Electromechanical Impedance Instrumented Wearable Piezoelectric Ring-Type Sensor for Bolted Connection Monitoring

被引:8
|
作者
Wu, Jianchao [1 ]
Chen, Yixuan [2 ]
Wang, Jianjun [3 ]
Liu, Zhishun [4 ]
Li, Weijie [4 ]
机构
[1] China Earthquake Adm, Hubei Key Lab Earthquake Early Warning, Inst Seismol, Wuhan 430071, Peoples R China
[2] Southeast Univ, Sch Civil Engn, Nanjing 210096, Peoples R China
[3] Univ Sci & Technol Beijing, Dept Appl Mech, Beijing 100083, Peoples R China
[4] Dalian Univ Technol, Sch Civil Engn, Dalian 116024, Peoples R China
基金
中国国家自然科学基金;
关键词
Fasteners; Impedance; Monitoring; Sensors; Electromagnetic interference; Biomedical monitoring; Impedance measurement; Bolted connection monitoring; electromechanical impedance (EMI); lead zirconate titanate (PZT); wearable piezoelectric ring (WPR); LOOSENESS DETECTION; VIBROACOUSTIC MODULATION; DAMAGE ASSESSMENT; TRANSDUCERS; CONCRETE; MODEL;
D O I
10.1109/JSEN.2023.3275922
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to the loss of preload, structural failure caused by bolt loosening is common in engineering structures. Effective monitoring of bolted connections is of great importance in providing early warning to the structural maintenance department. In this study, a novel and reusable electromechanical impedance (EMI) instrumented wearable piezoelectric ring (WPR) was proposed to detect bolted connection loosening. In the experimental investigation, the EMI spectra of three identical WPRs during the bolt-loosening process were acquired and analyzed. It was concluded that bolt looseness changes can be qualitatively and quantitatively characterized by conductance spectra. Specifically, the resonance frequency and amplitude at certain frequencies were reduced correspondingly as bolts loosen. This was further validated by finite element model (FEM) simulation results. Moreover, two statistical metrics including mean absolute percentage deviation (MAPD) and root mean square deviation (RMSD) were adopted to evaluate different degrees of bolted connections quantitatively. Both metrics showed an increasing tendency during the bolt loosening process in three different frequency bands. It was found that both metrics demonstrated a significant linear correlation with bolt torque variations. Both of them serve as reliable indicators to detect loose bolts in the bolted connection. The present work verifies the feasibility and applicability of using EMI-instrumented WPR to monitor bolted connections.
引用
收藏
页码:14872 / 14881
页数:10
相关论文
共 50 条
  • [21] Study of a Ring-Type Surgical Pleth Index Monitoring System Based on Flexible PPG Sensor
    Zhou, Congcong
    Wang, Hongwei
    Zhang, Yiming
    Ye, Xuesong
    IEEE SENSORS JOURNAL, 2021, 21 (13) : 14360 - 14368
  • [22] Optimization Design and Load Characteristics of the Ring-Type Piezoelectric Ceramic Transformer
    Cao, Hui
    Lin, Shuyu
    Xu, Jie
    ACTA ACUSTICA UNITED WITH ACUSTICA, 2016, 102 (01) : 8 - 15
  • [23] Performance evaluation of a valveless micropump driven by a ring-type piezoelectric actuator
    Zhang, T
    Wang, QM
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (02) : 463 - 473
  • [24] Piezoelectric cement sensor-based electromechanical impedance technique for the chloride ion content monitoring of hardened concrete
    Cheng, You-Shen
    Pan, Huang Hsing
    Wu, Chung-Hao
    NONDESTRUCTIVE CHARACTERIZATION AND MONITORING OF ADVANCED MATERIALS, AEROSPACE, CIVIL INFRASTRUCTURE, AND TRANSPORTATION XVII, 2023, 12487
  • [25] Preload Monitoring in Bolted Connection Using Piezoelectric-Based Smart Interface
    Huynh, Thanh-Canh
    Dang, Ngoc-Loi
    Kim, Jeong-Tae
    SENSORS, 2018, 18 (09)
  • [26] Novel Wearable and Wireless Ring-Type Pulse Oximeter with Multi-Detectors
    Huang, Cheng-Yang
    Chan, Ming-Che
    Chen, Chien-Yue
    Lin, Bor-Shyh
    SENSORS, 2014, 14 (09) : 17586 - 17599
  • [27] REAL-TIME MISSED SEEDING MONITORING PLANTER BASED ON RING-TYPE CAPACITANCE DETECTION SENSOR
    Kaikang, Chen
    Bo, Zhao
    Liming, Zhou
    Lili, Wang
    Yahui, Wang
    Yanwei, Yuan
    Yongjun, Zheng
    INMATEH-AGRICULTURAL ENGINEERING, 2021, 64 (02): : 279 - 288
  • [28] Electromechanical impedance sensor for in vivo monitoring the body reaction to implants
    Giurgiutiu, V
    Friedman, H
    Bender, J
    Borg, T
    Yost, MJ
    Newcomb, W
    Black, A
    Bost, J
    Stewart, CD
    JOURNAL OF INVESTIGATIVE SURGERY, 2004, 17 (05) : 257 - 270
  • [29] INDUSTRIAL FLUID DEGRADATION MONITORING WITH AN ELECTROMECHANICAL IMPEDANCE ACTIVE SENSOR
    Lu, Runye
    Shen, Yanfeng
    PROCEEDINGS OF ASME 2023 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2023, VOL 6, 2023,
  • [30] Real-Time Heart Rate Monitoring System based on Ring-Type Pulse Oximeter Sensor
    Park, Seung-Min
    Kim, Jun-Yeup
    Ko, Kwang-Eun
    Jang, In-Hun
    Sim, Kwee-Bo
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2013, 8 (02) : 376 - 384