Impact of Varying Transcutaneous Electrical Stimulation Pulse Frequency on Swallow Timing Measures in Healthy Adults

被引:0
|
作者
Barikroo, Ali [1 ]
Zinser, Alyssa [1 ]
机构
[1] Kent State Univ, Sch Hlth Sci, Speech Pathol & Audiol Program, Swallowing Physiol & Rehabil Res Lab, POB 5190, Kent, OH 44242 USA
关键词
Deglutition; Deglutition disorder; Transcutaneous electrical stimulation; Kinematics; VIDEOFLUOROSCOPIC ANALYSIS; BOLUS VOLUME; DYSPHAGIA; OLDER; YOUNG; ASPIRATION; PHYSIOLOGY; EFFICIENCY; VISCOSITY; MANEUVER;
D O I
10.1007/s00455-023-10601-1
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The impaired swallow timing subsequent to dysphagia or aging can potentially endanger swallowing safety and efficiency. Preliminary evidence has suggested that transcutaneous electrical stimulation (TES) may have the potential to affect swallow timing. However, limited knowledge exists regarding which TES parameters can optimize swallow timing. Pulse frequency is one of the primary TES parameters that can affect the quality of muscle contraction. Yet, no clear information exists regarding how changing pulse frequency impacts the timing of swallowing events. This study aimed to investigate the varying effects of submental TES pulse frequency on swallowing events during and post-15-min TES administration. Twenty-six healthy individuals between the ages of 20 and 54 participated in this study and were assigned to high pulse frequency (HPF) (80 Hz) or low pulse frequency (LPF) (30 Hz) groups. Videofluoroscopic swallowing study (VFSS) was used to record swallowing. Three trials of 10 mL pureed mixed with barium sulfate were presented under three different conditions, including pre-TES, during TES, and post-TES, in which measures were taken following 15 min of TES delivery. The swallow timing events that were measured in each condition were time to maximum hyoid elevation, time to maximum laryngeal elevation, laryngeal vestibule closure reaction time (LVCrt), laryngeal vestibule closure duration (LVCd), time to maximum pharyngeal constriction, and pharyngoesophageal segment (PES) opening duration. No significant pulse frequency effect was found on any swallow timing measures during or after 15 min of TES. Both protocols decreased the duration of some swallowing events during TES including time to maximum hyoid elevation [p < 0.017, & eta;p2 = 0.185], LVCrt [p < 0.032, & eta;p2 = 0.158], and time to maximum pharyngeal constriction [p < 0.034, & eta;p2 = 0.155]. None of the significant TES effects were continued when TES ceased after 15 min. Overall, both protocols have comparable immediate effects on shortening the duration of some swallowing events during TES. Future clinical trials should examine whether these physiologic timing changes can lead to safer and more efficient swallows in patients with dysphagia.
引用
收藏
页码:140 / 149
页数:10
相关论文
共 50 条
  • [31] THE EFFECT OF TRANSCUTANEOUS SUBMENTAL ELECTRICAL STIMULATION ON THE BLOOD PRESSURE RESPONSE IN HEALTHY VOLUNTEERS
    Alsharifi, A.
    Carter, N.
    Akbar, I.
    Pascual, M.
    Cheng, M.
    Pengo, M.
    Parati, G.
    Kaltsakas, G.
    Rafferty, G.
    Steier, J.
    THORAX, 2022, 77 : A77 - A77
  • [32] The effect of transcutaneous submental electrical stimulation on the blood pressure response in healthy volunteers
    Alsharifi, A.
    Carter, N.
    Akbar, I
    Pascual, M. Serna
    Cheng, M.
    Pengo, M.
    Parati, G.
    Rafferty, G.
    Steier, J.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [33] Impact of transcutaneous vagus nerve stimulation on healthy cognitive and brain aging
    Trifilio, Erin
    Shortell, Destin
    Olshan, Sarah
    O'Neal, Alexandria
    Coyne, Jozee
    Lamb, Damon
    Porges, Eric
    Williamson, John
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [34] NEUROMUSCULAR FATIGUE AFTER LOW- AND MEDIUM-FREQUENCY ELECTRICAL STIMULATION IN HEALTHY ADULTS
    Alves De Oliveira, Pedro Ferreira
    Quagliotti Durigan, Joao Luiz
    Guida Modesto, Karenina Arrais
    Bottaro, Martim
    Babault, Nicolas
    MUSCLE & NERVE, 2018, 58 (02) : 293 - 299
  • [35] Impact of low frequency transcutaneous electrical nerve stimulation on symptomatic diabetic neuropathy using the new Salutaris® device
    Forst, T
    Nguyen, M
    Forst, S
    Disselhoff, B
    Pohlmann, T
    Pfützner, A
    DIABETES NUTRITION & METABOLISM, 2004, 17 (03) : 163 - 168
  • [36] The Effect of Transcutaneous Spinal Cord Stimulation on Standing Postural Control in Healthy Adults
    Carrera, Robert M.
    Omofuma, Isirame
    Yasin, Bushra
    Agrawal, Sunil K.
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2022, 7 (03): : 8268 - 8275
  • [37] The Effect of Transcutaneous Spinal Cord Stimulation on Standing Postural Control in Healthy Adults
    Carrera, Robert M.
    Omofuma, Isirame
    Yasin, Bushra
    Agrawal, Sunil K.
    2022 9TH IEEE RAS/EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB 2022), 2022,
  • [38] Induced frequency response to single pulse electrical stimulation
    Sinai, A
    Koubeissi, M
    Crone, N
    NEUROLOGY, 2006, 66 (05) : A208 - A208
  • [39] Ultrahigh frequency transcutaneous electrical nerve stimulation for neuropathic pain alleviation and neuromodulation
    Chen, Szu-Han
    Lin, Yu-Wen
    Tseng, Wan-Ling
    Lin, Wei-Tso
    Lin, Sheng-Che
    Hsueh, Yuan-Yu
    NEUROTHERAPEUTICS, 2024, 21 (03)
  • [40] Differential Frequency Effects of Strong Nonpainful Transcutaneous Electrical Nerve Stimulation on Experimentally Induced Ischemic Pain in Healthy Human Participants
    Chen, Chih-Chung
    Johnson, Mark I.
    CLINICAL JOURNAL OF PAIN, 2011, 27 (05): : 434 - 441