOCALIZATION OF ACCESSORY PATHWAYS FROM THE 12-LEAD ELECTROCARDIOGRAM USING A NEW ALGORITHM
    XIE, BY
    HEALD, SC
    BASHIR, Y
    KATRITSIS, D
    MURGATROYD, FD
    CAMM, AJ
    ROWLAND, E
    WARD, DE
    AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (02): : 161 - 165
  • [48] A deep neural network for 12-lead electrocardiogram interpretation outperforms a conventional algorithm, and its physician overread, in the diagnosis of atrial fibrillation
    Smith, Stephen W.
    Rapin, Jeremy
    Li, Jia
    Fleureau, Yann
    Fennell, William
    Walsh, Brooks M.
    Rosier, Arnaud
    Fiorina, Laurent
    Gardella, Christophe
    IJC HEART & VASCULATURE, 2019, 25
  • [49] Increased Risk of Antipsychotic-Related QT Prolongation During Nighttime A 24-Hour Holter Electrocardiogram Recording Study
    Watanabe, Junzo
    Suzuki, Yutaro
    Fukui, Naoki
    Ono, Shin
    Sugai, Takuro
    Tsuneyama, Nobuto
    Someya, Toshiyuki
    JOURNAL OF CLINICAL PSYCHOPHARMACOLOGY, 2012, 32 (01) : 18 - 22
  • [50] Arrhythmia risk stratification in idiopathic dilated cardiomyopathy based on echocardiography and 12-lead, signal-averaged, and 24-hour Holter electrocardiography
    Grimm, W
    Glaveris, C
    Hoffmann, J
    Menz, V
    Müller, HH
    Hufnagel, G
    Maisch, B
    AMERICAN HEART JOURNAL, 2000, 140 (01) : 43 - 51