Reliability analysis of an Electronic Portal Imaging Device (EPID) of a linear accelerator

被引:0
|
作者
Gouveia, Clesia [1 ,2 ]
Sobral, Jose [1 ,3 ]
机构
[1] ISEL, Lisbon, Portugal
[2] Joaquim Chaves Saitde JCS, Lisbon, Portugal
[3] CENTEC, Lisbon, Portugal
关键词
EPID; reliability; failure; Weibull; DOSIMETRY;
D O I
10.1109/ENBENG58165.2023.10175354
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Electronic Portal Imaging Device (EPID) is a valuable imaging tool for verifying radiotherapy treatments. The treatment cannot be carried out without being sure of the patient's position and the associated deviations, so it is essential that its reliability must be as high as possible. In this work, it was explored real failure data in order to determine the reliability behavior of such devices and identify in which life stage the device is operating. With the analysis developed it was possible to identify the probability of failure of the EPID related to the number of treatments performed and based on that to have a sustainable decision- making process regarding the operation and maintenance of the EPID.
引用
收藏
页码:52 / 55
页数:4
相关论文
共 50 条
  • [21] Assement of the accuracy of treatment fields with electronic portal imaging device (EPID) in a breast irradiation
    Cetinayak, H. O.
    Gorken, I.
    Eyiler, F.
    Dag, N.
    Bayraktar, F.
    Sengunay, F.
    Yigitbasi, L.
    Ates, L.
    Alanyali, H.
    Kinay, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S278 - S279
  • [22] Modeling the temporal-spatial nature of the readout of an electronic portal imaging device (EPID)
    Abbasian, Parandoush
    McCowan, Peter M.
    Rickey, Daniel W.
    Van Uytven, Eric
    McCurdy, Boyd M. C.
    [J]. MEDICAL PHYSICS, 2020, 47 (10) : 5301 - 5311
  • [23] Transit Dosimetry for Verification of Dose Delivery Using Electronic Portal Imaging Device (EPID)
    Baek, T.
    Chung, E.
    Lee, S.
    Yoon, M.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 301 - 301
  • [24] Dosimetry Study On An Amorphous Silicon Electronic Portal Imaging Device(a-Si EPID)
    Wu, Q.
    Hu, Y.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2596 - +
  • [25] Verification of electron fields by means of EPID-method (electronic portal imaging device)
    Poser, A.
    Gaupp, S.
    Buchgeister, M.
    Paulsen, F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 : 108 - 109
  • [26] Analysis programme for EPID images for stability testing on medical linear catalysts after the DIN 6847-5 and the WINSTON-LUTZ-Test (EPID: electronic portal Imaging device)
    Griessbach, I
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 70 - 70
  • [27] A new approach for the pixel map sensitivity (PMS) evaluation of an electronic portal imaging device (EPID)
    Boriano, Alberto
    Lucio, Francesco
    Calamia, Elisa
    Russi, Elvio
    Marchetto, Flavio
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06): : 234 - 250
  • [28] QUALITY ASSURANCE OF ENHANCED DYNAMIC WEDGE (EDW) USING ELECTRONIC PORTAL IMAGING DEVICE (EPID)
    Narayanan, S.
    Arasu, K.
    Narayanan, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S235 - S235
  • [29] Radiotherapy delivery error detection with electronic portal imaging device (EPID)-based in vivo dosimetry
    Yang Xueying
    Geng Lisheng
    Huang David
    Li Kaiwen
    Zhuang Hongqing
    Cai Jing
    Yang Ruijie
    [J]. 中华医学杂志(英文版), 2023, 136 (08)
  • [30] TREATMENT QUALITY ASSESSMENT USING IN VIVO ELECTRONIC PORTAL IMAGING DEVICE (EPID) DOSIMETRY IN RADIOTHERAPY
    Fuangrod, Todsaporn
    Simpson, John
    Greer, Peter
    [J]. ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2016, 12 : 13 - 14