A technique for splinting implant impression posts by using nylon sutures

被引:0
|
作者
Kurian, Nirmal [1 ,2 ]
Gandhi, Nitasha [1 ]
Daniel, Angleena Y. [1 ]
Varghese, Kevin George [1 ]
机构
[1] Christian Dent Coll, Dept Prosthodont & Crown & Bridge, Ludhiana, Punjab, India
[2] Christian Dent Coll, Dept Prosthodont & Crown & Bridge, Ludhiana 141008, Punjab, India
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 129卷 / 04期
关键词
DENTAL-FLOSS; ACCURACY; ARCH; PROSTHESES;
D O I
10.1016/j.prosdent.2021.10.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
[No abstract available]
引用
收藏
页码:669 / 670
页数:2
相关论文
共 50 条
  • [21] Accuracy of complete-arch digital implant impression with or without scanbody splinting: An in vitro study
    Pozzi, Alessandro
    Arcuri, Lorenzo
    Lio, Fabrizio
    Papa, Andrea
    Nardi, Alessandra
    Londono, Jimmy
    JOURNAL OF DENTISTRY, 2022, 119
  • [22] A technique to improve positioning of the transmandibular posts of the transmandibular implant
    Franco, PF
    Steinberg, MJ
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 56 (06) : 797 - 797
  • [23] Effects of Implant System, Impression Technique, and Impression Material on Accuracy of the Working Cast
    Wegner, Kerstin
    Weskott, Katharina
    Zenginel, Martha
    Rehmann, Peter
    Woestmann, Bernd
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (04) : 989 - 995
  • [24] Effect of splinting scan bodies on trueness of complete-arch implant impression using different intraoral scanners: an in vitro study
    Retana, Luciano
    Nejat, Amir H.
    Pozzi, Alessandro
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2023, 26 (01) : 19 - 28
  • [25] Spongy floss impregnated with light-polymerizing gel to splint implant impression posts
    Majchrowicz, Michael
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (02): : 176 - 177
  • [26] Accuracy of edentulous full-arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry
    Cheng, Jing
    Zhang, Haidong
    Liu, Hailin
    Li, Junying
    Wang, Hom-Lay
    Tao, Xian
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (05) : 560 - 572
  • [27] An Implant-Transfer Technique Without Impression Material
    Assuncao, Wirley Goncalves
    Gomes, Erica Alves
    Delben, Juliana Aparecida
    dos-Santos, Paulo Henrique
    Ricardo Barao, Valentim Adelino
    Tabata, Lucas Fernando
    JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (04) : 1274 - 1276
  • [28] An alternative impression technique for implant-retained overdentures
    Uludag, Bulent
    Celik, Gozde
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 96 (05): : 377 - 378
  • [29] An impression technique for implant-retained orbital prostheses
    Karakoca, Secil
    Aydin, Cemal
    Yilmaz, Handan
    Korkmaz, Turan
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (01): : 52 - 55
  • [30] Digital Implant Impression Technique Accuracy: A Systematic Review
    Alikhasi, Marzieh
    Alsharbaty, Mohammed Hussein M.
    Moharrami, Mohammad
    IMPLANT DENTISTRY, 2017, 26 (06) : 929 - 935