Approach for Non-Intrusive Detection of the Fit of Orthopaedic Devices Based on Vibrational Data

被引:1
|
作者
Neupetsch, Constanze [1 ,2 ,3 ]
Hensel, Eric [1 ]
Heinke, Andreas [4 ]
Stapf, Tom [1 ]
Stecher, Nico [4 ]
Malberg, Hagen [4 ]
Heyde, Christoph-Eckhard [3 ]
Drossel, Welf-Guntram [1 ,2 ]
机构
[1] Fraunhofer Inst Machine Tools & Forming Technol, D-09126 Chemnitz, Germany
[2] Tech Univ Chemnitz, Fac Mech Engn, Professorship Adaptron & Lightweight Design, D-09111 Chemnitz, Germany
[3] Univ Leipzig, Med Ctr, Dept Orthopaed Trauma & Plast Surg, D-04103 Leipzig, Germany
[4] Tech Univ Dresden, Inst Biomed Engn, D-01307 Dresden, Germany
关键词
socket fit; lower-limb prosthesis; transfemoral amputation; residual limb; local pressure mark; structural dynamics; measurement method; acoustic sensor; frequency response analysis; LOWER-LIMB AMPUTATIONS; INTERFACE PRESSURE; FORCE-SENSOR; SOCKET; SHEAR; PROSTHESES;
D O I
10.3390/s23146500
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The soft tissues of residual limb amputees are subject to large volume fluctuations over the course of a day. Volume fluctuations in residual limbs can lead to local pressure marks, causing discomfort, pain and rejection of prostheses. Existing methods for measuring interface stress encounter several limitations. A major problem is that the measurement instrumentation is applied in the sensitive interface between the prosthesis and residual limb. This paper presents the principle investigation of a non-intrusive technique to evaluate the fit of orthopaedic prosthesis sockets in transfemoral amputees based on experimentally obtained vibrational data. The proposed approach is based on changes in the dynamical behaviour detectable at the outer surface of prostheses; thus, the described interface is not affected. Based on the experimental investigations shown and the derived results, it can be concluded that structural dynamic measurements are a promising non-intrusive technique to evaluate the fit of orthopaedic prosthesis sockets in transfemoral amputee patients. The obtained resonance frequency changes of 2% are a good indicator of successful applicabilityas these changes can be detected without the need for complex measurement devices.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Uncertainty propagation for nonlinear vibrations: A non-intrusive approach
    Panunzio, A. M.
    Salles, Loic
    Schwingshackl, C. W.
    JOURNAL OF SOUND AND VIBRATION, 2017, 389 : 309 - 325
  • [42] Heart Rate Variability for Non-Intrusive Cybersickness Detection
    Lobo, Paula Reyero
    Perez, Pablo
    PROCEEDINGS OF THE 2022 ACM INTERNATIONAL CONFERENCE ON INTERACTIVE MEDIA EXPERIENCES, IMX 2022, 2022, : 221 - 228
  • [43] Neutron based non-intrusive inspection techniques
    Gozani, T
    NEUTRONS IN RESEARCH AND INDUSTRY, INTERNATIONAL CONFERENCE, 1997, 2867 : 174 - 181
  • [44] Survey of non-intrusive face spoof detection methods
    Patil, Pooja R.
    Kulkarni, Subhash S.
    MULTIMEDIA TOOLS AND APPLICATIONS, 2021, 80 (10) : 14693 - 14721
  • [45] A non-intrusive sand detection system for subsea installation
    Fossum, TG
    Helgesen, O
    SUBSEA CONTROL AND DATA ACQUISITION, 1996, : 157 - 169
  • [46] Component forensics of digital cameras: A non-intrusive approach
    Swaminathan, Ashwin
    Wu, Min
    Liu, K. J. Ray
    2006 40TH ANNUAL CONFERENCE ON INFORMATION SCIENCES AND SYSTEMS, VOLS 1-4, 2006, : 1194 - 1199
  • [47] Outlier Detection in Non-intrusive ECG Biometric System
    Lourenco, Andre
    Silva, Hugo
    Carreiras, Carlos
    Fred, And
    IMAGE ANALYSIS AND RECOGNITION, 2013, 7950 : 43 - 52
  • [48] Hollow village detection method based on non-intrusive power load monitoring
    Liu, Rui
    Wang, Donglai
    Chen, Yan
    Guo, Rui
    Shi, Jiaqi
    ENERGY REPORTS, 2023, 9 : 407 - 415
  • [49] Driver drowsiness detection based on non-intrusive metrics considering individual specifics
    Wang, Xuesong
    Xu, Chuan
    ACCIDENT ANALYSIS AND PREVENTION, 2016, 95 : 350 - 357
  • [50] Hollow village detection method based on non-intrusive power load monitoring
    Liu, Rui
    Wang, Donglai
    Chen, Yan
    Guo, Rui
    Shi, Jiaqi
    ENERGY REPORTS, 2023, 9 : 407 - 415