Longer Screws Can Reduce the Stress on the Upper Instrumented Vertebra With Long Spinal Fusion Surgery: A Finite Element Analysis Study

被引:6
|
作者
Oe, Shin [1 ]
Narita, Kengo [2 ]
Hasegawa, Kazuhiro [3 ]
Natarajan, Raghu N. [4 ]
Yamato, Yu [1 ]
Hasegawa, Tomohiko [5 ]
Yoshida, Go [5 ]
Banno, Tomohiro [5 ]
Arima, Hideyuki [5 ]
Mihara, Yuki [5 ]
Ushirozako, Hiroki [5 ]
Ide, Koichiro [5 ]
Yamada, Tomohiro [5 ]
Watanabe, Yuh [5 ]
Matsuyama, Yukihiro [5 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Orthoped Surg, Div Geriatr Musculoskeletal Hlth, Shizuoka, Japan
[2] Maruemu Works Co Ltd, Dept Med, Osaka, Japan
[3] Niigata Spine Surg Ctr, Niigata, Japan
[4] Rush Univ, Med Ctr, Chicago, IL 60612 USA
[5] Hamamatsu Univ Sch Med, Dept Orthoped Surg, Shizuoka, Japan
关键词
finite element analysis; upper instrumented vertebral fracture; proximal junctional failure; occupancy rate of pedicle screw; adult spinal deformity; LUMBAR FUSION; PEDICLE; FIXATION; FRACTURE; RISK; CONSTRUCTS; BEHAVIOR; LEVEL; MODEL; LOAD;
D O I
10.1177/21925682211018467
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: A finite element analysis study. Objective: Of proximal junctional failure, upper instrumented vertebra (UIV) fracture can causes severe spinal cord injury. Previously, we reported that higher occupancy rate of pedicle screw (ORPS) at UIV prevented UIV fracture in adult spinal deformity surgery; we had not yet tested this finding using a biomechanical study. The purpose of present study was to measure the differences in loads on the UIV according to the length of PS and ORPS. Methods: We designed an FE model of a lumbar spine (L1-S1) using FE software. The PS was set from L2 to S1 and connected the rod. The FE model simulated flexion (8 Nm) to investigate the loads at UIV (L2) according to the length of the PS. There were 5 screw lengths examined: 40 (ORPS 36.4%), 45 (48.5%), 50 (66.7%), 55 (81.8%), and 60 mm (93.9%). Results: Stress with bending motion was likely to occur at the upper front edge of the vertebral body, the pedicles, and the screw insertion point. The maximum equivalent stress according to screw lengths of 40, 45, 50, 55, and 60 mm were 45.6, 37.2, 21.6, 13.3, and 14.8 MPa, respectively. The longer screw, the less stress was applied to UIV. No remarkable change was observed between the screw lengths of 55 and 60 mm. Conclusions: Increasing ORPS to 81.8% or more reduced the load on the UIV. To prevent UIV fracture, the PS length in the UIV should be more than ORPS 81.8%.
引用
收藏
页码:1072 / 1079
页数:8
相关论文
共 39 条
  • [21] Rod Stress Prediction in Spinal Alignment Surgery with Different Supplementary Rod Constructing Techniques: A Finite Element Study
    Xu, Ming
    Scholl, Thomas
    Berjano, Pedro
    Cruz, Jazmin
    Yang, James
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2018, VOL 1B, 2018,
  • [22] Finite Element Analysis of Instrumented Posterior Lumbar Interbody Fusion Cages for Reducing Stress Shielding Effects: Comparison of the CFRP cage and Titanium cage
    Kang, Kyung-Tak
    Chun, Heoung-Jae
    Kim, Ho-Joong
    Yeom, Jin-S.
    Park, Kyoung-Mi
    Hwang, In-Han
    Lee, Kwang-Ill
    COMPOSITES RESEARCH, 2012, 25 (04): : 98 - 104
  • [23] Biomechanical Analysis of a Long-Segment Fusion in a Lumbar Spine-A Finite Element Model Study
    Natarajan, Raghu N.
    Watanabe, Kei
    Hasegawa, Kazuhiro
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (09):
  • [24] Impact of osteoporosis and Cement-Augmented fusion on adjacent spinal levels Post-Fusion Surgery: Patient-Specific finite element analysis
    Khalaf, Kinda
    Nikkhoo, Mohammad
    Shams, Shohreh
    Niu, Chi-Chien
    Cheng, Chih- Hsiu
    JOURNAL OF BIOMECHANICS, 2024, 166
  • [25] Risk Factor Analysis of Deep Surgical Site Infection After Posterior Instrumented Fusion Surgery for Spinal Trauma: A Multicenter Observational Study
    Ogihara, Satoshi
    Yamazaki, Takashi
    Shiibashi, Michio
    Maruyama, Toru
    Chikuda, Hirotaka
    Miyoshi, Kota
    Inanami, Hirohiko
    Oshima, Yasushi
    Azuma, Seiichi
    Kawamura, Naohiro
    Yamakawa, Kiyofumi
    Hara, Nobuhiro
    Morii, Jiro
    Okazaki, Rentaro
    Takeshita, Yujiro
    Sato, Kei
    Tanaka, Sakae
    Saita, Kazuo
    WORLD NEUROSURGERY, 2020, 134 : E524 - E529
  • [26] Biomechanical Analysis of Adjacent Segments after Spinal Fusion Surgery Using a Geometrically Parametric Patient-Specific Finite Element Model
    Wang, Yuming
    Shen, Qianyi
    Liang, Chang
    Shen, Yanzhu
    Tang, Xiangsheng
    Yi, Ping
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (203):
  • [27] Chewing Stress Developed in Upper Anterior Teeth with Root end Resection. A Finite Element Analysis Study
    Iliescu, Al. A.
    Petcu, C. M.
    Nitoi, D.
    Iliescu, A.
    CHIRURGIA, 2013, 108 (03) : 389 - 395
  • [28] Can Degradation of Adhesive Interfaces Due to Water Storage Affect Stress Distributions? A Finite-Element Stress Analysis Study
    Belli, Sema
    Eraslan, Oguz
    Eskitascioglu, Gurcan
    JOURNAL OF ADHESIVE DENTISTRY, 2016, 18 (06): : 521 - 527
  • [29] Early mobilization can reduce the incidence of surgical site infections in patients undergoing spinal fusion surgery: A nested case-control study
    Zhang, Haoran
    Zhao, Yiwei
    Du, You
    Yang, Yang
    Zhang, Jianguo
    Wang, Shengru
    AMERICAN JOURNAL OF INFECTION CONTROL, 2024, 52 (06) : 644 - 649
  • [30] Is Preventative Long-Segment Surgery for Multi-Level Spondylolysis Necessary? A Finite Element Analysis Study
    Mo, Jianqiang
    Zhang, Wen
    Zhong, Dongyan
    Xu, Hao
    Wang, Lan
    Yu, Jia
    Luo, Zongping
    PLOS ONE, 2016, 11 (02):