Efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes

被引:1
|
作者
Guo, Lixin [1 ]
Li, Yuxiu [2 ]
Zhang, Mei [3 ]
Xiao, Xinhua [2 ]
Kuang, Hongyu [4 ]
Yang, Tao [3 ]
Jia, Xiaofan [1 ]
Zhang, Xianbo [1 ]
机构
[1] Chinese Acad Sci, Beijing Hosp, Inst Geriatr Med, Natl Ctr Gerontol,Dept Endocrinol, Beijing, Peoples R China
[2] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Peking Union Med Coll, Dept Endocrinol, Beijing, Peoples R China
[3] Nanjing Med Univ, Affiliated Hosp 1, Dept Endocrinol & Metab, Nanjing, Jiangsu, Peoples R China
[4] Harbin Med Univ, Affiliated Hosp 1, Dept Endocrinol, Harbin, Heilongjiang, Peoples R China
来源
关键词
clinical trial; continuous glucose monitor; sensors; type; 1; diabetes; blinded and unblinded; HYPOGLYCEMIA; THERAPY;
D O I
10.3389/fendo.2023.1110845
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveIntermittently scanned continuous glucose monitoring (isCGM) is used for unblinded or blinded monitoring of interstitial glucose. We aimed to compare the efficacy of blinded and unblinded isCGM with the FreeStyle Libre system for glycemic control in adults with type 1 diabetes (T1D). Research design and methodsThis randomized clinical trial conducted between October 2018 and September 2019 across four endocrinology practices in China included 273 adults aged >= 18 years with T1D, who were randomly divided in a 2:1 ratio into the unblinded (n = 199) or blinded isCGM group (n = 78). In the blinded group, the clinician used FreeStyle Libre Pro system for monitoring, but self-monitoring was also performed by the patients. ResultsTwo hundred sixteen (78%) participants completed the study (152 [75%] in the unblinded and 64 [82%] in the blinded group). At 12 weeks, a significant increase in TIR (3.9-10.0 mmol/L) was only observed in the unblinded group, along with a significant decrease in hyperglycemia (>13.9 mmol/L), hypoglycemia (<3.0 mmol/L), glycemic variability. Further, the mean HbA1c reduction from baseline to 12 weeks was 0.5% in the unblinded isCGM group and 0.4% in the blinded isCGM group respectively (P < 0.001), but the significance did not remain after adjustment for between-group differences. Finally, 99.5% of the blinded isCGM values and 93.8% the of unblinded isCGM values were obtained at the final visit. ConclusionsThe unblinded isCGM system was associated with benefits for glucose management, but nearly 100% of the attempted profiles were obtained successfully with the blinded isCGM system. Thus, combining real-time and retrospective data with isCGM might be the most impactful way to utilize flash glycemic monitoring devices.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Addition of intermittently scanned continuous glucose monitoring to standard care in a cohort of pregnant women with type 1 diabetes: effect on glycaemic control and pregnancy outcomes
    Verónica Perea
    Maria José Picón
    Ana Megia
    Maria Goya
    Ana Maria Wägner
    Begoña Vega
    Nuria Seguí
    Maria Dolores Montañez
    Irene Vinagre
    Diabetologia, 2022, 65 : 1302 - 1314
  • [42] Addition of intermittently scanned continuous glucose monitoring to standard care in a cohort of pregnant women with type 1 diabetes: effect on glycaemic control and pregnancy outcomes
    Perea, Veronica
    Picon, Maria Jose
    Megia, Ana
    Goya, Maria
    Wagner, Ana Maria
    Vega, Begona
    Segui, Nuria
    Montanez, Maria Dolores
    Vinagre, Irene
    DIABETOLOGIA, 2022, 65 (08) : 1302 - 1314
  • [43] Glycemic Control with Early Initiation of Continuous Glucose Monitoring System in Adults with Recently Diagnosed Type 1A Diabetes
    Shah, Viral N.
    Gallo, Tyler
    Snell-Bergeon, Janet K.
    DIABETES, 2017, 66 : A237 - A238
  • [44] Effect of Continuous Glucose Monitoring on Glycemic Control in Adolescents and Young Adults With Type 1 Diabetes A Randomized Clinical Trial
    Laffel, Lori M.
    Kanapka, Lauren G.
    Beck, Roy W.
    Bergamo, Katherine
    Clements, Mark A.
    Criego, Amy
    DeSalvo, Daniel J.
    Goland, Robin
    Hood, Korey
    Liljenquist, David
    Messer, Laurel H.
    Monzavi, Roshanak
    Mouse, Thomas J.
    Prahalad, Priya
    Sherr, Jennifer
    Simmons, Jill H.
    Wadwa, R. Paul
    Weinstock, Ruth S.
    Willi, Steven M.
    Miller, Kellee M.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2020, 323 (23): : 2388 - 2396
  • [45] Continuous glucose monitoring (CGM) satisfaction and its effect on mental health and glycemic control in adults with type 1 diabetes
    Lukacs, Andrea
    Szerencsi, Laura Brigitta
    Barkai, Laszlo
    PHYSIOLOGY INTERNATIONAL, 2022, 109 (04) : 501 - 510
  • [46] Preserved C-peptide secretion is associated with higher time in range (TIR) on intermittently scanned continuous glucose monitoring in Chinese adults with type 1 diabetes
    Liu, Wei
    Ma, Yunke
    Cai, Xiaoling
    Zhu, Yu
    Zhang, Mingxia
    Li, Juan
    Chen, Jing
    Shi, Dawei
    Ji, Linong
    ENDOCRINE CONNECTIONS, 2022, 11 (11)
  • [47] Performance of the Intermittently Scanned Continuous Glucose Monitoring (isCGM) System during a High Oral Glucose Challenge in Adults with Type 1 Diabetes-A Prospective Secondary Outcome Analysis
    Moser, Othmar
    Tripolt, Norbert
    Pferschy, Peter
    Obermayer, Anna
    Kojzar, Harald
    Mueller, Alexander
    Yildirim, Hakan
    Sourij, Caren
    Eckstein, Max
    Sourij, Harald
    BIOSENSORS-BASEL, 2021, 11 (01):
  • [48] Effects of intermittently scanned continuous glucose monitoring on blood glucose control and the production of urinary ketone bodies in pregestational diabetes mellitus
    Shu-ying Li
    Hang Guo
    Yi Zhang
    Pei Li
    Pei Zhou
    Li-rong Sun
    Jing Li
    Li-ming Chen
    Diabetology & Metabolic Syndrome, 13
  • [49] Effects of intermittently scanned continuous glucose monitoring on blood glucose control and the production of urinary ketone bodies in pregestational diabetes mellitus
    Li, Shu-ying
    Guo, Hang
    Zhang, Yi
    Li, Pei
    Zhou, Pei
    Sun, Li-rong
    Li, Jing
    Chen, Li-ming
    DIABETOLOGY & METABOLIC SYNDROME, 2021, 13 (01):
  • [50] Cost-utility analysis of Dexcom G6 real-time continuous glucose monitoring versus FreeStyle Libre 1 intermittently scanned continuous glucose monitoring in adults with type 1 diabetes in Belgium
    Visser, Margaretha M.
    Van Muylder, Astrid
    Charleer, Sara
    Isitt, John J.
    Roze, Stephane
    De Block, Christophe
    Maes, Toon
    Vanhaverbeke, Gerd
    Nobels, Frank
    Keymeulen, Bart
    Mathieu, Chantal
    Luyten, Jeroen
    Gillard, Pieter
    Verhaeghe, Nick
    DIABETOLOGIA, 2024, 67 (04) : 650 - 662