Reliability analysis of an Electronic Portal Imaging Device (EPID) of a linear accelerator

被引:0
|
作者
Gouveia, Clesia [1 ,2 ]
Sobral, Jose [1 ,3 ]
机构
[1] ISEL, Lisbon, Portugal
[2] Joaquim Chaves Saitde JCS, Lisbon, Portugal
[3] CENTEC, Lisbon, Portugal
关键词
EPID; reliability; failure; Weibull; DOSIMETRY;
D O I
10.1109/ENBENG58165.2023.10175354
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Electronic Portal Imaging Device (EPID) is a valuable imaging tool for verifying radiotherapy treatments. The treatment cannot be carried out without being sure of the patient's position and the associated deviations, so it is essential that its reliability must be as high as possible. In this work, it was explored real failure data in order to determine the reliability behavior of such devices and identify in which life stage the device is operating. With the analysis developed it was possible to identify the probability of failure of the EPID related to the number of treatments performed and based on that to have a sustainable decision- making process regarding the operation and maintenance of the EPID.
引用
收藏
页码:52 / 55
页数:4
相关论文
共 50 条
  • [1] The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID)
    Liu G.
    van Doorn T.
    Bezak E.
    [J]. Australasian Physics & Engineering Sciences in Medicine, 2004, 27 (3): : 111 - 117
  • [2] Imaging linear accelerator output using a high-speed scintillation based electronic portal imaging device (Hi-EPID)
    Ranade, Manisha
    Lynch, Bart
    Li, Jonathan
    Kim, Siyong
    Dempsey, James
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1811 - +
  • [3] Imaging linear accelerator startup using a high-speed scintillation based electronic portal imaging device (Hi-EPID)
    Ranade, M.
    Lynch, B.
    Li, J.
    Kim, S.
    Dempsey, J.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2612 - 2612
  • [4] PORTAL DOSE MEASUREMENT IN RADIOTHERAPY USING AN ELECTRONIC PORTAL IMAGING DEVICE (EPID)
    HEIJMEN, BJM
    PASMA, KL
    KROONWIJK, M
    ALTHOF, VGM
    DEBOER, JCJ
    VISSER, AG
    HUIZENGA, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11): : 1943 - 1955
  • [5] Evaluation of quality assurance phantom for electronic portal imaging device (EPID)
    Das, I.
    Cheng, C.
    Chopra, K.
    Misic, V.
    Schule, E.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2371 - 2372
  • [6] Quality assurance of linear accelerator: a comprehensive system using electronic portal imaging device
    Niyas, P.
    Abdullah, K. K.
    Noufal, M. P.
    Vysakh, R.
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (02) : 138 - 149
  • [7] Verification of radiosurgery target point alignment with an electronic portal imaging device (EPID)
    Dong, L
    Shiu, A
    Tung, S
    Boyer, A
    [J]. MEDICAL PHYSICS, 1997, 24 (02) : 263 - 267
  • [8] SIMPLE PROPOSAL FOR DOSIMETRY WITH AN ELEKTA IVIEWGTTM ELECTRONIC PORTAL IMAGING DEVICE (EPID)
    Liebich, J.
    Licher, J.
    Scherf, C.
    Kara, E.
    Koch, N.
    Roedel, C.
    Ramm, U.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S419 - S419
  • [9] Using an electronic portal imaging device (EPID) for routine geometrical LINAC verifications
    Bejarano, M. Benito
    Beltran, F. Saez
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S253 - S254
  • [10] Electronic portal imaging device (EPID) based on a novel camera with avalanche multiplication
    Pang, G
    Zhao, W
    Luhta, R
    Rowlands, JA
    [J]. PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 195 - 201