Approach for Non-Intrusive Detection of the Fit of Orthopaedic Devices Based on Vibrational Data

被引:1
|
作者
Neupetsch, Constanze [1 ,2 ,3 ]
Hensel, Eric [1 ]
Heinke, Andreas [4 ]
Stapf, Tom [1 ]
Stecher, Nico [4 ]
Malberg, Hagen [4 ]
Heyde, Christoph-Eckhard [3 ]
Drossel, Welf-Guntram [1 ,2 ]
机构
[1] Fraunhofer Inst Machine Tools & Forming Technol, D-09126 Chemnitz, Germany
[2] Tech Univ Chemnitz, Fac Mech Engn, Professorship Adaptron & Lightweight Design, D-09111 Chemnitz, Germany
[3] Univ Leipzig, Med Ctr, Dept Orthopaed Trauma & Plast Surg, D-04103 Leipzig, Germany
[4] Tech Univ Dresden, Inst Biomed Engn, D-01307 Dresden, Germany
关键词
socket fit; lower-limb prosthesis; transfemoral amputation; residual limb; local pressure mark; structural dynamics; measurement method; acoustic sensor; frequency response analysis; LOWER-LIMB AMPUTATIONS; INTERFACE PRESSURE; FORCE-SENSOR; SOCKET; SHEAR; PROSTHESES;
D O I
10.3390/s23146500
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The soft tissues of residual limb amputees are subject to large volume fluctuations over the course of a day. Volume fluctuations in residual limbs can lead to local pressure marks, causing discomfort, pain and rejection of prostheses. Existing methods for measuring interface stress encounter several limitations. A major problem is that the measurement instrumentation is applied in the sensitive interface between the prosthesis and residual limb. This paper presents the principle investigation of a non-intrusive technique to evaluate the fit of orthopaedic prosthesis sockets in transfemoral amputees based on experimentally obtained vibrational data. The proposed approach is based on changes in the dynamical behaviour detectable at the outer surface of prostheses; thus, the described interface is not affected. Based on the experimental investigations shown and the derived results, it can be concluded that structural dynamic measurements are a promising non-intrusive technique to evaluate the fit of orthopaedic prosthesis sockets in transfemoral amputee patients. The obtained resonance frequency changes of 2% are a good indicator of successful applicabilityas these changes can be detected without the need for complex measurement devices.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Non-Intrusive Detection of Drowsy Driving Based on Eye Tracking Data
    Zandi, Ali Shahidi
    Quddus, Azhar
    Prest, Laura
    Comeau, Felix J. E.
    TRANSPORTATION RESEARCH RECORD, 2019, 2673 (06) : 247 - 257
  • [2] Non-intrusive condition monitoring based on event detection and functional data clustering
    Bermeo-Ayerbe, Miguel Angel
    Ocampo-Martinez, Carlos
    Diaz-Rozo, Javier
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2023, 124
  • [3] Early diagnosis of frailty: Technological and non-intrusive devices for clinical detection
    Anabitarte-Garcia, Francisco
    Reyes-Gonzalez, Luis
    Rodriguez-Cobo, Luis
    Fernandez-Viadero, Carlos
    Somonte-Segares, Silvia
    Diez-del-Valle, Sara
    Mandaluniz, Eneritz
    Garcia-Garcia, Roberto
    Lopez-Higuera, Jose M.
    AGEING RESEARCH REVIEWS, 2021, 70
  • [4] A Non-Intrusive Approach for Indoor Occupancy Detection in Smart Environments
    Abade, Bruno
    Abreu, David Perez
    Curado, Marilia
    SENSORS, 2018, 18 (11)
  • [5] A Novel Approach for Event Detection in Non-intrusive Load Monitoring
    Zhu, Zhicheng
    Wei, Zhiqiang
    Yin, Bo
    Zhang, Shuai
    Wang, Xiao
    2017 IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2017,
  • [6] A Hybrid Event Detection Approach for Non-Intrusive Load Monitoring
    Lu, Mengqi
    Li, Zuyi
    IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (01) : 528 - 540
  • [7] Non-Intrusive In-Service PMD Measurements: A Novel Approach Based on Coherent Detection
    Lecoeuche, V.
    Sauron, F.
    Roa, P.
    Cebollada, A.
    Cuenot, B.
    Champavere, A.
    Masselin, O.
    Heismann, F.
    2011 37TH EUROPEAN CONFERENCE AND EXHIBITION ON OPTICAL COMMUNICATIONS (ECOC 2011), 2011,
  • [8] Detection techniques for non-intrusive testing
    Humphrey, DL
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY - PROCEEDINGS OF THE FOURTEENTH INTERNATIONAL CONFERENCE, PTS 1 AND 2, 1997, (392): : 857 - 860
  • [9] A Machine Learning Approach to Indoor Occupancy Detection Using Non-Intrusive Environmental Sensor Data
    Zemouri, Sofiane
    Gkoufas, Yiannis
    Murphy, John
    3RD INTERNATIONAL CONFERENCE ON BIG DATA AND INTERNET OF THINGS (BDIOT 2019), 2018, : 70 - 74
  • [10] Efficient non-intrusive divergence detection techniques in an in-service non-intrusive measurement device
    Ng, WP
    Elmirghani, JMH
    Broom, S
    ELECTRONICS LETTERS, 2000, 36 (23) : 1980 - 1981